HX EMT 90-Degree Pull Elbow Access Fittings provide accessible
pulling points at every directional change in conduit raceway
systems. Removable gasketed cover plate with NEMA 4 waterproof
rating. Zinc alloy ZAMAK 3 die-cast. Set-screw EMT connections on
both ends. Complete size range from 1/2 inch to 4 inch. 27 years. UL E345464. ISO9001.
90°Pull Angle
NEMA 4Waterproof
600V+Voltage Rated
9Sizes 1/2-4"
-60%Pull Tension
ConcreteTight Rated
Jobsite Pain Points & HX SolutionsPulling through a standard 90-degree elbow without access creates
friction hot spots. Insulation stretches, thins, and fails
megohmmeter testing. Result: pull out the damaged conductors and
start over. Cost: US$850+ in labor and materials per failed pull.
Removable cover plate provides full access to the interior raceway
at the bend point. Electricians grip conductors directly at the
direction change, reducing pulling tension by up to 60%. Zero
insulation damage. Passes megohmmeter on the first attempt.
Standard pull elbows without gaskets allow moisture infiltration in
parking garages, outdoor equipment pads, and wastewater facilities.
Corrosion inside the raceway damages conductors over time and
creates intermittent ground faults.
Neoprene gasket between body and cover plate achieves NEMA 4
watertight, raintight, and oiltight ratings. Submersion-tested in
production QC. Suitable for wet locations, outdoor installations,
and concrete-embedded applications.
Cheap pull elbows have undersized interior cavities. To meet NEC
Chapter 9 conduit body fill requirements, contractors must oversize
to the next trade size, increasing material cost by 40-60%.
Generously proportioned interior cavity meets NEC conduit body fill
requirements for standard conductor sizes and quantities at the
nominal trade size. No oversizing required. No special engineering
calculations. Code compliant as-specified.
One Fitting, Five Certifications: UL 514B Listed (E345464) | NEMA 4 Watertight | Concrete-Tight
Rated | Raintight | Oiltight
Suitable for applications above 600V. Full documentation package
included with every shipment.
Technical Specifications| Parameter | Specification |
|---|
| Body & Cover | Zinc Alloy ZAMAK 3 High-Pressure Die Casting |
| Cover Seal | Neoprene Gasket, Captive Design |
| Trade Sizes | 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 4 inch |
| Conduit Connection | Set-Screw EMT Slip Fit, Both Ends |
| Cover Fasteners | Combo Head Steel Screws (Slotted / Phillips / Robertson) |
| Angle | 90 Degrees Nominal |
| Environmental Ratings | NEMA 4 Watertight, Raintight, Oiltight, Concrete-Tight |
| Certifications | UL 514B Listed (E345464), ISO9001:2015, SGS |
| Voltage Rating | Suitable for Applications Above 600V |
| Temperature Range | -40 deg C to 120 deg C |
| Conduit Compatibility | EMT Thinwall, IMC, Rigid (Sizes 2-1/2 to 4 inch) |
| MOQ | 2,000 PCS per Size |
| Lead Time | 15-20 Days per 20GP Container |
| Port | Ningbo or Shanghai, China |
Key Features- Full-Access Pulling Chamber — Removable gasketed cover provides complete access at the
90-degree bend. Reduces pulling tension by up to 60%. Eliminates
conductor insulation damage.
- NEMA 4 Multi-Rating — Watertight, raintight, oiltight, and concrete-tight. One fitting
covers indoor, outdoor, and embedded applications.
- NEC-Optimized Cavity Volume — Interior dimensions meet Chapter 9 conduit body fill
requirements at nominal trade size. No oversizing needed.
- Combo Head Cover Screws — Same tri-drive design across the entire HX fitting product line.
One screwdriver handles all installation fasteners.
- UL Listed Above 600V — Suitable for medium-voltage industrial power distribution beyond
standard commercial building voltages.
Installation Scenarios- High-Rise Electrical Risers — Pull floor-by-floor at horizontal-to-vertical transitions
instead of attempting continuous multi-story pulls
- Industrial Overhead Conduit Racks — Provide pulling access where lighting and equipment circuits
navigate around structural steel and HVAC ductwork
- Hospital Critical Branch Circuits — Maintain accessible pulling points for future circuit
modifications in operating room and ICU power distribution
- Data Center Feeder Distribution — Keep pulling tension within manufacturer limits for large-gauge
conductors at cable tray transition points
- Water Treatment Plants — NEMA 4 watertight construction for pump station and outdoor
chemical feed equipment power circuits
- Cast-in-Place Concrete Slabs — Flush-mounted accessible cover remains serviceable after
concrete pour for long-term maintenance access
Packaging & OEMIndividual polybag protection with body and cover packaged
together. Foam cell dividers in master cartons prevent surface
scratching. Project kitting available: pre-labeled cartons
organized by floor, zone, or electrical room per contractor
schedule. OEM private-label options: custom carton printing,
branded inserts, QR-coded installation guides. 12-month defect
warranty. Free replacement for quality non-conformance.