| Specifications: | | | |
| General | | | |
| Maximum voltage between any Terminal and Earth Ground | | |
| AC | 1000 V | | |
| DC | 1500 V | | |
| Batteries | 2 AA IEC LR6 alkaline | | |
| Display | Dual display with backlight | | |
| Automatic Power Off | 20 minutes | | |
| Electrical | | | |
| Accuracy | | | |
| Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %.
Accuracy specifications take the form of: ±([% of Reading] +
[Number of Least Significant Digits]). |
| Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
| AC Current: Jaw | | | |
| Range | 999.9 A | | |
| Resolution | 0.1 A | | |
| Accuracy | 2 % + 5 digits (10 Hz to 100 Hz) | |
| 2.5 % + 5 digits (100 Hz to 500 Hz) | |
| Crest Factor (50/60 Hz) | 2.5 @600.0 A | | |
| 3.0 @500.0 A | | |
| 1.42 @999.9 A | | |
| Add 2 % for C.F. >2 | | |
| AC Current: Flexible Current Probe | | | |
| Range | 999.9 A | | |
| 2500 A | | |
| Resolution | 0.1 A (≤999.9 A) | | |
| 1 A (≤2500 A) | | |
| Accuracy | 3 % RD + 5 digits (10 Hz to 500 Hz) | |
| Crest Factor (50/60Hz) | 2.5 @1400 A | | |
| 3.0 @1100 A | | |
| 1.42@2500 A | | |
| Add 2 % for C.F. >2 | | |
| Position Sensitivity | | | |
 |
| Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error |
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5 % |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0 % |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at
optimum position, no external electrical or magnetic field, and
within operating temperature range. |
| | | |
| DC Current | | | |
| Range | 999.9 A | | |
| Resolution | 0.1 A | | |
| Accuracy | 2 % RD + 5 digits[1] | | |
| [1] When using the ZERO (B) function to compensate for offsets. |
| AC Voltage | | | |
| Range | 600.0 V | | |
| 1000 V | | |
| Resolution | 0.1 V (≤600.0 V) | | |
| 1 V (≤1000 V) | | |
| Accuracy | 1 % RD + 5 digits (20 Hz to 500 Hz) | |
| DC Voltage | | | |
| Range | 600.0 V | | |
| 1500 V | | |
| Resolution | 0.1 V (≤600.0 V) | | |
| 1 V (≤1500 V) | | |
| Accuracy | 1 % RD + 5 digits | | |
| mV dc | | | |
| Range | 500.0 mV | | |
| Resolution | 0.1 mV | | |
| Accuracy | 1 % RD + 5 digits | | |
| Amps Frequency: Jaw | | | |
| Range | 5.0 Hz to 500.0 Hz | | |
| Resolution | 0.1 Hz | | |
| Accuracy | 0.5 % RD + 5 digits | | |
| Trigger Level | 5 Hz to 10 Hz, ≥10 A | | |
| 10 Hz to 100 Hz, ≥5 A | | |
| 100 Hz to 500 Hz, ≥10 A | | |
| Amps Frequency: Flexible Current Probe | | | |
| Range | 5.0 Hz to 500.0 Hz | | |
| Resolution | 0.1 Hz | | |
| Accuracy | 0.5 % RD + 5 digits | | |
| Trigger Level | 5 Hz to 20 Hz, ≥25 A | | |
| 20 Hz to 100 Hz, ≥20 A | | |
| 100 Hz to 500 Hz, ≥25 A | | |
| Voltage Frequency | | | |
| Range | 5.0 Hz to 500.0 Hz | | |
| Resolution | 0.1 Hz | | |
| Accuracy | 0.5 % RD + 5 digits | | |
| Trigger Level | 5 Hz to 20 Hz, ≥5 V | | |
| 20 Hz to 100 Hz, ≥5 V | | |
| 100 Hz to 500 Hz, ≥10 V | | |
| DC Power | | | |
| Range | 600.0 kVA (600.0 V dc range) | | |
| 1500 kVA (1500 V dc range) | | |
| Resolution | 0.1 kVA | | |
| 1 kVA | | |
| Accuracy | 2 % RD + 2.0 kVA | | |
| 2 % RD + 20 kVA | | |
| Resistance | | | |
| Range | 600.0 Ω | | |
| 6000 Ω | | |
| 60.00 kΩ | | |
| Resolution | 0.1 Ω (≤600.0 Ω) | | |
| 1 Ω (≤6000 Ω) | | |
| 0.01 kΩ (≤60.00 kΩ) | | |
| Accuracy | 1 % RD + 5 digits | | |
| Capacitance | | | |
| Range | 100.0 μF | | |
| 1000 μF | | |
| Resolution | 0.1 μF (≤100.0 μF) | | |
| 1 μF (≤1000 μF) | | |
| Accuracy | 1 % RD + 5 digits | | |
| Inrush Trigger Level | 5 A | | |
| Mechanical | | | |
| Size (L x W x H) | 281 mm x 84 mm x 49 mm | | |
| Weight (with batteries) | 520 g | | |
| Jaw Opening | 34 mm | | |
| Flexible Current Probe Diameter | 7.5 mm | | |
| Flexible Current Probe Cable Length | | | |
| (head to electronics connector) | 1.8 m | | |
| Environmental | | | |
| Operating Temperature | -10 °C to 50 °C | | |
| Storage Temperature | -40 °C to 60 °C | | |
| Operating Humidity | Non condensing (<10°C) | | |
| ≤90 % RH (at 10 °C to 30 °C) | | |
| ≤75 % RH (at 30 °C to 40 °C) | | |
| ≤45 % RH (at 40 °C to 50 °C) | | |
| Operating Altitude | 2000 m | | |
| Storage Altitude | 12 000 m | | |
| Ingress Protection (IP) Rating | IEC 60529: IP54 non-operating | | |
| Electromagnetic Compatibility (EMC) | | | |
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A |
| Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary for
the internal function of the equipment itself. |
| Class A: Equipment is suitable for use in all establishments other
than domestic and those directly connected to a low-voltage power
supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted and radiated
disturbances. |
| Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to radio
reception in such environments. |
| Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
| Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user should take
notice of it. This equipment is intended for use in business
environments and not to be used in homes. |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device
per clause 15.103. |
| Safety | | | |
| General | IEC 61010-1, Pollution Degree 2 | |
| Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V | |
| IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V | |
| Wireless Radio | | | |
| Radio frequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE | |
| Wireless Radio Frequency Range | 2400 MHz to 2483.5 MHz | | |
| Output Power | <100 mW | | |
| SIMPLIFIED EU DECLARATION OF CONFORMITY | | |
| Hereby, Fluke declares that the radio equipment contained in this
Product is in compliance with Directive 2014/53/EU. |