Temperature transmitter iTEMP TMT31 for accurate and reliable RTD measurements
4-20 mA temperature transmitter as head or DIN rail device with one RTD or one TC sensor input suitable for use in zone 2 (Ex ec) / Div. 2 areasField of application
The iTEMP TMT31 is a reliable, long-term stable, single-channel 4
to 20 mA temperature transmitter for thermometers with terminal
head Form B suited for use in Zone 2 / Div. 2 areas. Individual
transmitter-sensor matching with Callendar-Van Dusen linearization
further improves your temperature measurement accuracy for RTD
sensors. Push-in terminals for quick wiring facilitate
installation. The device is available pre-configured or can easily
be parametrized using free software tools.
Benefits
Application examples
1. A sensor (RTD or thermocouple) with transmitter in remote installation via DIN rail transmitter
2. Installed head transmitter - 1 x RTD/TC wired directly
Endress+Hauser offers a comprehensive range of industrial thermometers with resistance sensors or thermocouples. When combined with the temperature transmitter, these components form a complete measuring point for a wide range of applications in the industrial sector. The temperature transmitter is a 2-wire device with one measuring input and one analog output. It is used for instrumentation in terminal head form B (flat face) according to DIN EN 50446 or as a DIN rail device for installation in a cabinet on a mounting rail TH35 according to EN 60715.
Standard diagnostic functions
• Cable open-circuit, short-circuit of sensor wires
• Incorrect wiring
• Internal device errors
• Overrange and underrange detection
• Device temperature overrange/underrange detection
• Low voltage detection
Output simulation: Simulation of the 4 to 20 mA output signal
Output signal
Analog output: 4 to 20 mA, 20 to 4 mA (can be inverted)
Filter: 1st order digital filter: 0 to 120 s / Network frequency filter: 50/60 Hz (cannot be adjusted)
Switch-on delay:≤ 5 s, until the first valid measured value signal is present at the current output. While switch-on delay = Ia ≤ 3.8 mA
Supply voltage:
Values for non-hazardous areas, protected against polarity reversal: 10 V ≤ Vcc ≤ 36 V (standard) Values for hazardous area, see Ex documentation.
Galvanic isolation (TC):Galvanic isolation (TC)
Current consumption:3.5 to 22.5 mA
|   | 
 TMT187 head mounted temperature transmitter RTD TC input
                                                                                    
                        
                        
                        
                                                            TMT187 head mounted temperature transmitter RTD TC input
                                                    
                        
                     TMT189 head mounted temperature transmitter HART protocol 4 to 20mA
                                                                                    
                        
                        
                        
                                                            TMT189 head mounted temperature transmitter HART protocol 4 to 20mA
                                                    
                        
                     2 Wire Head Mounted Temperature Transmitter With HART And Isolation TMT192C
                                                                                    
                        
                        
                        
                                                            2 Wire Head Mounted Temperature Transmitter With HART And Isolation TMT192C
                                                    
                        
                     2wire TC Head mounted temperature transmitter industrial temperature transmitter TMT188B
                                                                                    
                        
                        
                        
                                                            2wire TC Head mounted temperature transmitter industrial temperature transmitter TMT188B
                                                    
                        
                     High accuracy Head mounted temperature transmitter TMT189 with HART
                                                                                    
                        
                        
                        
                                                            High accuracy Head mounted temperature transmitter TMT189 with HART
                                                    
                        
                     ITEMP TMT31 Head Mount Temperature Transmitter Rtd Pt100
                                                                                    
                        
                        
                        
                                                            ITEMP TMT31 Head Mount Temperature Transmitter Rtd Pt100
                                                    
                        
                     ITEMP TMT31 Head Mounted Temperature Transmitter Rtd Pt100 Pt1000
                                                                                    
                        
                        
                        
                                                            ITEMP TMT31 Head Mounted Temperature Transmitter Rtd Pt100 Pt1000
                                                    
                        
                     ITEMP TMT31 head mounted transmitter In Hazardous Areas
                                                                                    
                        
                        
                        
                                                            ITEMP TMT31 head mounted transmitter In Hazardous Areas
                                                    
                        
                     TMT31 Temperature Transmitters in Terminal Heads Form B
                                                                                    
                        
                        
                        
                                                            TMT31 Temperature Transmitters in Terminal Heads Form B
                                                    
                        
                     Endress Hauser Head Mounted Temperature Transmitter TMT182
                                                                                    
                        
                        
                        
                                                            Endress Hauser Head Mounted Temperature Transmitter TMT182