| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Cold Room Air Cooler |
|---|---|
| Brand Name: | Kaideli |
| Model Number: | GUDL,GUDD,GUDJ |
| Certification: | CE,ISO9001-2008 |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | 1 |
| Payment Terms: | TT,LC,Western Union |
| Supply Ability: | 1 |
| Delivery Time: | 10-15 days |
| Packaging Details: | Wood box packing |
| Applicable Industries: | Restaurants, merchants |
| Showroom Location: | Viet Nam, Philippines, Mexico, Thailand, Kazakhstan, Nigeria, Uzbekistan, Tajikistan |
| Video outgoing-inspection: | YES |
| Machinery Test Report: | YES |
| Type: | Evaporator |
| Application: | Refrigeration Parts |
| Warranty: | 1 |
| Refrigerant: | R134a/404A、AR507A |
| Material: | copper |
| Cooling capacity: | 0.94-21.5kw |
| High temperatre: | 4.5mm |
| Medium temperature: | 6.0mm |
| Low temperature: | 9mm |
| Voltage: | 220/380 |
| Brand: | Kaideli |
| Test: | 2.6Mpa |
| Fan: | Axial |
| After Warranty Service: | Online support |
| Local Service Location: | None |
| Marketing Type: | New Product 2024 |
| After-sales Service Provided: | Online support |
| Port: | Ningbo/Shanghai/Guangzhou |
| Conditon: | New |
| Color: | Option (White,green,black) |
| Company Info. |
| ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
NAME:G Series High-Efficiency Evaporator Air Cooler | New Energy-Saving Design for Cold Room & Commercial Refrigeration Systems
1. Structural Design
▸ Corrosion-Resistant Casing
Base model: 1.2mm SGCC steel with cryogenic powder coating (-40℃~120℃ operational)
Upgrade options: 5052-H32 aluminum alloy / 304 stainless steel (IP65 certification available)
2.0mm aluminum alloy tube sheets prevent thermal expansion leakage (ΔL/L₀ ≤0.12%)
2. Dual-Layer Condensate Management
✓ Outer Pan: Hinged access panel with 15° ribbed drainage slope (EN
16713 compliant)
✓ Inner Pan: Seamless aluminum construction reduces air bypass
(<3%)
✓ Ice Prevention: Integrated heating cables (3.5W/cm²) with PT1000
thermal sensors
3. Enhanced Thermal Exchange System
• Coil Design: Φ9.52mm micro-grooved copper tubes (HCFC-free
compatible)
• Fin Configuration: Sinusoidal aluminum fins (FPI=16) with
hydrophilic coating
• Airflow Pattern: Δ-arranged tube matrix enhances NTU by 22% vs
conventional designs
4. Performance-Oriented Components
EC Motor Fans: IP55-rated, Class F insulation (25,000h MTBF)
▶ Speed range: 800-1800 RPM (PWM controlled)
▶ Operating envelope: -40℃~60℃ ambient temperature
Defrost System: 316L stainless heating elements with PID control
▶ Surface load: ≤1.8W/cm² (UL 1995 compliant)
▶ 4-zone thermal distribution (σ≤0.85)
5. Engineering Certifications
✓ Pressure tested at 25bar (362.5psi) per ASME BPVC Section VIII
✓ Refrigerant compatibility: R404A/R507A/R134a/R22 (ASHRAE 34
compliant)
✓ Fin spacing options: 4.5/6.0/9.0mm (EN 327/328 certified)
6. Customization & Quality Control
◈ Electrical housing: NEMA 4X junction box with Phoenix terminals
◈ Production validation: 100% helium leak test + 24hr load
simulation
◈ OEM services: CFD-optimized airflow designs available
Technical Advantages Highlight
① 35% Energy Saving - Optimized airside ΔT through enhanced turbulence
② Zero Ice Accumulation - Smart defrost cycle (Patent pending: CN202310XXXXXX)
③ 20-Year Service Life - Salt spray test >1000hrs (ISO 9227 NSS standard)
2. Technical Parameters List
Technical parameters of efficient air cooler of electric defrosting
ceiling Spacing: 4.5mm
| Model | Refrigerating capacity kW | Tube volume | Fan parameters | Defrosting (electric heating) | |||||
| SC1 | SC2 | dm3 | 风叶数量X直径 Number X diameter of fans | 功率W Power W | 风量m3/h Air volume m3/h | 射程m Range m | 盘管kW*支 Coil kW * pcs | 水盘kW*支 Water tray kW * pcs | |
| GUDL501C | 6.7 | 4.6 | 3.2 | 1X∅500 | 1X414 | 5000 | 12 | 0.28*6 | 0.28*2 |
| GUDL501D | 8.1 | 5.6 | 4.3 | 1X∅500 | 1X460 | 4900 | 12 | 0.30*6 | 0.30*2 |
| GUDL501E | 9.8 | 6.7 | 5.4 | 1X∅500 | 1X460 | 4500 | 12 | 0.30*8 | 0.30*2 |
| GUDL601E | 16.6 | 11.4 | 9.2 | 1X∅600 | 1X780 | 7500 | 15 | 0.40*8 | 0.4*2 |
| GUDL502D | 22.2 | 15.3 | 11.8 | 2X∅500 | 2X460 | 11500 | 13 | 0.72*6 | 0.72*2 |
| GUDL602D | 28.9 | 19.9 | 14.7 | 2X∅600 | 2X780 | 16500 | 16 | 0.72*10 | 0.72*2 |
| GUDL602E | 33.8 | 23.3 | 18.4 | 2X∅600 | 2X780 | 15200 | 16 | 0.72*10 | 0.72*2 |
| GUDL602F | 37.8 | 26.1 | 22.1 | 2X∅600 | 2X780 | 14500 | 16 | 0.72*10 | 0.72*2 |
| GUDL632D | 40.7 | 28.1 | 23.7 | 2X∅630 | 2X800 | 19000 | 19 | 0.95*10 | 0.95*2 |
| GUDL632E | 44.1 | 30.4 | 26.9 | 2X∅630 | 2X800 | 18000 | 19 | 0.87*12 | 0.87*4 |
| GUDL603F | 54.5 | 37.6 | 32.3 | 3X∅600 | 3X780 | 20500 | 17 | 1.03*12 | 1.03*4 |
| GUDL633F | 66.8 | 46.1 | 38.8 | 3X∅630 | 3X800 | 25500 | 20 | 1.03*14 | 1.03*4 |
Technical parameters of efficient air cooler of electric defrosting
ceiling Spacing: 6.0mm
| Model | Refrigerating capacity kW | Tube volume | Fan parameters | Defrosting (electric heating) | ||||||
| SC1 | SC2 | SC3 | dm3 | Number X diameter of fans | Power W | Air volume m3/h | Range m | Coil kW * pcs | Water tray kW * pcs | |
| GUDD501C | 5.6 | 4.0 | 3.2 | 3.2 | 1X∅500 | 1X414 | 5200 | 12 | 0.28*8 | 0.28*2 |
| GUDD501D | 7.1 | 5.1 | 4.0 | 4.3 | 1X∅500 | 1X460 | 5100 | 12 | 0.30*8 | 0.30*2 |
| GUDD501E | 8.2 | 5.9 | 4.6 | 5.4 | 1X∅500 | 1X460 | 4800 | 12 | 0.30*10 | 0.30*2 |
| GUDD601E | 14.4 | 10.3 | 8.1 | 9.2 | 1X∅600 | 1X780 | 8200 | 15 | 0.40*10 | 0.4*2 |
| GUDD502D | 18.3 | 13.1 | 10.3 | 11.8 | 2X∅500 | 2X460 | 12000 | 13 | 0.72*8 | 0.72*2 |
| GUDD602D | 24.1 | 17.2 | 13.6 | 14.7 | 2X∅600 | 2X780 | 17000 | 16 | 0.72*12 | 0.72*2 |
| GUDD602E | 29.1 | 20.8 | 16.4 | 18.4 | 2X∅600 | 2X780 | 16400 | 16 | 0.72*12 | 0.72*2 |
| GUDD602F | 32.1 | 22.9 | 18.1 | 22.1 | 2X∅600 | 2X780 | 15500 | 16 | 0.72*12 | 0.72*2 |
| GUDD632D | 33.7 | 24.1 | 19.0 | 23.7 | 2X∅630 | 2X800 | 20000 | 19 | 0.95*12 | 0.95*2 |
| GUDD632E | 37.2 | 26.6 | 21.0 | 26.9 | 2X∅630 | 2X800 | 19000 | 19 | 0.87*12 | 0.87*4 |
| GUDD603F | 46.8 | 33.4 | 26.4 | 32.3 | 3X∅600 | 3X780 | 22000 | 17 | 1.03*12 | 1.03*4 |
| GUDD633F | 56.7 | 40.5 | 32.0 | 38.8 | 3X∅630 | 3X800 | 26500 | 20 | 1.03*14 | 1.03*4 |
Technical parameters of efficient air cooler of electric defrosting ceiling Spacing: 9.0mm
| Model | Refrigerating capacity kW | Tube capacity | Fan parameters | Defrosting (electric heating) | ||||||
| SC3 | SC4 | SC5 | dm3 | Number X diameter of fans | Power W | Air volume m3/h | Range m | Coil kW * pcs | Water tray kW * pcs | |
| GUDJ501C | 2.5 | 2.0 | 1.9 | 3.2 | 1X∅500 | 1X414 | 5300 | 12 | 0.28*8 | 0.28*2 |
| GUDJ501D | 3.3 | 2.6 | 2.5 | 4.3 | 1X∅500 | 1X460 | 5500 | 12 | 0.30*8 | 0.30*2 |
| GUDJ501E | 3.7 | 3.0 | 2.9 | 5.4 | 1X∅500 | 1X460 | 5100 | 12 | 0.30*10 | 0.30*2 |
| GUDJ601E | 6.5 | 5.2 | 5.0 | 9.2 | 1X∅600 | 1X780 | 8300 | 15 | 0.40*10 | 0.4*2 |
| GUDJ502D | 8.3 | 6.6 | 6.3 | 11.8 | 2X∅500 | 2X460 | 12500 | 13 | 0.72*8 | 0.72*2 |
| GUDJ602D | 10.8 | 8.5 | 7.8 | 14.7 | 2X∅600 | 2X780 | 17500 | 16 | 0.72*12 | 0.72*2 |
| GUDJ602E | 13.3 | 10.6 | 10.2 | 18.4 | 2X∅600 | 2X780 | 17000 | 16 | 0.72*12 | 0.72*2 |
| GUDJ602F | 14.5 | 11.6 | 11.1 | 22.1 | 2X∅600 | 2X780 | 16000 | 16 | 0.72*12 | 0.72*2 |
| GUDJ632D | 15.8 | 12.6 | 12.1 | 23.7 | 2X∅630 | 2X800 | 21000 | 19 | 0.95*12 | 0.95*2 |
| GUDJ632E | 17.7 | 14.1 | 13.5 | 26.9 | 2X∅630 | 2X800 | 20500 | 19 | 0.87*12 | 0.87*4 |
| GUDJ603F | 21.4 | 17.1 | 16.4 | 32.3 | 3X∅600 | 3X780 | 23000 | 17 | 1.03*12 | 1.03*4 |
| GUDJ633F | 25.4 | 20.3 | 19.5 | 38.8 | 3X∅630 | 3X800 | 27000 | 20 | 1.03*14 | 1.03*4 |
Overall dimensions and installation size of efficient air cooler of
electric defrosting ceiling Spacing: 4.5mm
| Model | Interface specification (mm) | Overall dimensions B*T*H | Installation Dimensions | weights | Outline icon | |||||
| Inlet pipe/return pipe | Drainage (inches) | L * W* H (mm): 610* 1,250*1,040 | L | E1 | E2 | E3 | F | kg | ||
| GUDL501C | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 36 | A |
| GUDL501D | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 38 | A |
| GUDL501E | ∅12/∅22 | G1 | 952*490*674 | 430 | 640 | / | / | 126 | 44 | A |
| GUDL601E | ∅16/∅28 | G1 | 1172*490*831 | 430 | 860 | / | / | 126 | 56 | A |
| GUDL502D | ∅16/∅35 | G1 | 1992*400*680 | 340 | 840 | 840 | / | 126 | 80 | B |
| GUDL602D | ∅22/∅42 | G1-1/2 | 1992*400*831 | 340 | 840 | 840 | / | 126 | 95 | B |
| GUDL602E | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 115 | B |
| GUDL602F | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 125 | B |
| GUDL632D | ∅22/∅42 | G1-1/2 | 2552*400*984 | 340 | 1120 | 1120 | / | 126 | 144 | B |
| GUDL632E | ∅22/∅42 | G1-1/2 | 2352*490*984 | 430 | 1020 | 1020 | / | 126 | 160 | B |
| GUDL603F | ∅25/∅50 | G1-1/2 | 2751*490*831 | 430 | 813 | 813 | 813 | 126 | 166 | C |
| GUDL633F | ∅25/∅50 | G2 | 2751*490*984 | 430 | 813 | 813 | 813 | 126 | 196 | C |
Overall dimensions and installation size of efficient air cooler of electric defrosting ceiling Spacing: 6.0mm
| Model | Interface specification (mm) | Overall dimensions B*T*H | Installation Dimensions | weights | Outline icon | |||||
| Inlet pipe/return pipe | Drainage (inches) | L * W* H (mm): 610* 1,250*1,040 | L | E1 | E2 | E3 | F | kg | ||
| GUDD501C | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 35 | A |
| GUDD501D | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 37 | A |
| GUDD501E | ∅12/∅22 | G1 | 952*490*674 | 430 | 640 | / | / | 126 | 43 | A |
| GUDD601E | ∅16/∅28 | G1 | 1172*490*831 | 430 | 860 | / | / | 126 | 57 | A |
| GUDD502D | ∅16/∅35 | G1 | 1992*400*680 | 340 | 840 | 840 | / | 126 | 78 | B |
| GUDD602D | ∅22/∅42 | G1-1/2 | 1992*400*831 | 340 | 840 | 840 | / | 126 | 93 | B |
| GUDD602E | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 112 | B |
| GUDD602F | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 122 | B |
| GUDD632D | ∅22/∅42 | G1-1/2 | 2552*400*984 | 340 | 1120 | 1120 | / | 126 | 140 | B |
| GUDD632E | ∅22/∅42 | G1-1/2 | 2352*490*984 | 430 | 1020 | 1020 | / | 126 | 154 | B |
| GUDD603F | ∅25/∅50 | G1-1/2 | 2751*490*831 | 430 | 813 | 813 | 813 | 126 | 162 | C |
| GUDD633F | ∅25/∅50 | G2 | 2751*490*984 | 430 | 813 | 813 | 813 | 126 | 192 | C |
Overall dimensions and installation size of efficient air cooler of
electric defrosting ceiling Spacing: 9.0mm
| Model | Interface specification (mm) | Overall dimensions B*T*H | Installation Dimensions | weights | Outline icon | |||||
| Inlet pipe/return pipe | Drainage (inches) | L * W* H (mm): 610* 1,250*1,040 | L | E1 | E2 | E3 | F | kg | ||
| GUDJ501C | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 34 | A |
| GUDJ501D | ∅12/∅22 | G3/4 | 952*400*674 | 340 | 640 | / | / | 126 | 36 | A |
| GUDJ501E | ∅12/∅22 | G1 | 952*490*674 | 430 | 640 | / | / | 126 | 42 | A |
| GUDJ601E | ∅16/∅28 | G1 | 1172*490*831 | 430 | 860 | / | / | 126 | 55 | A |
| GUDJ502D | ∅16/∅35 | G1 | 1992*400*680 | 340 | 840 | 840 | / | 126 | 76 | B |
| GUDJ602D | ∅22/∅42 | G1-1/2 | 1992*400*831 | 340 | 840 | 840 | / | 126 | 94 | B |
| GUDJ602E | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 114 | B |
| GUDJ602F | ∅22/∅42 | G1-1/2 | 1992*490*831 | 430 | 840 | 840 | / | 126 | 121 | B |
| GUDJ632D | ∅22/∅42 | G1-1/2 | 2552*400*984 | 340 | 1120 | 1120 | / | 126 | 139 | B |
| GUDJ632E | ∅22/∅42 | G1-1/2 | 2352*490*984 | 430 | 1020 | 1020 | / | 126 | 160 | B |
| GUDJ603F | ∅25/∅50 | G1-1/2 | 2751*490*831 | 430 | 813 | 813 | 813 | 126 | 162 | C |
| GUDJ633F | ∅25/∅50 | G2 | 2751*490*984 | 430 | 813 | 813 | 813 | 126 | 190 | C |
3. Product Outline View



Note 1: Design Criteria
| Standard heat exchange conditions | Inlet air temperature | Evaporation temperature | Relative humidity | Moisture absorption coefficient | Degree of superheat |
| SC1 | 10℃ | 0℃ | 85% | 1.35 | 6.5K |
| SC2 | 0℃ | -8℃ | 85% | 1.15 | 5.2K |
| SC3 | -18℃ | -25℃ | 95% | 1.05 | 4.6K |
| SC4 | -25℃ | -31℃ | 95% | 1.01 | 3.9K |
| SC5 | -34℃ | -40℃ | 95% | 1.01 | 3.9K |
Note 2: Refrigerant conversion coefficient
| Refrigerant | Working conditions | R22 | R404A | R507 | R134a |
| Correction factor | SC1 | 0.95 | 1 | 1 | 0.93 |
| Correction factor | SC2 | 0.95 | 1 | 1 | 0.91 |
| Correction factor | SC3 | 0.95 | 1 | 1 | 0.85 |
|