| SPD Type: | T2、T3 (IEC 61643.11) |
| Maximum Continuous Operating Voltage (Uc): | 18Vdc / 32Vdc / 60Vdc / 160Vdc / 320Vac |
| Response Time: | ≤25ns |
| Load Current (IL): | 5A (all models) |
| Protection Circuit: | L1-L2、L1-E、L2-E |
| Company Info. |
| Shenzhen LLH Electrical Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
LS-P Series is a T2+T3 level power surge protection device designed for final-level equipment lightning protection in AC and DC power systems, suitable for installation in LPZ 2-3 and subsequent lightning protection zones. As a series-installed fine arrester at the front end of equipment, it provides targeted protection for sensitive electronics and precision devices.
Featuring two ports and full-mode protection, the product offers
comprehensive shielding against surges in line-line and line-earth
paths. The compact size (90mmx36mmx68mm) and 35mm DIN Rail mounting
make it suitable for space-constrained environments such as
equipment cabinets and control panels. The PA66 housing (V0
flame-retardant grade) offers excellent fire resistance and
durability.
| Product Features |
● Two ports, full mode protection |
● Small size and easy installation |
● Suitable for installation in LPZ 2-3 and subsequent lightning
protection zones, used for lightning protection of final level
equipment in AC and DC power systems, and a fine lightning arrester
installed in series at the front level of the equipment. |
Product Specification
Standards | IEC 61643-11 | ||||
SPD type | T2,T3 | ||||
Models | LS-P12 | LS-P24 | LS-P48 | LS-P110 | LS-P220 |
Electrical parameters | |||||
Nominal operating voltage Un | 12Vdc | 24Vdc | 482Vdc | 110Vdc | 220Vdc |
Maximum continuous operating voltage Uc | 18Vdc | 32Vdc | 60Vdc | 160Vdc | 320Vac |
Nominal discharge current (8/20μs)In | 2kA | 5kA | |||
Maximum discharge current (8/20μs) Imax | 3kA | 10kA | |||
Voltage protection level In@Up | ≤150V | ≤200V | ≤300V | ≤500V | ≤1.25kV |
Response time tA | ≤25ns | ||||
Load current IL | 5A | ||||
failure mode | open circuit | ||||
Deterioration indication | LED green: OK; Off: Fail | ||||
Protection Circuit | L1-L2,L1-E,L2-E | ||||
Installation method | DIN Rail 35mm |
Screw torque | 1N*m |
Strip length | 10mm |
Wiring cross-sectional area | 0.75mm²-2.5mm² |
Product size | 90mmx36mmx68mm |
Shell material and flame retardant grade | PA66,VO |
Installation position | Indoor |
Degrees of protection provided by enclosure | IP20 |
Temperature range | -40℃…+80℃ |
Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
●This product is a final-level protector, should be installed as close as possible to the protected equipment (distance ≤5m).
●Use wiring with cross-sectional area 0.75mm²-2.5mm² and tighten screws to 1N·m torque.
●Ensure reliable grounding with ground resistance ≤4Ω to guarantee protection effect.
●Do not exceed the maximum load current (5A) to avoid overheating or equipment damage.
●Replace the SPD immediately if the LED indicator is off (failure status) or after severe surge impact.
●Select the appropriate model based on the power system type (DC/AC) and voltage.
FAQ
Q1: What is the load current capacity of LS-P Series?
A1: The maximum load current is 5A, suitable for low-power sensitive equipment and electronics.
Q2: Can LS-P220 be used for DC 220V systems?
A2: No, LS-P220 is specifically designed for AC 220Vac systems. For DC 220V applications, consult technical support for dedicated models.
Q3: What is the failure mode of this SPD?
A3: It adopts open-circuit failure mode, which automatically disconnects from the circuit when faulty to avoid short circuits or other hazards.
Q4: Is the product compatible with smart home systems?
A4: Yes, its compact size and low leakage current make it suitable for integration into smart home control systems.
Q5: How to test if the SPD is working normally?
A5: Use a surge generator to simulate transient overvoltage; if the SPD diverts the surge current and limits the voltage to the specified level, it is working normally. Regular visual inspection of the product (no physical damage) is also recommended.
|