| DC Power Supply Voltage | VDD | 3.0 | 3.3 | 3.6 | V | |
| Supply Current | IDD | | 430 | 850 | A | One conversion per second, dynamic averaging disabled |
| Supply Current | IDD | | 930 | 1200 | A | Four conversions per second, dynamic averaging enabled |
| Supply Current | IDD | | 1120 | | A | 16 Conversions per second, dynamic averaging enabled |
| Standby Supply Current | IDD | | 170 | 230 | A | Device in Standby mode, no SMBus communications, ALERT and THERM
pins not asserted |
| Internal Temperature Monitor Temperature Accuracy | | | 0.25 | 1 | C | -5C < TA < 100C |
| Internal Temperature Monitor Temperature Accuracy | | | 2 | | C | -40C < TA < 125C |
| Internal Temperature Monitor Temperature Resolution | | | 0.125 | | C | |
| External Temperature Monitor Temperature Accuracy | | | 0.25 | 1 | C | +20C < TDIODE < +110C |
| External Temperature Monitor Temperature Accuracy | | | 0.5 | 2 | C | -40C < TDIODE < +127C |
| External Temperature Monitor Temperature Resolution | | | 0.125 | | C | |
| Conversion Time (All Channels) | tCONV | | 150 | | ms | Default settings |
| Default Capacitive Filter | CFILTER | | 2.2 | 2.7 | nF | Connected across external diode |
| Output Low Voltage | VOL | 0.4 | | | V | ISINK = 8 mA |
| Leakage Current (ALERT and THERM pins) | ILEAK | | | 5 | A | Device powered or unpowered, TA < 85C, Pull-Up voltage 3.6V |
| SMBus Interface Input High Voltage | VIH | 2.0 | | VDD | V | 5V Tolerant |
| SMBus Interface Input Low Voltage | VIL | -0.3 | | 0.8 | V | 5V Tolerant |
| SMBus Interface Leakage Current | ILEAK | | | 5 | A | Powered or unpowered, TA < 85C |
| SMBus Interface Hysteresis | | | 420 | | mV | |
| SMBus Interface Input Capacitance | CIN | | 5 | | pF | |
| SMBus Interface Output Low Sink Current | IOL | 8.2 | | 15 | mA | SMDATA = 0.4V |
| SMBus Timing Clock Frequency | fSMB | 10 | | 400 | kHz | |
| SMBus Timing Spike Suppression | tSP | | | 50 | ns | |
| SMBus Timing Bus Free Time (Stop to Start) | tBUF | 1.3 | | | s | |
| SMBus Timing Hold Time: Start | tHD:STA | 0.6 | | | s | |
| SMBus Timing Setup Time: Start | tSU:STA | 0.6 | | | s | |
| SMBus Timing Setup Time: Stop | tSU:STO | 0.6 | | | s | |
| SMBus Timing Data Hold Time | tHD:DAT | 0 | | | s | When transmitting to the host |
| SMBus Timing Data Hold Time | tHD:DAT | 0.3 | | | s | When receiving from the host |
| SMBus Timing Data Setup Time | tSU:DAT | 100 | | | ns | |
| SMBus Timing Clock Low Period | tLOW | 1.3 | | | s | |
| SMBus Timing Clock High Period | tHIGH | 0.6 | | | s | |
| SMBus Timing Clock/Data Fall Time | tFALL | | | 300 | ns | Min. = 20 + 0.1CLOAD ns |
| SMBus Timing Clock/Data Rise Time | tRISE | | | 300 | ns | Min. = 20 + 0.1CLOAD ns |
| SMBus Timing Capacitive Load | CLOAD | | | 400 | pF | Per bus line |