| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Flange load cell | 
|---|---|
| Brand Name: | Forsentek | 
| Model Number: | FFG | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 1pc | 
| Payment Terms: | T/T,Western Union or Paypal | 
| Supply Ability: | 2970pcs/month | 
| Delivery Time: | 3~25 working days | 
| Packaging Details: | Carton | 
| Type: | Cylindrical Load Cell | 
| Capacity: | 20N 50N 100N 200N 500N 1000N 2000N | 
| Usage: | Force measurement | 
| Force measurement direction: | Tension and compression | 
| Output: | Analog Sensor | 
| Mounting: | Flange to flange | 
| Company Info. | 
| Forsentek Co., Limited | 
| View Contact Details | 
| Product List | 
Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor
Miniature Flange-to-Flange Tension Compression Force Sensor FFG is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of rated output.Miniature force sensor FFG offers 0-20N / 0-50N / 0-100N / 0-200N / 0-500N / 0-1kN / 0-2kN seven rated capacities to choose from, model FFG can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Miniature Load Cell FFG offers a perfect mixture for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification,and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.

Dimensions(Unit in "mm")

| Ordering code | Measurement Range | Force direction | 
| FFG-20N | 0-20N / 0-2kgf | Tension/compression | 
| FFG-50N | 0-50N / 0-5kgf | |
| FFG-100N | 0-100N / 0-10kgf | |
| FFG-200N | 0-200N / 0-20kgf | |
| FFG-500N | 0-500N / 0-50kgf | |
| FFG-1kN | 0-1000N / 0-100kgf | |
| FFG-2kN | 0-2000N / 0-200kgf | 
Specifications
| Capacity | 20N / 50N / 100N / 200N / 500N / 1kN / 2kN | 
| Rated output | 2.0 mV/V | 
| Excitation | 3-15V | 
| Zero balance | ±0.05mV/V | 
| Nonlinearity | ±0.1% R.O. | 
| Hysteresis | ±0.1% R.O. | 
| Nonrepeatability | ±0.05% R.O. | 
| Creep(5min) | ±0.05% R.O. | 
| Safe overload | 150% F.S. | 
| Ultimate overload | 200% F.S. | 
| Compensated temperature | -10...+40oC | 
| Operating temperature | -20...+60oC | 
| Temperature shift zero | ±0.02% R.O./oC | 
| Temperature shift span | ±0.02% R.O./oC | 
| Input resistance | 350±30 ohms | 
| Output resistance | 350±5 ohms | 
| Insulation resistance | >2000M ohms | 
| Ingress protection | IP62 | 
| Material of element | Stainless steel | 
| Cable | Ø3*3000mm 4-core shielded | 
| Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- | 
A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within
0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: Flange Load Cell FFG-500N with 2.0mV/V sensitivity powered by 5V DC,the output
range is -10mV...+10mV(Tension and compression).
Example two: Tension Compression Load Cell FFG-200N with 2.0mV/V sensitivity powered by 10V DC,the output
range is -20mV...+20mV(Tension and compression).
A signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.
Example: FFG-500N working with -5-5V amplifier,the Force-Voltage relationship will be 0-500N compression load VS 0-5V output, 0-500N tension load VS 0-(-5V) output,when you get 3V output,it means the current load is 300N compression force,when you get -2V output,it means the current load is 200N tension force,and so on.
Flange Type Load Cell 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Transducer

|   | 
 Flange Type Load Cell 20kN 10kN 5kN 2kN 1kN 500N 200N Flange Mounted Force Transducer
                                                                                    
                        
                        
                        
                                                            Flange Type Load Cell 20kN 10kN 5kN 2kN 1kN 500N 200N Flange Mounted Force Transducer
                                                    
                        
                     Miniature Flange-to-Flange Load Cell 1kg 2kg 5kg 10kg 20kg Compression Weight Sensor
                                                                                    
                        
                        
                        
                                                            Miniature Flange-to-Flange Load Cell 1kg 2kg 5kg 10kg 20kg Compression Weight Sensor
                                                    
                        
                     Flange-to-Flange Force Transducer 60kN 50kN 40kN 30kN 20kN 10kN 5kN 3kN
                                                                                    
                        
                        
                        
                                                            Flange-to-Flange Force Transducer 60kN 50kN 40kN 30kN 20kN 10kN 5kN 3kN
                                                    
                        
                     Flange Style Force Sensor 20kN 10kN 5kN 3kN 2kN Tension Compression Transducer
                                                                                    
                        
                        
                        
                                                            Flange Style Force Sensor 20kN 10kN 5kN 3kN 2kN Tension Compression Transducer
                                                    
                        
                     Flange-to-Flange Load Cell 2000kg 1000kg 500kg 200kg 100kg 50kg 20kg
                                                                                    
                        
                        
                        
                                                            Flange-to-Flange Load Cell 2000kg 1000kg 500kg 200kg 100kg 50kg 20kg
                                                    
                        
                     200kg 500kg 1ton 2 ton 3ton 5 ton 6ton Load Cell With Flange Mounting
                                                                                    
                        
                        
                        
                                                            200kg 500kg 1ton 2 ton 3ton 5 ton 6ton Load Cell With Flange Mounting
                                                    
                        
                     Flange Type Load Cell 10 lb 20 lbf 50lb 100 lbf 200lb 450 lb Flange Mounted Force Sensor
                                                                                    
                        
                        
                        
                                                            Flange Type Load Cell 10 lb 20 lbf 50lb 100 lbf 200lb 450 lb Flange Mounted Force Sensor
                                                    
                        
                     Flange-to-Flange Load Cell 4.5klb 2k lb 1klb 450 lb 220 lb 110 lb Flange Type Force Sensor
                                                                                    
                        
                        
                        
                                                            Flange-to-Flange Load Cell 4.5klb 2k lb 1klb 450 lb 220 lb 110 lb Flange Type Force Sensor
                                                    
                        
                     High Range Flange Load Cell 300kN 500kN 1000kN 2000kN 3000kN 5000kN
                                                                                    
                        
                        
                        
                                                            High Range Flange Load Cell 300kN 500kN 1000kN 2000kN 3000kN 5000kN
                                                    
                        
                     Flange Mounted Load Cell 50ton 100 ton 200ton 300 ton 500 ton Compression Load cell
                                                                                    
                        
                        
                        
                                                            Flange Mounted Load Cell 50ton 100 ton 200ton 300 ton 500 ton Compression Load cell