| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Flammability Test Equipment |
|---|---|
| Brand Name: | Gold |
| Model Number: | GD-ISO9185 |
| Certification: | ISO |
| Place of Origin: | CHINA |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 1 Set per 30 days |
| Delivery Time: | 30days |
| Packaging Details: | Standard Wooden Case |
| Name: | Needle flame test machine |
| Standard: | IEC 60695 |
| Dimension: | L1120 * W520 * H1250mm, |
| Burner flame angle: | 0- 45 ° (arbitrary adjustment) |
| The combustion gases: | 95% butane gas or propane gas |
| Temperature range: | 0--1000 ℃ |
| Temperature sensor: | K-type insulation-sheathed thermocouple (Φ0.5mm |
| The flame height: | 12mm ± 1mm; |
| Company Info. |
| Chongqing gold mechnical and electrical equipment Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC 60695 Needle flame test machine
Production introduction:
The IEC 60695 series sets global benchmarks for evaluating fire hazards in electrical and electronic products. Key tests include the Glow-Wire Test (IEC 60695-2-10/11) to assess ignition resistance under overheating, Flame Tests (50W/500W and Needle Flame) for material flammability, and Horizontal/Vertical Burning Tests (IEC 60695-11-10) to classify flame-retardant ratings (e.g., V-0, HB). These standards ensure compliance with certifications like UL and CE, covering components from plastics to circuit boards. Critical for manufacturers targeting international markets, IEC 60695 validates safety against real-world fire risks, supporting design integrity and regulatory approval.

Standard :
1. Glow-Wire Test
- Standard number: IEC 60695-2-10 / IEC 60695-2-11
- Test purpose: To evaluate the ignition and flame retardancy of
materials or components under high temperature conditions, and to
simulate the local overheating scenario caused by circuit failure.
- Method:
- Use a nickel-chromium wire heated to a specific temperature (such
as 550°C–960°C) to contact the sample surface and observe whether
combustion or continuous flame occurs.
- The results are evaluated by "ignition temperature" (GWFI) and
"flammability temperature" (GWIT).
- Application: Electronic and electrical equipment housing,
insulating materials, etc.
- Similar standards: VDE 0471-2-1, GB/T 5169.10-2017.
---
2. Flame test series
(1) 50W flame test
- Standard number: IEC 60695-11-4
- Test purpose: To evaluate the flame retardant performance of
small electrical equipment or materials under low-intensity flame
(50W).
- Method:
- Use a specific burner to apply a 50W flame to observe whether the
sample ignites, the flame spreads, and whether the dripping
material ignites the absorbent cotton.
- Application: Household appliances, connectors, small plastic
parts, etc.
- Similar standards: UL 94 HB, EN 60695-11-4.
(2) 500W flame test
- Standard number: IEC 60695-11-20
- Test purpose: To simulate the burning effect of a high-intensity
fire source (500W) on the equipment casing or material, and verify
the fire isolation performance.
- Method:
- The flame continuously acts on the sample surface, and the
burning time, smoke generation and flame penetration are recorded.
- Application: Fire assessment of industrial equipment, power
cabinets, and building materials.
- Similar standards: ISO 9772 (foam plastic combustion test).
(3) Needle Flame Test
- Standard number: IEC 60695-11-5
- Test purpose: To simulate the risk of local combustion caused by
fault arc or small flame.
- Method:
- Use a 12mm high flame (from a butane burner) to contact the
sample to evaluate the flame spread and self-extinguishing ability.
- Application: Electronic components, PCB boards, insulation
materials, etc.
- Similar standards: ISO 1210, BS 415-20.2.
---
3. Horizontal and vertical combustion test
- Standard number: IEC 60695-11-10
- Test purpose: To evaluate the burning rate and self-extinguishing
property of the material, and to classify the flame retardant level
(such as V-0/V-1/V-2).
- Method:
- Horizontal combustion (HB grade): The sample is placed
horizontally and the linear burning rate is measured.
- Vertical combustion (V grade): The sample is placed vertically
and the afterflame time and whether the dripping material ignites
the absorbent cotton are recorded.
- Application: Plastics, foams, electronic and electrical
components (such as switches and sockets).
- Similar standards: UL 94, ISO 1210.
---
4. Guide to Fire Hazard Assessment
- Standard number: IEC 60695-1-30
- Content: Provides a pre-selected test process for fire risk
assessment of electrical products, including test environment
settings, equipment inspections, safety specifications and data
recording requirements.
- Application: Guide manufacturers to incorporate fire safety
considerations from the design stage and support international
certification (such as CE, UL).
Technical Parameters:
1. Needle burner is made of stainless steel:the hole dia. 0.5mm ± 0.1mm, diameter≤0.9mm, length≥35mm
2. Burner flame angle:0- 45 ° (arbitrary adjustment)
3. The combustion gases: 95% butane gas or propane gas;
4.Subplate: white pine plank ( 10mm),
Surface covered by standard silk paper
200mm ± 5mm below the flame
5. Temperature range: 0--1000 ºC
6. The flame temperature requirements: 100 ± 2 ºC ~ 700 ºC ± 3 ºC,
Heating rise time: 23.5 ± 1.0s;
7. The flame height: 12mm ± 1mm;
8. Ignition time: 0s ~ 999.9s adjustable, generally 30s;
9. Burning time: 0s ~ 999.9s, automatic recording, manual pause;
10. Test Space: ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements);
11. Temperature sensor: K-type insulation-sheathed thermocouple (Φ0.5mm)
12. Automatic test program , independent exhausting system;
13. Dimension: L1120 * W520 * H1250mm,
Packing list:
| Device name | Needle flame tester | ||
| NO. | Name | Quantity | Packing method |
| 1 | Sample fixture | 1 | With equipment |
| 2 | Layer board | 1 | With equipment |
| 3 | Flame scale | 1 | With equipment |
| 4 | Certificate of conformity | 1 | With equipment |
| 5 | Product instruction manual | 1 | With equipment |
| 6 | Power cord | 1 | With equipment |
| 7 | Manual igniter | 1 | With equipment |
| 8 | Clamp | Several | With equipment |
| 9 | Plug gauge | 1 | With equipment |
| 10 | Thermocouple | 1 | With equipment |
| 11 | Replacement needle | 1 | With equipment |
|