| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Ultrasonic Flow Meter |
|---|---|
| Brand Name: | Endress+Hauser |
| Certification: | CE |
| Place of Origin: | Switzerland |
| MOQ: | 1PCS |
| Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability: | 1000 Piece/Pieces per Week negotiable |
| Delivery Time: | 5-8 work days |
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Process temperature: | 0 to 120°C (32 to 248 °F) |
| Process pressure: | max. 16 bar at 20 °C (232 psi at 68 °F) |
| Ex certification: | Non-hazardous area |
| Ingress protection: | Sensor: IP67, IP69 optional |
| Company Info. |
| Xi'an Kacise Optronics Co.,Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
"Specs at a glance
Max. measurement error
Acoustic density: ±0.01g/cm³
Temperature: ±0.5K
Sound velocity: +-2m/s
Measuring range
Concentration According to concentration app data sheet, maximum 0
to 100 %
Sound velocity 600 to 2000 m/s
Temperature, maximum 0 to +100 °C (32 to +212 °F)
Acoustic density 0.7 to 1.5 g/cm³
Medium temperature range
0 to 120°C (32 to 248 °F)
Process temperature
0 to 120°C (32 to 248 °F)
Max. process pressure
max. 16 bar at 20 °C (232 psi at 68 °F)
Process pressure
max. 16 bar at 20 °C (232 psi at 68 °F)
Wetted materials
Stainless steel1.4404 (316L)" "Field of application
Teqwave H is ideal for real-time liquid analysis in hygienic
applications like spirits and soft drink production. End customers
and equipment manufacturers value its highly accurate in situ
concentration measurement and hygienic design. Teqwave reduces the
operational expenditure by monitoring various measuring parameters
at once. Match your Teqwave transmitter perfectly to your
production needs by flexible definition and extension of your
application range.
The acoustic waveguide measures precisely and reliably, even the smallest changes are detected
Continuous quality monitoring of beverages and in cleaning processes
Device properties
Nominal diameter: DN 25 (1"")
Sensor housing made of stainless steel (3-A, EHEDG)
Accurate and independent of flow profile
Industry-compliant, easy installation via DIN rail and pipe mounting set
3.5"" TFT color touch screen or LED indication
4-20 mA, Modbus TCP" "Benefits
High accuracy and repeatability – concentration calculation with
latest algorithms
Fulfilment of hygienic requirements – easily cleanable full-bore sensor
Full transparency – constant monitoring of product quality without sampling
Highest process safety – reliable metering due to robust, maintenance-free sensor
Customized usage – innovative application concept, expendable for changing measuring tasks
Simplified process control – user-friendly operation and clear status visualization
Local data backup – integrated data storage for measured values up
to 7,5 years" "Measuring principle
Ultrasonic concentration
Product headline
Inline device with best-in-class hygienic design – plug and play
for food and beverage processes.
High accuracy and repeatability – concentration calculation with
latest algorithms.
Continuous quality monitoring of beverages and in cleaning
processes.
Sensor features
Fulfilment of hygienic requirements – easily cleanable full-bore
sensor. Full transparency – constant monitoring of product quality
without sampling. Highest process safety – reliable metering due to
robust, maintenance-free sensor.
Nominal diameter: DN 25 (1""). Accurate and independent of flow
profile. Sensor housing made of stainless steel (3-A, EHEDG).
Transmitter features
Customized usage – innovative application concept, expendable for
changing measuring tasks. Simplified process control –
user-friendly operation and clear status visualization. Local data
backup – integrated data storage for measured values up to 7,5
years.
Industry-compliant, easy installation via DIN rail. 3.5"" TFT color
touch screen or LED indication. 4-20 mA, Modbus TCP.
Nominal diameter range
DN 25 (1“ DIN and ANSI)
Measured variables
Concentration, sound velocity, temperature, acoustic density,
dispersion
Max. measurement error
Acoustic density: ±0.01g/cm³
Temperature: ±0.5K
Sound velocity: +-2m/s
Measuring range
Concentration According to concentration app data sheet, maximum 0
to 100 %
Sound velocity 600 to 2000 m/s
Temperature, maximum 0 to +100 °C (32 to +212 °F)
Acoustic density 0.7 to 1.5 g/cm³
Design
Inline, hygienic
Material
Sensor material: Stainless steel 1.4404 (316L)
Transmitter housing material: Anodized aluminium and glas, optional
1.4301 and plastic
Process temperature
0 to 120°C (32 to 248 °F)
Process pressure
max. 16 bar at 20 °C (232 psi at 68 °F)
Ex certification
Non-hazardous area
Ingress protection
Sensor: IP67, IP69 optional
Transmitter: IP40, optional IP67
Display/Operation
LED status indication
TFT color touch display
Outputs
Modbus TCP, Relay (AC 50V, DC30V 1A), 4-20mA/0 to 10V Analog output
Power supply
DC 24V +-20%
Product safety
CE, UKCA, RCM"
|