Sign In | Join Free | My chinacomputerparts.com
chinacomputerparts.com
Products
Search by Category
Home > Air Conditioners >

Black Cap Vacuum Blood Collection Tube High-Throughput(ESR) Integrated ESR/Hematocrit

Categories Vacuum Blood Test Tube
Brand Name: Orsin
Model Number: Gel Clot ActivatoR
Certification: ISO 13485
Place of Origin: China
MOQ: 100/pcs
Price: Negotiation
Payment Terms: L/C,D/A,D/P,T/T,Western Union
Supply Ability: 20million/pcs/moth
Delivery Time: 1-4 weeks
Application Scenarios: Room-Temperature Storage
Automatic Piping: YES
Anticoagulant System: Composite Antimony System Technology
Labeling: Pre-printed with barcode
Behavior: Strong temperature tolerance
Productivity: 12000pcs/hour
Anticoagulant Properties: Excellent
Storage: Store at room temperature
Key Advantages: Wide Compatibility
Inner Wall Treatment: Bionic active membrane
Closure Type: Rubber Stopper
Logo Printing: Available for big orders (>30000 PCS)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Black Cap Vacuum Blood Collection Tube High-Throughput(ESR) Integrated ESR/Hematocrit

ESR Blood Collection Tubes: Professional Solution for Clinical Erythrocyte Sedimentation Rate Testing

1 Application Scenarios: Precision Monitoring of Inflammation and Disease Activity

ESR (Erythrocyte Sedimentation Rate) blood collection tubes are critical tools in clinical laboratories for assessing systemic inflammation. These specialized vacuum tubes serve essential functions across multiple medical contexts:

  • Diagnosis and Monitoring of Inflammatory Diseases: ESR testing is fundamental for tracking autoimmune disorders like rheumatoid arthritis and systemic lupus erythematosus. Standardized ESR tubes enable accurate assessment of disease progression and treatment efficacy.

  • Infectious Disease Evaluation: ESR values rise significantly during acute bacterial infections (e.g., tuberculosis). Standardized samples ensure reliable infection severity assessment, particularly valuable in pediatric fever investigations.

  • Multiple Myeloma Screening: As a key screening indicator for plasma cell malignancies, ESR testing requires specialized tubes to prevent false negatives caused by imprecise anticoagulant concentrations.

  • Health Check-ups and Chronic Disease Management: ESR serves as a sensitive marker for subclinical inflammation in routine examinations. Dedicated tubes enhance result accuracy and support cardiovascular risk prediction.

  • Research Applications: In clinical trials and disease mechanism studies, standardized samples ensure cross-study data comparability and result reliability.

ESR tubes minimize operational errors through standardized anticoagulant ratios and vacuum design, ensuring erythrocyte sedimentation reflects true pathological states. Compared to regular tubes, specialized ESR tubes achieve >95% correlation with the reference Westergren method.

2 Product Highlights: Technological Innovation Ensures Accuracy

ESR tubes incorporate advanced engineering to deliver superior clinical performance:

Feature CategoryTechnical SpecificationClinical Value
Contamination PreventionClosed vacuum system; direct blood transfer to anticoagulant tubeEliminates operator exposure; reduces lab contamination; complies with biosafety standards
Operational EfficiencyDistinctive black cap; pre-measured anticoagulant; ready-to-useStreamlines workflow; reduces sampling errors
Result Precision0.129mol/ L(anticoagulant:blood=1:4); concentration-controlledEnsures consistent anticoagulation; prevents ESR deviations
System CompatibilityCompatible with major automated ESR analyzers (e.g., ESR-30/40); LIS/HIS integrationEnhances lab efficiency; reduces transcription errors
Interference ResistanceSpecialized anticoagulant minimizes effects of icteric/hemolyzed/lipemic samplesExpands detectable sample range; improves reliability in pathological states

3 Usage Precautions: Standardized Operations Ensure Reliability

3.1 Pre-collection Preparation

  • Tube Selection: Verify black-capped ESR-specific tubes contain 3.8% sodium citrate. Inspect for particulates, sedimentation, or cap looseness.

  • Storage Conditions: Store at 4-25°C. Avoid freezing (causes tube fracture) or high temperatures (degrades anticoagulant).

  • Patient Preparation: Collect blood from calm, preferably fasting patients. Note non-fasting status on requisition forms.

3.2 Blood Collection Protocol

  • Order of Draw: Follow international sequence: blood culture → coagulation tubes → other anticoagulant tubes → ESR tubes (black cap). Prevents anticoagulant cross-contamination.

  • Exact Fill Volume: Draw precisely to fill line (typically 2mL). Underfilling causes false-low ESR; overfilling promotes microclot formation.

  • Mixing Technique: Gently invert 5-10 times immediately after collection. Avoid vigorous shaking to prevent partial anticoagulation or hemolysis.

3.3 Post-collection Handling

  • Testing Timeline: Analyze within 2 hours. Delayed testing alters erythrocyte morphology. Store at 18-25°C if necessary (NEVER refrigerate).

  • Tube Orientation: Transport upright to avoid disturbing sedimentation.

  • Sample Rejection Criteria: Reject clotted, severely hemolyzed, improperly filled (>±10%), unlabeled, or damaged specimens.

*Note: 30% of ESR errors originate from pre-analytical issues, primarily inaccurate fill volumes and improper mixing.*

4 Troubleshooting: Solutions for Operational Challenges

IssueRoot CauseResolution
HemolysisHigh initial flow rate; excessive mixing forceAngle tube during draw; gentle inversions; recollect if hemolyzed
LeakageLoose needle sheath; punctured sheathInspect sheath pre-use; replace device; contain leaks with alcohol swabs
Insufficient FlowNeedle against vein wall; low vacuum; poor venous pressureAdjust needle; replace tube; verify venous access; restore vacuum (sterile)
UnderfillingLow vacuum; premature withdrawal; hypovolemiaUse syringe method (<10% deficiency); recollect if >10% deficient
Needle DislodgementMechanical tension during multi-tube draws; patient movementSecure needle hub; change tubes gently; re-puncture at new site if dislodged

Critical Insight: Hemolysis accelerates ESR by altering plasma viscosity. Prevent by angling tubes 30-45° during initial blood flow.

5 Technical Specifications: Standard-Compliant Parameters

ParameterStandard RequirementTechnical Notes
Anticoagulant3.8% sodium citrate (109mmol/L)ICSH/CLSI recommended; chelates calcium to block coagulation
Fill Volume1.6mL±0.1mL (anticoagulant 0.4mL)Strict 1:4 anticoagulant:blood ratio; black-ring marked
Vacuum Accuracy≤±10%Optimal fill time: 45-60 seconds; use high-altitude tubes >3000m
Mixing5-10 gentle 180° inversionsAvoid agitation; incomplete mixing causes microclots
Sample TypeVenous whole bloodAvoid capillary blood; draw from non-IV arm
Shelf Life18-24 months (room temp, dark)Post-expiry vacuum loss; anticoagulant decomposition
Tube CoatingHydrophobic ultra-smooth surfaceMinimizes cell adhesion; some feature anti-fog agents
Instrument CompatibilityWestergren racks; ESR-30/40; SD-1000; BK-ESR20Dimensions: Ø13mm × ≥200mm length (Westergren equivalent)

Key Specifications:

  • Dimensions: ≥200mm length (215mm in some models); 2.4-2.55mm inner diameter (correlates 0.967 with Westergren)

  • Anticoagulant Technology: Spray-dried film ensures instant mixing; concentration validated to prevent ESR suppression/exaggeration

  • Automation Compatibility: Direct loading into analyzers with temperature compensation (e.g., ESR-2040); throughput: 40-80 samples/hour

  • Innovations: Barcoding for traceability; anti-fog coatings maintain optical clarity

6 Conclusion: Enhancing Laboratory Quality Assurance

ESR tubes exemplify modern laboratory medicine's emphasis on pre-analytical quality control. Their standardized design resolves historical limitations of manual ESR testing. Proper utilization across storage, collection, and testing phases is imperative for accurate clinical decision-making.

Future advancements include integrated ESR/hematocrit testing and point-of-care miniaturized tubes for decentralized settings. As epitomized in laboratory medicine: "Test quality begins at the collection tube and culminates in clinical decisions."

China Black Cap Vacuum Blood Collection Tube High-Throughput(ESR) Integrated ESR/Hematocrit factory
Send your message to this supplier
 
*From:
*To: Shanghai Orsin Medical Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 