2DI2DO Wireless Modbus RTU Wireless Digital I O Module , Wireless Pump ON OFF Control 2km
1. LS-RDIO series module general introduction
LS-RDIO Modbus RTU is an industrial controller designed by Lensen Technology. It supports point to point, point to multi-points wireless DI, DO collection and control. This transceiver has the advantage of easy installation, no program required, no communication fee. It is reliable and cost-effective substitution for rail signal cable, slip ring signal wire.
LS-RDIO0202 has 2 inputs 2 relay outputs and 1 RS485 (wireless RS485 is customized). Power output we have 2 versions, one is 100mW for 1km LOS control distance, and another one is 1W for 3km LOS control distance
2. Application Field
LS-RDIO series I/O module is widely used in industry automation like factory central data process, pump control, tank level monitoring, Conveyor Control,oil monitoring, mining machinery, environment monitoring equipment, lifting devices, robots control, filling machine, mixing equipment, logistic line, AGV etc.
3. LS-RDIO0202 Parameter
| Parameter | |
| Power output: | 1W (or 100mW version) | 
| Power supply: | 9V-30V (usually choose 24V DC or 12V DC) | 
| Control distance: | 3km (or 1km version) | 
| Baud rate: | 1200bps | 
| Receiving sensibility: | -123dBm@1200bps, -118dbm(9600bps) | 
| Networking | |
| Networking: | Point to point and point to multipoint | 
| Protocol: | Modbus RTU protocol | 
| Port Description | |
| Input: | 2 active inputs (passive customize), isolated | 
| Output: | 2 passive relay outputs, isolated contact max load AC250V/5A,DC30V/5A (active outputs 0-5V customize) | 
| Communication port | RS485 (wireless RS485 customize) | 
| Current | |
| Transmit current: | <600mA (or 100mA version) | 
| Receiving current: | <50mA (or 20mA version) | 
| General | |
| Frequency: | 433MHz, 400, 450, 470 or other band | 
| Channel No: | 16 channels, can change via DIP switch | 
| Physical Properties | |
| Dimension: | 115×90×40(mm) | 
| Antenna Connector: | SMA,vehicle antenna with 1.5m cable | 
| Temperature: | -35℃~+75℃( industrial) | 
| Mounting method: | Standard 3.5 inch industrial guild rail | 
4. How to connect

Application


Wireless pump ON-OFF control

One master to 4 salves

| Master | Slave | Input and Output Correspondence | 
| A(DI1-DI2) | B1(DO1-DO2) | DI1-DI2 of A control DO1-DO2 of B1 | 
| A(DI3-DI4) | B2(DO1-DO2) | DI3-DI4 of A control DO1-DO2 of B2 | 
| A(DI5-DI6) | B3(DO1-DO2) | DI5-DI6 of A control DO1-DO2 of B3 | 
| A(DI7-DI8) | B4(DO1-DO2) | DI7-DI8 of A control DO1-DO2 of B4 | 
| A(DO1-DO2) | B1(DI1-DI2) | DO1-DO2 of A controlled by DI1-DI2 of B | 
| A(DO3-DO4) | B2(DI1-DI2) | DO3-DO4 of A controlled by DI1-DI2 of B2 | 
| A(DO5-DO6) | B3(DI1-DI2) | DO5-DO6 of A controlled by DI1-DI2 of B3 | 
| A(DO7-DO8) | B4(DI1-DI2) | DO7-DO8 of A controlled by DI1-DI2 of B4 | 
| Notes: A and B should use the same channel | ||
|   | 
 433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF 2km
                                                                                    
                        
                        
                        
                                                            433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF 2km
                                                    
                        
                     2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves
                                                                                    
                        
                        
                        
                                                            2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves
                                                    
                        
                     Pump ON-OFF Control System According the Float Switch High Or Low Level
                                                                                    
                        
                        
                        
                                                            Pump ON-OFF Control System According the Float Switch High Or Low Level
                                                    
                        
                     2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
                                                                                    
                        
                        
                        
                                                            2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
                                                    
                        
                     16DI 16DO Wireless I O Module PLC Wireless Controller 2km Wireless ON OFF Control
                                                                                    
                        
                        
                        
                                                            16DI 16DO Wireless I O Module PLC Wireless Controller 2km Wireless ON OFF Control
                                                    
                        
                     Digital Input Wireless Modbus RTU 2km Wireless Pump Control 868MHz Wireless Lora Module
                                                                                    
                        
                        
                        
                                                            Digital Input Wireless Modbus RTU 2km Wireless Pump Control 868MHz Wireless Lora Module
                                                    
                        
                     Lora Wireless Modbus RTU
                                                                                    
                        
                        
                        
                                                            Lora Wireless Modbus RTU
                                                    
                        
                     UHF Wireless Modbus RTU I/O Module 8DI 8DO RTU Module 2km PLC 8 Digital Inputs
                                                                                    
                        
                        
                        
                                                            UHF Wireless Modbus RTU I/O Module 8DI 8DO RTU Module 2km PLC 8 Digital Inputs
                                                    
                        
                     433MHz Wireless Modbus RTU
                                                                                    
                        
                        
                        
                                                            433MHz Wireless Modbus RTU
                                                    
                        
                     RS485 Wireless Modbus RTU PLC Remote Control I/O Mirroring For Stacker / Reclaimer
                                                                                    
                        
                        
                        
                                                            RS485 Wireless Modbus RTU PLC Remote Control I/O Mirroring For Stacker / Reclaimer