| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Coal Steam Boiler |
|---|---|
| Brand Name: | Gentle boiler |
| Model Number: | DZL6-1.0-T |
| Certification: | ISO |
| Place of Origin: | China |
| MOQ: | 1set |
| Price: | USD25000/Set |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 100sets per month |
| Delivery Time: | 15working days |
| Packaging Details: | Regular Packing or Nude Packing, suited to land transportation as well as sea transportation. |
| Type: | Natural Circulation |
| Structure: | Chain Grate Stoker |
| Pressure: | 0.7Mpa-3.8Mpa |
| Style: | Horizontal |
| Output: | Steam |
| Thermal efficiency:: | 92.4%--94.5% |
| steam temperature: | 184°C, 194°C,204°C,225°C |
| Fuel: | Coal or Biomass |
| Capacity: | 6ton, 6000kg/h |
| Material: | Q235B Carbon Steel |
| Tube: | Water tube and fire tube |
| Company Info. |
| Henan Jinzhen Boiler Company |
| View Contact Details |
| Product List |
Introduction
DZL series package boilers are horizontal three-pass water & fire tube boilers with a chain grate stoker structure. Threaded pyrotechnic tubes are arranged in the drum to form a convection heating surface, while the drum and the water walls on both sides form a radiation heating surface in the furnace. Each package system is fully installed and wired before being transported to site and is electrically controlled to provide functions such as stepless speed regulation for the stoker, threshold parameter alert and interlock protection.
Technical Parameters
| Model | Rated evaporation capacity (t/h) | Working pressure (Mpa) | Rated steam temperature (°C) | Feed water temperature (°C) | Boiler body heating area (m2) | water pressure testing pressure (M pa ) | Effective area of grate (m2) | Thermal efficiency (%) |
| DZL0.5-0.7-T | 0.5 | 0.7 | 170.4 | 20 | 17.5 | 1.05 | 1.1 | 82 |
| DZL1.0-0.7-T | 1 | 0.7 | 170.4 | 20 | 28.6 | 1.05 | 2.14 | 82 |
| DZL1-1.0-T | 1 | 1 | 184 | 20 | 28.6 | 1.4 | 2.14 | 82 |
| DZL1-1.25-T | 1 | 1.25 | 193.3 | 20 | 28.6 | 1.65 | 2.14 | 82 |
| DZL2-0.7-T | 2 | 0.7 | 170.4 | 20 | 55.1 | 1.05 | 2.64 | 82 |
| DZL2-1.0-T | 2 | 1 | 184 | 20 | 55.1 | 1.4 | 3.41 | 82 |
| DZL2-1.25-T | 2 | 1.25 | 193.3 | 20 | 55.1 | 1.65 | 3.41 | 82 |
| DZL4-1.25-T | 4 | 1.25 | 193.3 | 20 | 91.5 | 1.65 | 6.12 | 82 |
| DZL4-1.6-T | 4 | 1.6 | 204.3 | 20 | 91.5 | 2 | 6.12 | 82 |
| DZL4-2.5-T | 4 | 2.5 | 226 | 20 | 91.5 | 3.125 | 6.12 | 82 |
| DZL6-1.25-T | 6 | 1.25 | 193.3 | 20 | 146 | 1.65 | 6.73 | 82 |
| DZL6-1.6-T | 6 | 1.6 | 204.3 | 20 | 146 | 2 | 6.73 | 82 |
| DZL10-1.25-T | 10 | 1.25 | 193.3 | 104 | 288.2 | 1.65 | 12.4 | 82 |
| DZL15-1.25-T | 15 | 1.25 | 193.3 | 104 | 432.3 | 1.65 | 16.2 | 82 |
| DZL20-1.25-T | 20 | 1.25 | 193.3 | 104 | 576.4 | 1.65 | 24 | 82 |
Performance characteristics
1. Designed with horizontal, three passes, all-wet back structure.
2. Fire tubes are surrounded by water, and these design making
efficient up to 80%
3.Threaded tube: Strengthen the heat transfer, increase the boiler
heat efficiency
4. Big combustion room design: increase furnace heating area,
decrease boiler size, and reduce the emission of the Nox Corrugated
hearth make the boiler safer.
5.Adopting water seal eliminate slag, slag through grate drop into slag notch.


Advantage
1 The boiler barrel is consisted of arched tube plate and thread smoke tube, it makes the boiler Quasi steel body into quasi-elastic body structure. It cancel brace part of the tube plate, reduce the stress .Tube plate's smoke tube change from double return into single return. It solves problem of the tube plate crack
2 It takes the thread smoke tube to enhance heat transfer, improve the heat transfer coefficient and thermal efficiency. Due to disturbance of smoke in the tube, the smoke pipe is not easy to accumulate dust ,it can clean by itself .
3 The bottom of the boiler barrel layout with bank of tubes. It will avoid the dead water region in the bottom of the boiler barrel, then sludge is hard to deposit. Boiler barrel can get good cooling, it avoid the bottom of the pot shell burnt or bulge effectively.
4 Stable operation, convenient adjustment, supply strong power.
5 The boiler can remove the dust automatically, to ensure the smoke
dust to reach the ruled norm of the environment protection

FAQ
1.What are the spare parts for DZL/SZL series coal/biomass fired boiler?
Generally, the spare parts are instrumentation valve, grate plate, gasket, etc.
2.What are the differences between vertical type boiler and
horizontal type boiler with the same capacity?
1.Structure of vertical boiler is compact, occupy a limited area,
2.Convenient on installation and removal.
3.Low cost and investment on capital construction. Steam exhausted
fast and sufficient.
1.The combustion space of horizontal is big, fuel can be burned
completed.
2.The thermal efficiency is higher than the vertical boiler,
3.Horizontal type: less thermal loss, stronger output, and higher
steam quality.
3.What are the limitation (size, humidity, chemical element
concentrations) of coal fuel/solid fuel/wood fuel?
Size requirement of coal:6-25mm
Size requirement of blending coal: <50mm (the coal less than 6mm
should less than 30%)
Diameter of biomass particle: 6~10mm, length: 25~50mm, water
content < 15%, ash content < 2%, sulphur content<0.07%,
chlorinity <0.07%, nitrogen content < 0.5%
4.What is the size of furnace door and blower hopper?
Size of furnace door:
Standard elliptical furnace door:300*800*1500
Blower hopper size:
2 tons conical hopper: 1400*800*1500
4 tons conical hopper: 2200*1400*1500
|