On-Site Display Isolated Temperature Transmitter Power Energy Industry
|
...Isolated Temperature Transmitter Capable Of Measuring Transmission Under Isolation Protection The on-site display isolated temperature transmitter can achieve measurement, display and transmission under isolation protection. The on-site display isolated temperature transmitter is an instrument integrating four major functions: temperature sensing, electrical isolation......
Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)
|
Industrial Rail Mounted Temperature Transmitters With Galvanic Isolation TMT131A
|
...high level of accuracy. The temperature transmitter is designed to provide high-level isolation between the input and output, which ensures that there is no interference or noise from the input signal. The TMT131A model also has a high level of immunity to...
SENSE Instruments Co., Ltd.
|
2-Wire Programmable Transmitter PR 5331D is loop-powered 2-wire transmitter. Dual-channel input (RTD, TC, mV, mA), galvanic isolation, compact DIN-rail design.
|
...Transmitter PR 5331D Advanced programmable transmitter supporting RTD, TC, Ohm, or mV input with exceptional measurement accuracy and 1.5 kVAC galvanic isolation. Designed for DIN form B sensor head mounting with programmable sensor error detection. Key Features Extremely high measurement accuracy (better than 0.05% of selected range) 1.5 kVAC galvanic isolation......
Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
|
Thermocouple Rtd Head Temperature Transmitter WNK 4-20mA
|
...Temperature Transmitter Product Description Universal Input Isolation Smart Temperature Transmitter WNK65 is suitable for four types of thermal resistors including Cu50, Cu100, PT100, PT1000 and eight types of thermocouple including E, J, B, K, N, R, S, T type. And it supports measurement of minivolt signal of -10~100mV and -100~1000mV, and resistive signal of 0~400Ω and 0~4000Ω. Isolation......
Hefei WNK Smart Technology Co.,Ltd
|
44mm Diameter Hart RTD Liquid Gas Temperature Transmitter
|
... of thermocouple including E, J, B, K, N, R, S, T type. And it supports measurement of minivolt signal of -10~100mV and-100~1000mV, and resistive signal of 0~400Ω and 0~4000Ω. Isolation voltage is...
Hefei WNK Smart Technology Co.,Ltd
|
Endress+Hauser ITEMP TMT72 TMT82 TMT142B TMT162 TMT182B Temperature Transmitter 4-20mA Hart Head Mount Digital Sensor
|
...Temperature Transmitters Professional 4-20mA HART Head Mount Digital Temperature Sensors Technical Specifications Measuring Principle Head Transmitter Auxiliary Power Supply 10...36 V DC Communication PC-Programmable Installation Terminal Head Form B / DIN Rail Accuracy (Pt100, Pt1000, -50...+250°C) ≤ 0.1 K Accuracy (Pt100, Pt1000, -58...+482°F) ≤ 0.18°F Galvanic Isolation......
Xi'an Bairui Electrical Technology Co., Ltd.
|
7NG3212-0AN00 Siemens Temperature Transmitter SITRANS TH300 For Installation
|
...Temperature transmitter SITRANS TH300 For installation About Temperature transmitter 7NG3212-0AN00 Article Number (Market Facing Number) 7NG3212-0AN00 Product Description Temperature transmitter SITRANS TH300 For installation in the connection head, Type B (DIN 43729), Two-wire system 4 ... 20 mA, programmable, communication-capable acc. to HART, with electrical isolation......
Wisdomlong Technology CO.,LTD
|
HART 20mA Infrared Temperature Transmitter 32VDC 44mm Diameter
|
ST04 Temperature Transmitter Features High-voltage isolation: As high as 1000V for the isolation voltage between metal capacitance sensor processing circuit and main circuit. High reliability: Built-in multi-level protection circuit for high reliability. ......
Shaanxi Sier Electronics Co., Ltd.
|
Endress+Hauser TMT162 Temperature Transmitter with Two Universal Sensor Inputs 11,5...42 V DC Power Supply and 0.1 K Accuracy
|
...transmitter Input 2 x RTD, TC, Ohm, mV Output 1 x analog 4...20 mA / HART FOUNDATION Fieldbus H1 PROFIBUS PA Auxiliary power supply 11,5...42 V DC (HART) 11,5...30 V DC (Ex ia) 9...32 V DC (FF, PA) 10,5...24 V DC (Ex ia, FF, PA) Communication HART FOUNDATION Fieldbus PROFIBUS PA Installation in field Accuracy (Pt100) <= 0,1 K (HART, FF, PA) (Pt100) <= 0,18 °F (HART, FF, PA) Galvanic isolation......
Mengchuan Instrument Co,Ltd.
|
ITEMP TMT82 7 Temperature Transmitter TMT82-AAA1CD2TRTRA2
|
... °C) <= 0,1 K (Pt100, -58...392 °F) <= 0,18 °F See all specifications Field of application The iTEMP TMT82 is a highly reliable, accurate and long-term stable temperature transmitter for industrial processes requiring high availability. The versatile 2...
GREAT SYSTEM INDUSTRY CO. LTD
|