| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Dedicated EDI Module |
|---|---|
| Compatibility: | Integrates with existing ERP and business systems |
| Brand Name: | Aquacells |
| Certification: | FDA,EU,CE,RoHS,REACH |
| Place of Origin: | China |
| Product name: | Dedicated EDI Module |
| Function: | Electronic Data Interchange (EDI) processing and management |
| User interface: | Web-based dashboard with real-time monitoring |
| Error handling: | Automatic error detection and notification |
| Scalability: | Supports small to large enterprise volumes |
| Automation level: | High - supports automated document exchange |
| Support and maintenance: | 24/7 technical support and regular updates |
| Integration capabilities: | API support for custom integrations |
| Model Number: | EIMD-20SP |
| Reporting features: | Comprehensive reporting and analytics |
| Company Info. |
| Aquacells Membrane Technologies Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
The Aquacells EIMD-SP module is tailor-made for the effluent from a single-stage reverse osmosis (RO) system. It demonstrates resilience to fluctuations in water quality and significantly reduces both investment and operating costs.
| Parameter | Specification |
|---|---|
| FCE (including CO2 and Silica) | < 80 µS/cm |
| Feed Water Source | Condensate water |
| Temperature | 5-45 ℃ (40-113 ℉) |
| Feed pressure | 1.4-7 bar (20-100 psi) |
| Total Chlorine (as CI2) | <0.05 ppm |
| Fe | <0.01 ppm |
| Mn | <0.01 ppm |
| S2- | <0.01 ppm |
| pH | 4-11 |
| Total Hardness (as CaCO3) | <1.0 ppm |
| Dissolved Organics (TOC as C) | <0.5 ppm |
| Silica (SiO2) | <1.0 ppm |
| Parameter | Specification |
|---|---|
| Typical Recovery | >85% |
| Maximum Feed Pressure | 7 bar (100 psi) |
| Maximum Feed Temperature | 45 ℃ (113 ℉) |
| Minimum Discharge pressure | > 1 bar |
| DC Voltage* | 0-300 V |
| DC Amperage | 0-6 A |
| Product Resistivity | >10 MΩ·cm |
| Silica (SiO2) Removal | 90-99% depending on feed water |
*Voltage required depends on module size
The information provided in this brochure contains general descriptions or performance characteristics that may not always apply as described in actual use cases or may change due to further product development. An obligation to provide the respective characteristics shall only exist if expressly agreed upon in the terms of the contract.
|