| Brand Name: | Cummins Power |
| Model Number: | FM800kw |
| Place of Origin: | CHINA |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | T/T |
| Supply Ability: | 1000 |
| Packaging Details: | Plywood Package |
| Certification: | ISO9001 |
| Air Compressor: | Integrated |
| Air Intake System: | Turbocharged |
| Alternator: | Brushless |
| Coolant Filter: | Full-Flow |
| Cooling System: | Liquid-Cooled |
| Emissions Compliance: | EPA Tier 4 Final/EU Stage IV |
| Engine Type: | Diesel |
| Exhaust System: | Aftertreatment |
| Fuel Filter: | Dual-Stage |
| Fuel System: | High-Pressure Common Rail |
| Governor System: | Electronic |
| Lubrication System: | Full-Flow |
| Oil Filter: | Full-Flow |
| Power Output: | Up to 2000 kW |
| Starting System: | Electric |
| Company Info. |
| Weifang Fengmao Power Equipment Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
| Helpful tips on Generator Set Fault | |||
| When fault occurs during generator set running,could do primary judgement according to following tips. | |||
| Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
| High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
| Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
| Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
| Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
| Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
| Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |




|