| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Battery Pack Tester |
|---|---|
| Accuracy: | ±(0.05%RD+0.05%FS) |
| Model Number: | ACEY-BA100100-12 |
| Number Of Channels: | 12 Channels |
| MOQ: | 1 Set |
| Delivery Time: | 7~35 Days |
| After-sales Service: | 24/7 Technical Support |
| Certification: | CE |
| Packaging Details: | Plywood Case |
| Warranty: | 1 Year Warranty with Lifetime Support |
| Payment Terms: | T/T,PayPal,L/C,Western Union |
| Output Power: | Max. 10KW (Single Channel) |
| Brand Name: | ACEY |
| Current Range: | 0.1~100A (Charge & Discharge) |
| Place of Origin: | China |
| Voltage Range: | 10V-100V |
| Price: | USD 2650~29694/Set |
| Main channel test abort condition: | Time, voltage, current, capacity, etc |
| Supply Ability: | 200 Sets/Month |
| Company Info. |
| Xiamen Acey New Energy Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
100V 100A Charge 100A Discharge Battery Pack Charge Discharge Test Equipment for Energy Storage Systems
Product Description
ACEY-BA100100-12 Energy Feedback Battery Charging and Discharging Testing Machine is designed for battery pack aging, capacity verification, charge-discharge performance evaluation, and temperature characteristic testing. It is suitable for battery pack manufacturing, production quality control, and battery performance assessment for lithium-ion, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium battery packs. The system helps manufacturers evaluate battery capacity, charging and discharging behavior, cycle performance, and operating characteristics under programmable test conditions.
Applicable Battery Types
Lithium-ion battery packs, including ternary lithium and lithium iron phosphate batteries.
Lead-acid battery packs.
Nickel-metal hydride battery packs.
Nickel-cadmium battery packs.
Same-port and separate-port battery packs.
Battery modules with a voltage range of 10V to 100V.
Main Applications
Equipment Features
Programmable Test Steps: Configure charging, discharging, resting, and multi-level cycle sequences according to testing requirements.
Flexible Cutoff Conditions: Set test termination or step switching based on voltage, current, capacity, and time.
Smooth Current Transition: Soft-start output reduces current surges during test startup and CC-to-CV switching.
Detailed Data Recording: Records voltage, current, capacity, energy, temperature, and cycle information for test traceability.
Customizable Curve Analysis: Select and combine test curves to analyze charging and discharging behavior.
Abnormality Detection: Monitors voltage and current variations and can trigger alarms or suspend testing when abnormal conditions occur.
Four-Wire Connection: Separates current and voltage sensing lines for battery testing.
Modular Maintenance Design: Supports convenient power module maintenance and component replacement.
Main Technical Parameter
NO | Item | Function requirement | ||
1 | Channel | 12 | ||
2 | Action Mode | Completely independent | ||
3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC Discharge: constant current discharge CD.& CP Resting, stopping | ||
| Main channel test abort condition | Time, voltage, current, capacity, etc | ||
4 | Voltage of main channel | Votage range of Charge&discharge | 10V-100V | |
Accuracy | ±(0.05%FS+0.05%RD) | |||
Resolution | 1mV | |||
Current of main channel | Maximum output current | 100A | ||
Minimum output current | 100mA | |||
Accuracy | ±(0.05%FS+0.05%RD) | |||
Resolution | 1mA | |||
Power | Output | Single channel continuous operation maximum power 10KW | ||
Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
Cycle times | Max 9999 | |||
Work step time unit | h,min,s are available | |||
Data logging | Min 5S | |||
6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | ||
7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | ||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | ||
10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
12 | Test channel and battery pack connection method | Alligator clamp/OT clamps | ||
13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | ||
10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
12 | Test channel and battery pack connection method | Alligator clamp | ||
13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
Product Display

FAQ 1: What is a battery pack charge and discharge testing machine used for?
The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine is used for battery pack aging tests, charge-discharge cycle testing, capacity measurement, and battery performance evaluation. It supports programmable test procedures for battery manufacturing, module production, and quality control.
FAQ 2: Can a battery tester perform automatic charge and discharge cycle testing?
Yes. The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine supports programmable charging, discharging, resting, and multi-level cycle testing. Users can configure test steps, cycle counts, and termination conditions to meet different battery testing requirements.
FAQ 3: Can a battery charging and discharging tester measure battery capacity and export test data?
Yes. The ACEY-BA100100-12 Battery Charging and Discharging Testing Machine records voltage, current, capacity, energy, and cycle data during testing. Its software supports Excel data export and curve analysis to help users evaluate charge-discharge performance and maintain test records.
|