| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | MBR Membrane |
|---|---|
| Brand Name: | SINOMEMB |
| Model Number: | SNU-HO-2-Z160L |
| Certification: | NSF |
| Place of Origin: | China |
| MOQ: | 5 |
| Packaging Details: | Standard export packaging |
| Core Components: | MBR |
| Product name: | hollow fiber ultrafiltration membrane, ultrafiltration system, PVC Hollow fiber UF membrane module |
| Pore size: | customized., from 1μm to 0.05μm, 0.01micron, 1.0μm, 0.2μm |
| Module: | Out-inside |
| Size: | 160×1810mm |
| Membrane Material: | PVDF |
| Surface Area: | 10-100 m2 |
| Product Type: | Skincare |
| Operating Temperature: | 5-40 Degrees Celsius |
| Availability: | Online and in select stores |
| Flow Rate: | 10-20L/m2.h |
| Target Concerns: | Aging, Dryness, Dullness |
| Filtering Type: | Flat Sheet Membrane |
| Benefits: | Hydrating, Anti-aging, Brightening |
| Productivity: | 330~4800L/Hour |
| Company Info. |
| Sinomemb Environment Technology (beijing) Co., |
| Verified Supplier |
| View Contact Details |
| Product List |


Operation Guide
During the operation of the UF system, it is necessary to avoid
sudden changes in pressure during system start-up, shutdown,
operation, cleaning, maintenance, etc., as well as exceeding the
maximum withstand pressure specified in this manual, to prevent
possible membrane breakage, sealing, etc. End fall off, membrane
shell cracking and other serious damage consequences; this series
of products have been treated with anti-corrosion and membrane wire
protection before leaving the factory, and the inner membrane wire
of the module is in a semi-dry state. For manual operation, the
water production rate should be set to 50% of the design water
production rate, and the initial water production must be
discharged directly and cannot be used as product water.
The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.
Failure to operate in strict accordance with the operating limits
and guidelines set forth herein voids our limited warranty. If the
UF system is out of service, please inject protective liquid inside
the membrane module for anti-corrosion treatment, so as to avoid
the increase of maintenance cost caused by the large number of
microorganisms in the system.
Partial OEM model parameters of SINOMEMB ® UF membrane
| UF specifications and models | Membrane material | Operation mode | Membrane element size (mm) | Effective membrane area (㎡) | Nominal filter pore size (μm) |
| SN U-HO-2-Z250 | PVDF | outside-in | Φ250×1715 | 75 | 0.03 |
| SNU-HO-2-Z225L | PVDF | outside-in | Φ225×1760 | 60 | 0.03 |
| SNU-HO-2-Z160L | PVDF | outside-in | Φ160×1810 | 40 | 0.03 |
Note: The element model (membrane performance, appearance size) not