Product Description
Transformer Tester is new product created after widely adopt customers’ advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General
which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced
manufacturing technology ensure a stable and reliable product performance, full-featured, high degree
of automation, high efficiency, in the domestic leading level, they
are the professional testing equipments for transformer check in
power industry.
Product Alias
Comprehensive Instrument Transformer Volt-Ampere Characteristic
Tester / CT Volt-Ampere, Ratio & Polarity Tester / Comprehensive
Instrument Transformer Volt-Ampere Characteristic Tester /
Comprehensive CT Volt-Ampere Characteristic Tester / CT Volt-Ampere
Characteristic Tester / PT Volt-Ampere Characteristic Tester /
Instrument Transformer Volt-Ampere Characteristic Tester /
Comprehensive VA Characteristic / Ratio and Polarity Tester /
Volt-Ampere (VA) Characteristic Tester / Comprehensive Volt-Ampere
Characteristic Tester / Comprehensive CT & PT Characteristic Tester
/ Excitation Characteristic Tester
Features
Full-featured, not only satisfy the test requirements of various
CTs (include TP class), such as the excitation characteristics
(i.e., volt-ampere characteristics), ratio, polarity, secondary
winding resistance, secondary burden, ratio error and phase
displacement, but can also be used for the tests of various PTs,
including excitation characteristics of the electromagnetic unit,
ratio, polarity, secondary winding resistance, ratio error and
phase displacement.
Automatically give CT, VT parameters, including knee point voltage
/ current, 10% error curve, the accuracy limit factor (ALF),
instrument security factor (FS), the second time constant (Ts),
remanence coefficient (Kr), saturated and unsaturated inductance
etc.
Test meet IEC60044-1,IEC60044-2,IEC60044-6
,C57.13,IEC61869-2,IEC61869-3 all kinds of transformer standards,
and in accordance with the transformer types and levels of
automatic choose which standard test.
Based on advanced principle of low-frequency test method that can
meet the CT test on knee voltage up to 30KV.
Friendly interface beautiful, all Chinese graphic interface
The instrument can store 2000 groups of test data that won't be
lost when power off. After test ended, the data can be coped to PC
by USB disk for analysis and being transformed into WORD report.
Test is simple and convenient, one-click can complete tests of CT
secondary resistance, excitation, ratio and olarity.
Easy to carry, because the weight is less than 9Kg.
Product Parameters
**** CT/PT Analyzer |
Usage | Class P/TP CT & VT |
Output | 0~180Vrms,12Arms,36A(peak value) |
Voltage measurement accuracy | ±0.2% |
CT Ratio | Range | 1~40000 |
| accuracy | ±0.2% |
PT Ratio | Range | 1~40000 |
| accuracy | ±0.2% |
Phase | Range | ±5min |
| accuracy | 0.5min |
DC resistance | Range | 0~300Ω |
| accuracy | 2%±2mΩ |
Burden | Range | 0~300VA |
| accuracy | 2%±0.2VA |
Power supply | AC220V±10%,50Hz |
Environmental Conditions | Operating temperature :-10οC~50οC,Humidity :≤90% |
Weight and Dimensions | Dimensions:340mm x220mmx330mm ,Weight<9kg |
Aluminum alloy box dimensions | 430mm x270mm x500mm |
Application Scenarios
FAQ
Q1: What tests can this CT/PT comprehensive tester perform?
It can complete excitation (volt-ampere) characteristic test,
transformation ratio test, polarity check, DC winding resistance
measurement and secondary load test for both current transformers
(CT) and voltage transformers (PT), covering routine power
acceptance inspection items.
Q2: Is external booster equipment needed during testing?
No extra booster or voltage regulator is required. The built-in
variable frequency boost module is integrated inside the host,
which simplifies field wiring and avoids bulky auxiliary devices.
Q3: How to prevent wrong wiring during operation?
Standard CT & PT wiring diagrams are printed clearly on the panel,
with terminals divided by functions and marked with S1, S2, P1, P2,
M1, M2 separately. Color-coded test cables further reduce wiring
errors effectively.
Q4: Why does the test curve appear abnormal or data fluctuate?
Recheck and tighten all test cable clips to remove surface
oxidation; confirm no open circuit or short-circuit fault on the
secondary winding of the transformer; restart the measurement after
troubleshooting.
Q5: Shipping Method
If we place an order, how do you typically ship the goods? Will
there be any issues with transporting bulky items such as reactors?
We default to using dedicated logistics lines or brand-specific
express shipping services; small-sized main units and accessories
may also be shipped via standard courier services. Large items,
such as reactors and excitation transformers, are packed using
wooden crates or wooden frames for reinforcement to prevent bumps
and moisture exposure during transit; a packing list is included
with each package to facilitate item-by-item counting for you.
Logistics costs are typically determined by both parties in
accordance with the contract terms; after shipment, we will send
you both the tracking number and the carrier's contact phone number
for easy tracking.If your project site is remote or if delivery to
the site is required with a specified logistics company, please
inform us in advance when placing your order; we can then
coordinate and arrange accordingly.
Q6: Delivery Lead Time
Our project is under tight deadlines; how long will it take for the
order to be shipped after we place it? Can we request expedited
shipping?
Standard specifications – stock available; typically delivered upon
receipt of the order. Orders can be shipped within [X] working
days; for non-standard products requiring customized voltage
levels, capacities, or reactor combination configurations, the
production cycle typically ranges from [X] to [Y] days.The delivery
time will be approximately 7-15 working days; the specific timeline
shall be subject to the sales confirmation provided upon order
placement. If your project has a tight schedule, please inform us
of the latest expected delivery date before placing your order; we
will first verify the production schedule and inventory status, and
where possible, will coordinate expedited production and prioritize
shipment. However, it is recommended to allocate sufficient transit
time for logistics to avoid delaying on-site testing.
Q7: After-sales Service and Warranty
What is the warranty period for this equipment? If any issues arise
during on-site use, how will your after-sales service respond?
We provide a two-year free warranty on the entire unit and lifelong
technical support services. During the warranty period, if issues
arise due to defects in the equipment itself, we will provide free
repair or replacement of components; when problems occur on-site,
we commit to responding within 24 hours; most wiring and parameter
configuration issues can be resolved through remote guidance via
video or telephone; for cases where an on-site visit is necessary,
we will arrange for our technicians to arrive at the location to
resolve the issue. After the warranty period expires, we still
offer repair services, with spare parts supplied at cost price for
the long term, and software updates provided free of charge for
life. Upon delivery of the equipment, we also offer free
operational training (video operation guides)to ensure that your
testing personnel can operate the equipment independently and
proficiently; should you have any further questions, please feel
free to contact our dedicated after-sales hotline directly.
Q8: Shipping methods for each region (Sea freight)
Our projects are distributed across several states, and our
procurement volumes are substantial; are the shipping methods
consistent across all states? How is the delivery time calculated? The specifications are identical; however, it should be
specifically noted that this equipment set is large in size and
heavy in weight—components such as the reactor and excitation
transformer are all classified as heavy components. Therefore,
regardless of which state or region the shipment is destined for,
we will uniformly utilize sea freight transportation. The packaging
employs export-grade wooden crates with reinforced structures,
along with moisture-proof and rust-proof treatments; the design of
these wooden crates is optimized for long-distance sea transport
and multiple lifting and transshipment operations. Upon arrival at
the destination, simply unpack the goods and conduct an inspection
before putting them into use. Regarding delivery time, the sea
freight transit period depends on the port of destination: near-sea
routes are generally faster, whereas ocean routes may take longer;
the exact number of days will be confirmed based on the shipping
schedule specified in the bill of lading. We have a dedicated
freight forwarding agency to handle booking of shipping space,
customs declaration, insurance, and other related procedures; once
the vessel departs, we will send you documents such as the bill of
lading and the packing list, enabling you to arrange for the
receipt of goods at the port of destination and their inland
transshipment in advance
Shipping scenario
Scene (One)

Scene (Two)

Attachment Directory