| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Wireless Modbus RTU | 
|---|---|
| Brand Name: | Lensen | 
| Model Number: | LS-RDIO0808 | 
| Place of Origin: | China | 
| MOQ: | 2pcs | 
| Price: | Negotiation | 
| Payment Terms: | T/T, Western Union | 
| Supply Ability: | 6000pcs/month | 
| Delivery Time: | 2-7 days | 
| Packaging Details: | standard carton | 
| Frequency: | 433 | 
| Power output: | 1W | 
| Distance: | 2-3km LOS | 
| Input: | 8 digital inputs | 
| Output: | 8 relay outputs | 
| Protocol: | Modbus RTU | 
| Company Info. | 
| Shenzhen Qianhai Lensen Technology Co., Ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
UHF Wireless I/O Module 8DI 8DO Wireless PLC 2km ON-OFF control
1. LS-RDIO0808 general introduction
This is a 8DI8DO wireless RTU
It has 8 digital input, 8 relay output
There is a 1W RF module inside, it's OK to control 2km
2. Application Field
LS-RDIO series I/O module is widely used in industry automation
like factory central data process, pump control, oil monitoring,
mining machinery, environment monitoring equipments, lifting
devices, robots control, filling machine, mixing equipments,
logistic line, AGV etc.
Conveyor Control
Control a conveyor motor remotely
Remote Control Relay
Use dry contact inputs to control a remote relay.
Problem Notification
Save time in large facilities by activating an overhead
notification light when a problem occurs, letting the supervisor
know exactly where to go.
Dust Suppression
Use wireless I/O module to operate your dust
Data Logging
Wirelessly acquire and log various data from a remote location
using our analog I/O module
Stacker Control
Start and stop your stacker/reclaimir. Connect PLC in control
center with stacker and reclaimer.
Proximity Detection
Mount a transmitter with adjustable range on heavy equipment, mount
a receiver in a “blind spot,” and then set up the receiver to sound
an alarm or turn on a light whenever the equipment is operating in
the area.
Chemical Level Monitoring
Monitor water chlorination or other chemicals remotely.
Traffic Signals
Avoid having to lay new wire by using wireless transmitters and
receivers to control traffic signs such as “Railroad Crossing
Ahead” when a train is present.
Grain Elevators
Our wireless transmitters and receivers can be used to monitor
grain elevator conditions or control different functions. To
collect RS485 data. To monitor temperature and humidity in Grain.
Freight Loading
Digital I/O module for crane control and analog I/O module to send
the load information wirelessly to another location.
3. Parameter
| Parameter | |
| Power output: | 1W or 100mW version | 
| Power supply: | 9V-30V (usually choose 24V DC or 12V DC) | 
| Control distance: | 3km or (1km version) | 
| Baud rate: | 1200bps | 
| Receiving sensibility: | -123dBm@1200bps, -118dbm(9600bps) | 
| Networking | |
| Networking: | Point to point and point to multipoint | 
| Port Description | |
| Input: | 8 active DI (passive customized) | 
| Output: | 8 relay passive outputs, | 
| Communication port | RS485 (wireless RS485 customize) | 
| Current | |
| Transmit current: | <600mA (or 100mA version) | 
| Receiving current: | <50mA (or 20mA version) | 
| General | |
| Frequency: | 433MHz, 400, 450, 470 or other band | 
| Channel No: | 16 channels,can change via DIP switch | 
| Physical Properties | |
| Dimension: | 145×90×40(mm) | 
| Antenna Connector: | SMA,vehicle antenna with 1.5m cable | 
| Temperature: | -35℃~+75℃( industrial) | 
| Mounting method: | Standard 3.5 inch industrial guild rail | 
4. How to use wireless I/O
5. Application diagram examples
One master to 8 salves

Remarks:
| Master | Salve | Input and control correspondence | 
| A(DI1) | B1(DO1) | DI1 of A control DO1 of B1 | 
| A(DI2) | B2(DO1) | DI2 of A control DO1 of B2 | 
| A(DI3) | B3(DO1) | DI3 of A control DO1 of B3 | 
| A(DI4) | B4(DO1) | DI4of A control DO1 of B4 | 
| A(DI5) | B5(DO1) | DI5 of A control DO1 of B5 | 
| A(DI6) | B6(DO1) | DI6 of A control DO1 of B6 | 
| A(DI7) | B7(DO1) | DI7 of A control DO1 of B7 | 
| A(DI8) | B8(DO1) | DI8 of A control DO1 of B8 | 
| A(DO1) | B1(DI1) | DO1 of A is controlled by DI1 of B1 | 
| A(DO8) | B8(DI1) | DO8 of A is controlled by DI1 of B8 | 
| Note: module A and B should use the same channel; | ||
To communicate with PC/PLC

|   | 
 Wireless I O Module Pump ON OFF Control 2DI2DO PLC Wireless Pump Control / Relay / Valve
                                                                                    
                        
                        
                        
                                                            Wireless I O Module Pump ON OFF Control 2DI2DO PLC Wireless Pump Control / Relay / Valve
                                                    
                        
                     10DI 10DO Wireless Modbus RTU 10 Digital Inputs 10 Relay Outputs 2km Wireless ON OFF Control
                                                                                    
                        
                        
                        
                                                            10DI 10DO Wireless Modbus RTU 10 Digital Inputs 10 Relay Outputs 2km Wireless ON OFF Control
                                                    
                        
                     4 Channels Wireless Modbus RTU 4DI4DO Wireless I O Module Pump / Valve / Tank Level
                                                                                    
                        
                        
                        
                                                            4 Channels Wireless Modbus RTU 4DI4DO Wireless I O Module Pump / Valve / Tank Level
                                                    
                        
                     1W Wireless Pump Controller Remote Pump ON OFF Control 2km Embedded Wireless Solution
                                                                                    
                        
                        
                        
                                                            1W Wireless Pump Controller Remote Pump ON OFF Control 2km Embedded Wireless Solution
                                                    
                        
                     Pump ON-OFF Control System According the Float Switch High Or Low Level
                                                                                    
                        
                        
                        
                                                            Pump ON-OFF Control System According the Float Switch High Or Low Level
                                                    
                        
                     2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
                                                                                    
                        
                        
                        
                                                            2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
                                                    
                        
                     433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF 2km
                                                                                    
                        
                        
                        
                                                            433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF 2km
                                                    
                        
                     16DI 16DO Wireless I O Module PLC Wireless Controller 2km Wireless ON OFF Control
                                                                                    
                        
                        
                        
                                                            16DI 16DO Wireless I O Module PLC Wireless Controller 2km Wireless ON OFF Control
                                                    
                        
                     2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves
                                                                                    
                        
                        
                        
                                                            2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves
                                                    
                        
                     Digital Input Wireless Modbus RTU 2km Wireless Pump Control 868MHz Wireless Lora Module
                                                                                    
                        
                        
                        
                                                            Digital Input Wireless Modbus RTU 2km Wireless Pump Control 868MHz Wireless Lora Module