Sign In | Join Free | My chinacomputerparts.com
chinacomputerparts.com
Products
Search by Category
Home > Measuring & Analysing Instrument Design Services >

IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L

Categories Environmental Test Chamber
Brand Name: Sinuo
Model Number: SN885-150L
Certification: Calibration Certificate(Cost Additional )
Place of Origin: China
MOQ: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 10 sets per month
Delivery Time: 45 Days
Packaging Details: Plywood Case
Temperature Range: -40℃ to +150℃
Temperature Fluctuation: ≤±1.0℃
Temperature Deviation: ±2.0℃
Temperature Uniformity: ≤2.0℃
Internal Dimensions: W500×H600×D500mm
External Dimensions: W950×H1870×D1500mm
Volume: 150L
Weight: Approximately 565kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L


High and low temperature rapid change test chamber


Product information:


This High and low temperature rapid change test chamber is designed and manufactured according to IEC60068-2-1, IEC60068-2-2, IEC60068-2-78 and IEC60068-2-30.
It is used to process cold, heat, humidity and dryness testing of raw materials and devices such as Parts and materials for electronic appliances, food, automobiles, rubber and plastic materials, metals and other products, such as optical fiber, LCD, crystal, inductor, PCB, battery, computer, mobile phone, rubber, plastic, etc. The purpose is to confirm the reliability of storage, transportation and use of products under high and low temperature rapid alternating humid heat environment.


Technical parameter:


Test Environment Conditions


· Ambient temperature: 5~35°C

· Relative humidity: ≤85% RH

· Air pressure: (86~106) kPa

Testing Method

Temperature test equipment

Wet heat test equipment (for wet heat type only)

Temperature Range-40℃~+150℃
Temperature Fluctuation≤±1.0℃ (≤±0.5℃, as per GB/T5170-2008 specification)
Temperature Deviation±2.0℃
Temperature Uniformity≤2.0℃
Temperature Rise Time-40°C to +150°C, linear rate ≥ 15°C/min (no load)
Temperature Drop Time+150°C to -40°C, linear rate ≥ 15°C/min (no load)
Controller Model7-inch
Operating ModeProgram mode, fixed value mode
Setting MethodEnglish menu, touch input
Setting RangeTemperature: Adjusted according to the device's operating temperature range (Upper limit +5℃, Lower limit -5℃)
Display Resolution

· Temperature: 0.01℃

· Time: 0.01 minutes

InputPT100 thermistor (platinum resistance/voltage/current, etc., as required by the device)
Control MethodTemperature uses anti-integral-saturation PID with auto-tuning function

Structural Systems:


Insulation Enclosure Structure

Outer Wall Material: 1.2mm double-sided electrolytic plate, surface spray-painted

Inner Wall Material: 1.0mm stainless steel plate SUS304

Box Insulation Material: Rigid polyurethane foam + rock wool

Door Insulation Material: Rock wool

Air Regulation Channel

Axial Flow Fans: 2 unitsHeaters, Evaporator (also functions as dehumidifier),Water Drainage and Supply Ports,Dry Bulb,Temperature Sensor

For Wet Heat Type: Includes humidifier, dry-burn protection, wet bulb temperature sensor

Standard Configuration of Test Chamber

Observation Window: Transparent electric heat film, double-glazed tempered glass (1 unit, located on the door)

Visible Area: W430mm × H550mm (including lighting and obstruction areas, as shown in the device outline diagram)

Lead Hole: φ50mm (1 unit on each side of the box)

Sample Rack: Stainless steel, 2-tier, load capacity (evenly distributed): 20kg per tier

Lighting: 7W/DC24V (1 unit)

Mobile Casters: 4 units

Door

Single-opening Hinged Door: Left hinge, right handle

Includes Observation Window, Lighting, and Defogging Heater for Window/Frame

Control Panel

Temperature control display screen

Over-temperature protection setting device

Emergency stop switch

Operation indicator light

Fault indicator light

Buzzer

Mechanical RoomIncludes: Refrigeration unit, drainage system, fan, power distribution control cabinet,Humidification and humidity measurement control devices
Power Distribution Control Cabinet

Cooling fan

Power distribution board

RS-485 physical interface

Main power circuit breaker

Heaters

Material: 316 stainless steel armored heating element

Control Method: Non-contact pulse width modulation, SSR (Solid-State Relay)



China IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L factory
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0