| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Edible Oil Testing Equipment | 
|---|---|
| Brand Name: | Shandong Shengtai Instrument | 
| Model Number: | ST006 | 
| Certification: | GB/T 10361-2008 | 
| Place of Origin: | CHINA | 
| MOQ: | 1 | 
| Payment Terms: | T/T | 
| Supply Ability: | 10000 sets/ year | 
| Delivery Time: | 7-15 work days | 
| Packaging Details: | wooden case | 
| Weight of stirring rod: | 25g±0.05g | 
| Viscosity tube size: | inner diameter d=21mm±0.02mm outer diameter D=23.8mm±0.25mm inner wall height h=220mm±0.3mm | 
| Heater power: | 600W | 
| Measurement error: | <5% | 
| Company Info. | 
| Shandong Shengtai instrument co.,ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
ST006A/B Falling number tester
ST006 Falling number tester .This product is suitable for the determination of A-amylase activity in cereals, flours and other starch-containing products,It is an important measuring instrument for quality verification in grain storage, flour processing, food processing and other fields.
This instrument is in accordance with the Hagbery-Perten method to determine the activity index of a-amylase in grain and flour, and implements GB/T 10361-2008 "Grain Landing Numerical Determination Method" in line with the national standard. The principle of this method is to use the principle of a-amylase on the liquefaction and decomposition of gelatinized starch to determine the activity of enzymes, and the viscosity of the gelatinized liquid decreases significantly after liquefaction and decomposition, so the content of the enzyme can be reflected according to the change of viscosity.
The small drop value and low viscosity indicate strong enzyme activity. In the process of raw grain purchase trade and procurement, the use of landing numerical instrument to detect grain crops, according to the size of the landing value for separate warehouses, according to the quality of the price, refuse to accept malt wheat, will bring you unexpected benefits.
Falling number test
Technical features:
1. The key switch of this instrument adopts membrane soft key switch, which has a long service life. Other units use the ship-type model, this switch is used more times, easy to button failure, need to be replaced.
2. The control part of the instrument adopts intelligent single-chip microcomputer control technology, and uses a prompt light to indicate the next operation, which is more convenient to use.
Technical conditions:
| Weight of stirring rod | 25g±0.05g | 
| Viscosity tube size | inner diameter d=21mm±0.02mm outer diameter D=23.8mm±0.25mm inner wall height h=220mm±0.3mm | 
| Heater power | 600W | 
| Measurement error | <5% | 
ST006 Falling number tester .This product is suitable for the determination of A-amylase activity in cereals, flours and other starch-containing products,It is an important measuring instrument for quality verification in grain storage, flour processing, food processing and other fields.
This instrument is in accordance with the Hagbery-Perten method to determine the activity index of a-amylase in grain and flour, and implements GB/T 10361-2008 "Grain Landing Numerical Determination Method" in line with the national standard. The principle of this method is to use the principle of a-amylase on the liquefaction and decomposition of gelatinized starch to determine the activity of enzymes, and the viscosity of the gelatinized liquid decreases significantly after liquefaction and decomposition, so the content of the enzyme can be reflected according to the change of viscosity.
The small drop value and low viscosity indicate strong enzyme activity. In the process of raw grain purchase trade and procurement, the use of landing numerical instrument to detect grain crops, according to the size of the landing value for separate warehouses, according to the quality of the price, refuse to accept malt wheat, will bring you unexpected benefits.
|   | 
 Palm oil and peanut oil detection instrument ST149 fully automatic oil oxidation stability tester
                                                                                    
                        
                        
                        
                                                            Palm oil and peanut oil detection instrument ST149 fully automatic oil oxidation stability tester
                                                    
                        
                     NMR Edible Oil Testing Equipment Oil Content Tester Using Nuclear Magnetic Resonance
                                                                                    
                        
                        
                        
                                                            NMR Edible Oil Testing Equipment Oil Content Tester Using Nuclear Magnetic Resonance
                                                    
                        
                     Power 220V 2.5-10 High Temp Ash Separation Furnace Resistance Furnace 8KW Rated Temp 1000℃
                                                                                    
                        
                        
                        
                                                            Power 220V 2.5-10 High Temp Ash Separation Furnace Resistance Furnace 8KW Rated Temp 1000℃
                                                    
                        
                     Wavelength Accuracy ±5nm 721  Spectrophotometer Bandwidth 5nm Stray Light At 360nm ≤0.5%T
                                                                                    
                        
                        
                        
                                                            Wavelength Accuracy ±5nm 721  Spectrophotometer Bandwidth 5nm Stray Light At 360nm ≤0.5%T
                                                    
                        
                     Automatic Plant Oil Oxidation Stability Index OSI Accordance With ISO 6886
                                                                                    
                        
                        
                        
                                                            Automatic Plant Oil Oxidation Stability Index OSI Accordance With ISO 6886
                                                    
                        
                     compact Studio Diameter 110mm ST005E Automatic Hammer Cyclone Mill Crushing Equipment
                                                                                    
                        
                        
                        
                                                            compact Studio Diameter 110mm ST005E Automatic Hammer Cyclone Mill Crushing Equipment
                                                    
                        
                     Heating Hot Plate Crude Fat Analyzer Fat Extractor Solvent Reclaim Rate ≥ 80%
                                                                                    
                        
                        
                        
                                                            Heating Hot Plate Crude Fat Analyzer Fat Extractor Solvent Reclaim Rate ≥ 80%
                                                    
                        
                     Centrifugal Time 1min Double Head Gluten Meter Agitator Rotation Speed 120±2r/Min
                                                                                    
                        
                        
                        
                                                            Centrifugal Time 1min Double Head Gluten Meter Agitator Rotation Speed 120±2r/Min
                                                    
                        
                     Distiller 800W kjeldahl nitrogen analyzer 8 Holes Azotometer Power 1500W
                                                                                    
                        
                        
                        
                                                            Distiller 800W kjeldahl nitrogen analyzer 8 Holes Azotometer Power 1500W
                                                    
                        
                     Minimum Reading 0.001° 0.01°Z  Automatic Sugar Detector Repeatability ≤0.002 ± 0.006Z
                                                                                    
                        
                        
                        