| Categories | In Row Air Conditioning Unit | 
|---|---|
| Brand Name: | COOLNET | 
| Model Number: | CYA,M08,CR012 | 
| Certification: | CE,ISO | 
| Place of Origin: | CHINA | 
| MOQ: | 1set | 
| Price: | 1800-30000USD | 
| Payment Terms: | T/T, L/C | 
| Supply Ability: | 300 PCS PER MONTG | 
| Delivery Time: | 10-25 working days | 
| Packaging Details: | Packed in plywooden case, standard export package | 
| Cooling capacity: | 20-50KW | 
| Condition: | New | 
| Mounting: | Floor Standing | 
| Type: | Inrow Unit | 
| After-sales service provided: | Engineers available to service machinery overseas | 
| Operating voltage: | 380/400 VAC,230 VAC,220V | 
| Warranty: | 1 Year | 
| Product name: | Data Center Air Conditioning In - Row Cooling | 
| Refrigerant: | R22(R407C/R410A) | 
| Application: | Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity | 
| Color: | Black/Grey white/other custom colors | 
| Airflow: | 2000~50000 m3/h | 
| Company Info. | 
| Hefei Coolnet power Co., ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
400VAC Data Center Precision Air Conditioner Closer To Server Rack
| Product Introduction Constant temperature and humidity air conditioning units are used widely, from daily food,textile, to representatives of state-of-the-art aerospace, bio-engineering to emerge from the rapid development of the electronics industry, chemical industry from steel to precision instrument manufacturing, from hospital wards to the preparation of pharmaceutical ,all walks of life can be seen everywhere. Due to the complexity and diversity of applications, the constant temperature and humidity unit in the structure, precision air handling with the ever-changing requirements, which requires the unit manufacturer must have the ability to respond to constant environmental design. Applications 
 |  | 
|  | |
Features of IN-Row Air Conditioner
|  | EVO Control System ■ Graphic display, including the running status and the
temperature/humidity of the inlet/outlet air ■ Advanced team work function, up to 32 units and easy to set
network ■ Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS
with SMS ■ Standard communication protocol, optional customized
specifications Electronically Commutated Compressor EC Fan Electronic Expansion Valve Options | 
Technical Parameter
| Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A | 
| Air supply | Front/Side | Front/Side | Front | Front | Front | 
| Power supply | 380VAC/3Ph/50Hz | ||||
| Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 | 
| Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 | 
| Compressor | |||||
| Refrigerant | R410A | ||||
| Quantity | 1 | ||||
| Fan | |||||
| Fan type | EC Centrifugal fan | ||||
| Quantity | 4 | 5 | 2 | 3 | 3 | 
| Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 | 
| Heater | |||||
| Heat type | PTC | ||||
| Capacity-KW | 2 | 3 | 6 | 6 | 6 | 
| Humidification | |||||
| Capacity-KW | 1 | 1.5 | 3 | 3 | 3 | 
Certificates

Factory Details

Delivery & Packing

Cases

|   | 
 Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers
                                                                                    
                        
                        
                        
                                                            Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers
                                                    
                        
                     2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room
                                                                                    
                        
                        
                        
                                                            2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room
                                                    
                        
                     Row Based PACU Air Conditioning Unit Place Close To The Heat Source
                                                                                    
                        
                        
                        
                                                            Row Based PACU Air Conditioning Unit Place Close To The Heat Source
                                                    
                        
                     In Row Air Conditioning Unit  Data Center Precision Air Conditioner
                                                                                    
                        
                        
                        
                                                            In Row Air Conditioning Unit  Data Center Precision Air Conditioner
                                                    
                        
                     Data Center Rack 23.5KW Precision In Row Cooling Unit
                                                                                    
                        
                        
                        
                                                            Data Center Rack 23.5KW Precision In Row Cooling Unit
                                                    
                        
                     EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
                                                                                    
                        
                        
                        
                                                            EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
                                                    
                        
                     Computer Room Server Rack Cooling Unit Row-Based Cooling
                                                                                    
                        
                        
                        
                                                            Computer Room Server Rack Cooling Unit Row-Based Cooling
                                                    
                        
                     HVAC Data Centre R410A In Row Air Conditioning Unit
                                                                                    
                        
                        
                        
                                                            HVAC Data Centre R410A In Row Air Conditioning Unit
                                                    
                        
                     300mm Air Cooled In Row Air Conditioning Unit For Server Room
                                                                                    
                        
                        
                        
                                                            300mm Air Cooled In Row Air Conditioning Unit For Server Room
                                                    
                        
                     25kW In Row Air Conditioning Unit , IT Room Air Conditioner Floor Standing
                                                                                    
                        
                        
                        
                                                            25kW In Row Air Conditioning Unit , IT Room Air Conditioner Floor Standing