Sign In | Join Free | My chinacomputerparts.com
chinacomputerparts.com
Products
Search by Category
Home > Other Measuring & Analysing Instruments >

Insulation Oil Dielectric Loss And Resistance Tester SH115B High Frequency Heating

Categories Freezing Point Tester
Brand Name: Shandong Shengtai Instrument Co., Ltd.
Model Number: SH115B
Certification: GB/T5654
Place of Origin: CHINA
MOQ: 1
Payment Terms: T/T
Supply Ability: 10000 sets/year
Delivery Time: 7-15 work days
Packaging Details: wooden case
Capacitance measurement range: 5pF~200pF
Measurement range of dielectric loss: 0.00001~100
Range of resistivity measurement: 2.5MΩm~20TΩm
Dimensions: 420 * 380 * 385mm
Power: 100 W
Weight: 21Kg (excluding oil cup)
Environmental temperature: 0-40 ℃
Environmental humidity: <80% RH
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Insulation Oil Dielectric Loss And Resistance Tester SH115B High Frequency Heating

SH115B Insulation Oil Dielectric Loss and Resistance Tester

SH115B insulation oil dielectric loss and resistivity tester is an integrated high-precision instrument used for testing the dielectric loss angle and volume resistivity of liquid insulation media such as insulation oil. Internally integrated with main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss testing bridge, AC test power supply, standard capacitor, high resistance meter, DC high voltage source, etc. The heating part adopts the currently advanced high-frequency induction heating method, which has the advantages of non-contact between the oil cup and the heating element, uniform heating, fast speed, and convenient control. The AC test power supply adopts AC-DC-AC conversion method, effectively avoiding the influence of mains voltage and frequency fluctuations on the accuracy of dielectric loss testing. Even if the generator generates electricity, the instrument can operate correctly. The internal standard capacitor is an SF6 gas filled three pole capacitor, whose dielectric loss and capacitance are not affected by environmental temperature, humidity, etc., ensuring consistent accuracy even after long-term use of the instrument. The measurement of resistivity complies with GB/T5654.

The instrument adopts fully digital technology internally, with intelligent automated measurement and multiple measurement modes. It is equipped with a large screen (320 × 240) touch sensitive display, a fully Chinese menu, and Chinese prompts for each step. The test results can be printed and output, and operators can proficiently use them without professional training.

Main technical indicators and parameters of the equipment

ParameterIndex
Capacitance measurement range5pF~200pF
Capacitive resolution0.01pF
Measurement range of dielectric loss0.00001~100
Dielectric loss resolution10-5
Range of resistivity measurement2.5MΩm~20TΩm
Resistivity resolution0.001M
Capacitance measurement accuracy0.5%+1PF
Dielectric loss measurement accuracy± (1% reading+0.0001)
Measurement accuracy of resistivity± 10% reading
Temperature control accuracy± 0.5 ℃
Temperature control range0-125 ℃
AC voltageAC 0-2000V
DC voltageDC 0-500V
Environmental temperature0-40 ℃
Environmental humidity<80% RH
Working power supplyAC220V ± 10% (50 ± 1) Hz
Dimensions420 * 380 * 385mm
Power100 W
Weight21Kg (excluding oil cup)

Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice.

Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:

----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;

----The materials and main components provided meet the technical requirements specified in the technical documentation;

----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).

----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.

----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.

----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.


Packing list

NumberNameQuantityUniotNote
1Instrument host1Unit
2Oil cup1Piece
3Test temperature sensing line1Root
4Data acquisition line1Root
5Check the 2KV high-voltage test line1Root
6Send testing line1RootBlack/Long/One end clip/One end connector
7Measuring cup1Piece50ml
8Power line1Root
9Instructions1Copy
10Packing list1Copy
11Certificate of Conformity Warranty Card1Copy

China Insulation Oil Dielectric Loss And Resistance Tester SH115B High Frequency Heating factory
Send your message to this supplier
 
*From:
*To: Shandong Shengtai instrument co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0