Heat Dissipation In-Row Precision Air Conditioners R407C Refrigerant

Categories In Row Air Conditioning Unit
Brand Name: COOLNET
Model Number: CR012 CR040
Certification: CE,ISO
Place of Origin: CHINA
MOQ: 1set
Price: 1800-30000USD
Payment Terms: T/T, L/C
Supply Ability: 300 PCS PER MONTG
Delivery Time: 10-25 working days
Packaging Details: Packed in plywooden case, standard export package
Cooling capacity: 20-50KW (per unit)
Mounting: Floor Standing Units
Type: InRow AC Unit
Operating voltage: 380/400 VAC,230 VAC,220V
Warranty: 1 Year,12 month with no artificial damage
Product name: Inrow Type Precision air conditioning Units
Refrigerant: R410A/R407C
Application: Data Center, IT room , Modular Data Center, Computer room, Cold/hot aisle
Color: Black/Grey/Other custom colors
Fan type: EC fan
Power: 3N-380V-50Hz,220v/50hz/60hz
Airflow: Front flow/Down ward flow
Voltage: 380v/220v,220V/380V,380V/415V
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Heat Dissipation In-Row Precision Air Conditioners R407C Refrigerant

Heat Dissipation In-Row Precision Air Conditioners For Providing Constant Precise Environment


Product Introduction


XRow series in-row air conditioners are air conditioners developed for the cooling of server racks in small, medium and large communication data centers. It is especially suitable for micro-module systems with closed hot and cold aisles. The Coolnet in-row air conditioners features a row-oriented cooling architecture, with each CRAC unit dedicated to cooling a row of server racks. CRAC units can be installed between racks, overhead, or under the floor. Airflow paths are shorter and more clearly defined than room-based cooling. This reduces the required CRAC fan power, increasing efficiency.


Application Range

  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction

Air Supply Method


Structure and Componenets

EVO intelligent control system

Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;


DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability


Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Advantages and Features


The advantages mainly lie in specific applications, such as modular data centers, which do not have many advantages in ordinary computer rooms.


(1) Near-end refrigeration: Close to the heat source for refrigeration, with the design of hot and cold passages, to further optimize the indoor airflow organization, reduce the overall PUE value of the computer room, and improve the cooling efficiency.


(2) High energy efficiency ratio: high return air temperature and high heat output equipment have a high matching degree, which makes the unit energy efficiency ratio very good, low energy consumption and low operating cost.


(3) High reliability: ultra-long life design, 24 hours and 365 days of uninterrupted operation, the average design life is about 10 years.


(4) Adopt DC inverter compressor: dynamic refrigeration, high efficiency, low consumption, high adaptability; Equipped with EC centrifugal fan, N+1 redundancy design, automatically adjust the air supply volume according to the load of the computer room.


(5) Size:The size of the standard rack is consistent with the appearance of the cabinet, beautiful and easy to expand.

Technical Parameter


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates


Factory Details

400VAC Data Center Precision Air Conditioner Closer To Server Rack 4


Delivery & Packing


Cases



China Heat Dissipation In-Row Precision Air Conditioners R407C Refrigerant factory
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0