| Brand Name: | UC | 
| Model Number: | UC8512C+2xUC88201 | 
| Place of Origin: | CHINA | 
| MOQ: | 1pcs | 
| Price: | negotiate a price | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 5pcs+per month | 
| Delivery Time: | 20 work days | 
| Packaging Details: | Carton | 
| Wavelength resolution: | 1.0 pm | 
| Absolute wavelength accuracy: | ±10 pm, Typ. ±5 pm | 
| Power stability: | ±0.005dB (15Min) ±0.05 dB ( 24 hours) | 
| Power linearity: | ± 0.3 dB | 
| Power measuring range: | +5 dBm to -85 dBm | 
| Operating temperature: | 0°C ~ +45°C | 
| Storage temperature: | −40°C ~ +80°C | 
| Company Info. | 
| Guangzhou UC Instruments., Co. Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Laser scanning spectrometer with output power 13 dBm Easy to use
Specification
| Model # | UC8512C+UC88201 | 
| Adjustable laser light source | |
| Wavelength range | 1525.00 ~ 1568.00 nm | 
| Output Power | 13 dBm | 
| Wavelength resolution | 1.0 pm | 
| Absolute wavelength accuracy | ±10 pm, Typ. ±5 pm | 
| Relative wavelength accuracy | ± 5 pm, Typ. ±2 pm | 
| Wavelength repeatability | ± 3 pm, typ. ±1 pm | 
| Wavelength stability | ±5 pm (typ., 24 hrs at Constant Temperature) | 
| Tuning speed | ≤ 2 ms per step | 
| Power stability | ±0.005dB (15Min) ±0.05 dB ( 24 hours) | 
| Power repeatability | ± 0.05 dB | 
| Power linearity | ± 0.3 dB | 
| Power flatness | 0.3 dB; Typical values 0.05dB. | 
| Side mode rejection rate | ≥ 40 dBm | 
| Relative noise intensity | Typical values < -135 dB | 
| Optical power meter | |
| Wavelength range | 850 nm to 1625 nm | 
| Power measuring range | +5 dBm to -85 dBm | 
| Precision of power | < ± 4% | 
| Power repeatability | < 0.1 dB | 
| Scanning function: equipped with DWDM/Isolator/GFF device scanning software | |
| Scanning mode | Fast adjustable laser spectral scanning | 
| resolution ratio | 1 pm | 
| precision | 5 pm | 
| Power display | Peak power display | 
| Central wavelength function | Central wavelength and 3dB bandwidth display | 
| Reference function | Reference test | 
| Power adapter power | AC 100 ~ 240 V , 48 - 66 Hz,100 VA max. | 
| display | PC control interface | 
| Optical output interface | FC/PC connector | 
| Communication interface | USB / RS232 interface | 
| Storage temperature | −40°C ~ +80°C | 
| Operating temperature | 0°C ~ +45°C | 
| Dimensions | 245 mm W, 105 mm H, 320 mm D | 
| Weight | 3.0kg | 

|   | 
 UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                                                    
                        
                        
                        
                                                            UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                    
                        
                     Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                                                    
                        
                        
                        
                                                            Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                    
                        
                     1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                                                    
                        
                        
                        
                                                            1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                    
                        
                     RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                                                    
                        
                        
                        
                                                            RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                    
                        
                     SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                                                    
                        
                        
                        
                                                            SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                    
                        
                     60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                                                    
                        
                        
                        
                                                            60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                    
                        
                     10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                                                    
                        
                        
                        
                                                            10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                    
                        
                     The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                                                    
                        
                        
                        
                                                            The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                    
                        
                     Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                    
                        
                     Dual Wavelength Insert / Return Loss Meter With LCD Display
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insert / Return Loss Meter With LCD Display