CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable

Categories Gas Mass Flow Meter Controller Flow Meter
Brand Name: Consensic
Model Number: CAFS5006
Place of Origin: WUXI
MOQ: Please contact us for details
Price: Offline conversation or face-to-face discussion
Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
Supply Ability: 999
Delivery Time: 3-7 work days
Ingress protection: IP40
communication mode: 485/I2c selectable
interface: G3/8
Output mode: Analog output 1-5V
precision: ±1.5%F.S
Storage Temperature: 25°C - 80°C
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable

Product Description for CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable

CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable is a versatile and high-performance flow measurement device designed for a range of applications. This advanced flow meter offers multiple configurations and features tailored to meet diverse measurement needs, making it suitable for both industrial and automotive environments.


Product Features

  • Advanced Communication Modes
    The CAFS5006 Series supports RS485 and I2C communication protocols, allowing for flexible integration into various systems and easy data transfer.

  • Customizable Response Time
    Offers a selectable response time of 20 ms, which can be adjusted based on the specific requirements of your application for faster or slower flow measurements.

  • Wide Flow Measurement Range
    The flow meter supports a customizable flow range of 20/50/100/200/300 SLPM, suitable for different applications from small-scale to larger flow measurements.

  • High Measurement Accuracy
    Provides accurate measurements with an accuracy of ±1.5% FS, ensuring reliable data for process control and monitoring.

  • Flexible Power Supply Options
    Operates over a wide voltage range of 8 to 24 VDC with a low current consumption of 50 mA, accommodating different power supply configurations.

  • High Pressure Tolerance
    Capable of withstanding a maximum pressure of 0.8 MPa, with customizable specifications to suit various industrial requirements.

  • Multiple Output Options
    Features analog outputs (1-5 VDC) for easy integration into existing systems and for direct measurement readings.

  • Durable Construction
    Built from aluminum alloys with an optional stainless steel construction for enhanced durability and resistance to harsh environments.

  • High Protection Level
    With an IP40 protection rating, the CAFS5006 Series is designed to perform reliably in challenging conditions.

  • Versatile Calibration Method
    Calibrated with air at 0°C and 20°C, 101.325 kPa, ensuring accurate and consistent performance across different conditions.

  • User-Friendly Design
    G3/8 connection mode for easy installation and integration into existing systems.

Performance Parameters

Functional ItemsCAFS5006 Series Mass Flow Meter
Flow Range20 / 50 / 100 / 200 / 300 SLPM (customizable)
Power Supply Voltage8~24 VDC, 50 mA
Accuracy±1.5% FS
Response Time20 ms (selectable)
Maximum Pressure0.8 MPa (customizable)
Communication ModeRS485 / I2C (selectable)
Output MethodAnalog Output of 1-5 VDC
Temperature RangeMedium Temperature: -10°C to 65°C
Protection LevelIP40
Calibration MethodAir, 0°C and 20°C at 101.325 kPa
MaterialAluminum Alloys (Stainless Steel Optional)
Connection ModeG3/8 (customizable)

Applications

  • Industrial Process Control
    Ideal for measuring gas flow in various industrial processes, ensuring accurate control and monitoring.

  • Automotive Testing
    Suitable for use in automotive applications for testing and calibrating fuel injection systems and other components.

  • Environmental Monitoring
    Provides reliable flow measurements for environmental control and research applications.

  • Energy Sector
    Used for flow measurement in energy production processes, contributing to efficient energy management.

Pin Configuration

PinFunction
1NTC (Temperature Sensor) / Empty
2VCC (Power Supply)
3GND (Signal Ground)
4NC (No Connection)
5Output (Flow Measurement Signal)

Note: The pin configuration may vary based on customer specifications. The above configuration represents a common setup for reference.

Storage Instructions

  • Storage Conditions: Store in a cool, ventilated, dry, and non-corrosive environment.
  • Storage Temperature: 25°C - 80°C.

Troubleshooting Guide

Fault PhenomenonPossible CauseSolution
No Analog Signal① Wiring ErrorConnect wires correctly according to the instructions
No Traffic Change① Sensor DamageCheck if the sensor is damaged
② No Air Flow in the PipelineEnsure there is air flow in the pipeline
Communication Issues① Wiring ErrorVerify wiring according to the communication instructions
② Incorrect Parameter SettingsCorrectly set parameters according to the communication protocol

Model and Specifications

Product ModelLatus RectumJoggleLHWDSpecifications
CAFS 500661/4’’832735610 / 20 / 30 / 50 units (L / MIN)
China CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable factory