Sign In | Join Free | My chinacomputerparts.com |
|
Categories | Transformer Drying Oven |
---|---|
Brand Name: | JC |
Model Number: | 8245 |
Certification: | SGS,CE,UL |
Place of Origin: | China |
MOQ: | 1 pcs |
Price: | consult |
Payment Terms: | L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/month |
Delivery Time: | 5 days |
Packaging Details: | Export standard packaging |
Driven Type: | Electric |
Transport Package: | Wooden |
Production Capacity: | 60000PCS/Year |
Specification: | 300*300*300 |
Installation: | Vertical |
Air Circulation: | Forced Air |
Control System: | Digital Display |
Heating Element: | Stainless Steel |
Material: | Stainless Steel |
Noise: | ≤60dB |
Power: | 220V/50Hz |
Size: | Large |
Temperature Range: | 0-400°C |
Timer: | 0-999min |
Voltage: | 220V/50Hz |
Weight: | 50kg |
Company Info. |
Wuxi Jiachen Power Electronics Equipment Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
The Oven used for Drying of Castable Insulating Parts, Impregnated Insulating Parts, Drying of Fiber Insulating Parts
Equipment advantages
Install a hot air circulation channel on the inner wall, ensuring uniform indoor air temperature;
High degree of automation, capable of setting different process curves according to the requirements of different products;
High temperature control accuracy, automatically stopping heating when reaching the set temperature.
The curing drying oven is mainly used for the drying and curing of casting insulation parts, impregnation insulation parts, and fiber insulation parts. We can design and manufacture various types of drying ovens according to user requirements.
Brief introduction
HG series transformer/insulation parts curing furnace is suitable
for the curing of transformer's epoxy resin and the preheating
(predrying) of coil and mould.
This series of products can be designed as two or more sets of
connected structure, compact and beautiful. The machine is
excellent in its temperature uniformity and has a unique hot air
circulation mode, which can be applied to different process of
transformer curing.
performance
Parameter | HG-1 | HG-2 | HG-3 | HG-4 | HG-5 |
Dimension of working chamber(width×depth×height) mm | 550×450×550 | 850×800×1000 | 1500×1000×1500 | 1900×800×1500 | 1700×1800×2000 |
Operating temperature(ºC) | Indoor temperature-200 | Indoor temperature-200 | Indoor temperature-200 | Indoor temperature-200 | Indoor temperature-200 |
Operating voltage/ frequency(V/ Hz) | 3-380/50 | 3-380/50 | 3-380/50 | 3-380/50 | 3-380/50 |
Heating power(kw) | 4 | 10.5 | 18 | 21 | 36 |
Temperature uniformity(%) | ±2.5 | ±2.5 | ±2.5 | ±2.5 | ±2.5 |
Temperature fluctuation(ºC) | ±1 | ±1 | ±1 | ±1 | ±1 |
Note: Non-standard product can be designed and manufactured in accordance with the requirement of the user. |
![]() |