Brand Name: Endress+Hauser
Model Number: FMU90-R11CA131AA3A
Certification: ATEX, CSA
Place of Origin: Germany
MOQ: 1 piece
Price: negotiable
Payment Terms: T/T
Supply Ability: 100pcs per month
Delivery Time: on request
Packaging Details: standard carton packing
Specialities: Protection Class IP 66 / NEMA 4x automatic sensor recognition of FDU9x sensors option: flow measurement for open channel and weirs or additional pump control functions
Supply / Communication: 90 ... 253 VAC 10.5 ... 32 VDC up to 2x 4...20mA HART Profibus DP
Measuring principle: Ultrasonic
Characteristic / Application: Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
Accuracy: +/- 2mm + 0.17% of measured distance
Ambient temperature: -40 °C ... 60 °C (-40 °F ... 140 °F)
Communication: up to 2x 4 ... 20 mA HART Profibus DP
Components: Sensors FDU9x
Company Info.
SC Automation Limited
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IP66 Endress Hauser Ultrasonic Flow Meter Time Of Flight Prosonic FMU90-R11CA131AA3A

Endress Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU90-R11CA131AA3A


SPECIFICATIONS


  • Measuring principle:Ultrasonic

  • Characteristic / Application:Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version

  • Specialities:Protection Class IP 66 / NEMA 4x;automatic sensor recognition of FDU9x sensors option: flow measurement for open channel and weirs or additional pump control functions

  • Supply / Communication:90 ... 253 VAC;10.5 ... 32 VDC;up to 2x 4...20mA HART;Profibus DP

  • Accuracy:+/- 2mm + 0.17% of measured distance

  • Ambient temperature:-40 °C ... 60 °C(-40 °F ... 140 °F)

  • Communication:up to 2x 4 ... 20 mA HART Profibus DP

  • Certificates / Approvals:ATEX, CSA

  • Options:Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display

  • Components:Sensors FDU9x


Field of application

Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.

Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.

  • Calculations: Average, difference, sum

  • Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors

  • Flow measurement with back water or sludge detection

  • Up to 3 totalizers and 3 counters

  • Counting or time pulse output for control of external units

Benefits

Simple, menu-guided operation with 6-line plain text display, 15 languages selectable

Envelope curves on the display for quick and simple diagnosis

Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program

Time-of-Flight correction via integrated or external temperature sensors

Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs
pre-programmed and selectable

Online calculation of the flume-/weir-flows via integrated flow curves

Automatic detection of the sensors FDU9x

    Related Part Number:


    CUS71D-AA1A

    FMU42-APB2A22A

    FMU90-R11CA111AA3A

    FMU90-R11CA131AA3A

    COM253-WX0005

    COS61D-AAA1A3

    CPS11D-7BT2G

    FMU41-ARB2A2

    FMU30-AAHEAAGGF

    CPS11D-7AA21

    CPS71D-7TB21

    CPS12D-7NA21

    CPM223-PR0005

    CUS52D-AA1AA3

    FTL31-AA4U3BAWSJ

    CPS11D-7AS21

    COS61-A2F0

    CPS12D-7PA21

    CPF81D-7LH11

    CPS11D-7BA2G

    CPM253-PR0005

    51518598

    CM42-MEA000EAZ00

    CUS51D-AAD1A3

    CM442-AAM2A2F010A

    CM442-AAM1A2F011A+AK

    CYK10-G101

    CYK10-G051

    COY31-Z

    FMU30-AAHEABGHF

    COS61D-AAA1A4

    CYK10-E051

    CPS71D-7TB2G

    CLM253-CD0005

    CM442-AAM1A2F010A

    FTW31-A2A5AA0A+1 L:600MM

    CPS31-1AC2ESA

    CPS31-1EC2ESA

    DK9CM-2

    FTL41-AAA2AAAAA2CJAAAAJ L=1000MM

    CPS11-2AA2ESK

    FTM51-AGJ2L4A12AA L=2600MM

    PMP71-AAA2H21GAAAA

    CLM253-ID0005

    COV45-41TN1

    CPS11-2BA2ESA

    CPS77E-BA6BBU2

    CLM223-CD0520


    China IP66 Endress Hauser Ultrasonic Flow Meter Time Of Flight Prosonic FMU90-R11CA131AA3A factory
    Send your message to this supplier
     
    *From:
    *To: SC Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0