Sign In | Join Free | My chinacomputerparts.com
chinacomputerparts.com
Products
Search by Category
Home >

Coblation Plasma Surgery System For Turbinate Reduction And Turbinate Channeling

Categories ENT Coblator
Brand Name: Better
Model Number: VE02E
Certification: iso, Cfda
Place of Origin: China
MOQ: 68 pc
Price: 80-298USD
Payment Terms: L/C, T/T, MoneyGram
Supply Ability: 100000 sets per year
Packaging Details: Standard Carton
Similar Brand: Artrhocare
Function: Ablation,Cutting,Coagulation, Grasping,Peeling,Clamping and Suction
Technology: Coblation technology
Application: ENT Surgery, Turbinate Reduction and Channeling
High Light: rf ablation system, rf ablation devices,medical surgical instrument, disposable surgical instruments
Power Settings: Low, Medium, High
Electrode Materials: Tungsten, Titanium, Stainless Steel
Safety: High
Keywords: Coblation Plasma Surgery Wand
Safety Features: Automatic shutdown, Overload protection
Electrode Types: Standard, Precise, Micro
Feature: light pain
Mode: Radiofrequency Ablation
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Coblation Plasma Surgery System For Turbinate Reduction And Turbinate Channeling

Coblation Plasma Surgery System for Turbinate Reduction and Turbinate Channeling


Product Introduction


It is design specially for Tougue Root Ablation, Turbinate Reduction and Turbinate Channeling, and nasal cavity lesion tissue treatment. It has the function of cutting, ablation, hemostasis and coagulation. It is connect with SPK100 ENT plasma surgery system to perform the operation.


Product Tip Picture



Product Application


  • Repeated acute attacks of chronic tonsillitis;
  • A history of abscesses around the tonsils;
  • Excessive hypertrophy of the tonsils, preventing swallowing or breathing, or affecting eustachian tube function;
  • simple III degree hypertrophy or near III degree hypertrophy tonsils;
  • Patients with rheumatic fever, nephritis, arthritis, and rheumatic heart disease who have suspected tonsils as the lesion;
  • Benign tonsil tumors.

Product Advanatages


  • Safety: Compared with traditional surgical methods (such as: electric knife, laser), the current does not flow through the human body, the working surface temperature is only 40 ° C to 70 ° C, and the surrounding tissue is less thermally damaged. When used in the recommended energy range, the cutting and ablation depth is controlled to ≤50μm.
  • Minimally Invasive: Compared with traditional surgical methods (such as electric knife, laser), it has less heat, reduces tissue thermal damage, reduces wound healing time, reduces wound bleeding and scar formation
  • High Efficiency: Compared with traditional surgical methods (such as: electric knife, laser), the patient's pain during surgery is significantly reduced, and the incidence of postoperative inflammation is significantly reduced. During the surgery, the doctor stops bleeding while cutting, and does not need other hemostasis tools.

System Set Up


DescriptionRemark
Manufacturer LogoBETTER Brand.
Working Frequency50Hz
Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment HandleConnects with the treatment accessories.
Power SwitchSystem start power button. “O” means power off; “I” means power on.
ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

Anesthesia


General anesthesia Or Local anesthesia


Cutting Principle


Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.


Treatment Diseases


Ablation and Channeling the soft tissue at narrow spaces like nasal cavity.


Storage Condition


Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.

Workshop:

China Coblation Plasma Surgery System For Turbinate Reduction And Turbinate Channeling factory
Send your message to this supplier
 
*From:
*To: Better Health Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0