| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Optical Return Loss Meter | 
|---|---|
| Brand Name: | YOUCii | 
| Model Number: | UC8512+2xUC88201 | 
| Place of Origin: | CHINA | 
| MOQ: | 1pcs | 
| Price: | negotiate a price | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 5pcs+per month | 
| Delivery Time: | 20 work days | 
| Packaging Details: | Carton | 
| Wavelength range(nm): | 1525.00 ~ 1568.00 | 
| Absolute wavelength accuracy(pm): | ±10 pm, Typ. ±5 pm | 
| Relative wavelength accuracy(pm): | ± 5 pm, Typ. ±2 pm | 
| Tuning speed(ms): | ≤ 2 ms per ste | 
| Power repeatability(dB): | ± 0.05 | 
| Relative noise intensity(dB): | Typical value < -135 | 
| Output power(dBm): | 13 | 
| warranty: | 1 year | 
| Company Info. | 
| Guangzhou UC Instruments., Co. Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
Specification
| Model # | UC8512C+UC88201 | 
| Adjustable laser light source | |
| Wavelength range | 1525.00 ~ 1568.00 nm | 
| Output Power | 13 dBm | 
| Wavelength resolution | 1.0 pm | 
| Absolute wavelength accuracy | ±10 pm, Typ. ±5 pm | 
| Relative wavelength accuracy | ± 5 pm, Typ. ±2 pm | 
| Wavelength repeatability | ± 3 pm, typ. ±1 pm | 
| Wavelength stability | ±5 pm (typ., 24 hrs at Constant Temperature) | 
| Tuning speed | ≤ 2 ms per step | 
| Power stability | ±0.005dB (15Min) ±0.05 dB ( 24 hours) | 
| Power repeatability | ± 0.05 dB | 
| Power linearity | ± 0.3 dB | 
| Power flatness | 0.3 dB; Typical values 0.05dB. | 
| Side mode rejection rate | ≥ 40 dBm | 
| Relative noise intensity | Typical values < -135 dB | 
| Optical power meter | |
| Wavelength range | 850 nm to 1625 nm | 
| Power measuring range | +5 dBm to -85 dBm | 
| Precision of power | < ± 4% | 
| Power repeatability | < 0.1 dB | 
| Scanning function: equipped with DWDM/Isolator/GFF device scanning software | |
| Scanning mode | Fast adjustable laser spectral scanning | 
| resolution ratio | 1 pm | 
| precision | 5 pm | 
| Power display | Peak power display | 
| Central wavelength function | Central wavelength and 3dB bandwidth display | 
| Reference function | Reference test | 
| Power adapter power | AC 100 ~ 240 V , 48 - 66 Hz,100 VA max. | 
| display | PC control interface | 
| Optical output interface | FC/PC connector | 
| Communication interface | USB / RS232 interface | 
| Storage temperature | −40°C ~ +80°C | 
| Operating temperature | 0°C ~ +45°C | 
| Dimensions | 245 mm W, 105 mm H, 320 mm D | 
| Weight | 3.0kg | 
Rear Panel of the host

The power supply requirements
The UC8512C+UC88201 complies with overvoltage Level II regulations. The operating
voltage is 100 ~ 240V AC voltage, the frequency range is 48 ~ 66Hz,
the operating voltage is 115V, the maximum consumption current is
230mA; When the operating voltage is 230V, the maximum consumption
current is 120mA.
USB port
The USB interface is a standard 4-core B-type interface, which can
be connected to UC8512C+UC88201 and PC, and the instrument can be controlled by monitoring
software.
USB connection cable
The length of the USB cable cannot exceed 5 m. Otherwise, only a
third-party USB peripheral extender can be used. Generally, the
maximum extension length can reach 50 m.
RS232 serial port
The serial port parameters of the instrument are set to a fixed
value. The serial port parameter Settings of the computer must
match the instrument parameter Settings.

FAQ
Q: Are you a factory manufacturer?
A: Yes we are manufacturer with 13 years experience in this
industry and supplied many good quality products.
Q: Where is your main market?
A: Asia, Europe, America, Middle-East, Africa and other countries
and regions.
Q:What is your minimum order quantity (MOQ)?
A: As a standard policy, we accept MOQ of 1set, and mixed items
available, it still needs to confirm with our sales according to
different product lines.
Q: Can I customize the size and color of the case?
A: Yes. We can discuss it .
Q: Can I buy some samples first before main orders? Is the sample
fee refundable?
A: Yes, sample fee and shipment fee should be paid in advance .
Q: How long is the Production Lead Time?
A: 5 days for stock products, different products have different
delivery times, according to the actual situation.
|   | 
 UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                                                    
                        
                        
                        
                                                            UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                    
                        
                     1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                                                    
                        
                        
                        
                                                            1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                    
                        
                     Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                                                    
                        
                        
                        
                                                            Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                    
                        
                     RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                                                    
                        
                        
                        
                                                            RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                    
                        
                     SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                                                    
                        
                        
                        
                                                            SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                    
                        
                     60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                                                    
                        
                        
                        
                                                            60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                    
                        
                     10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                                                    
                        
                        
                        
                                                            10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                    
                        
                     The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                                                    
                        
                        
                        
                                                            The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                    
                        
                     Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                    
                        
                     Dual Wavelength Insert / Return Loss Meter With LCD Display
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insert / Return Loss Meter With LCD Display