Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Categories Micro Data Center
Brand Name: lpsrits
Place of Origin: China
MOQ: 1 set of
Price: bargaining
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time: 8 working days
Packaging Details: The single row scheme of the micro module data center fully considers the standardized design, energy conservation and capacity expansion compatibility, and uses standardized power, refrigeration and cabinet units to help IT experts seamlessly plan, expand
cabenit quanity: LESS THAN 20
ITcabenit quanity: LESS THAN 20
POWER DENITISY -kW/CAbinet: less than15kW/CABINET
Redundancy style: N/N+1/2N
UPSCAPACITY -kVA: MAX90kVA
UPS: rack-mounted modular
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility

Advantages and characteristics


VMDC-06-RRS
cabenit: 1*Integrated cabinet+ 1*IT cabenit

UPS: 6kVA rack-mounted
cooling: 5.6kW InRow air-conditioner

Redundancy:N


VMDC-10-RRS
cabenit 1*Integrated cabinet+ 2*ITcabenit

UPS: 10+10(kVA)rack-mounted

cooling: 7.6+7.6kWInRow air-conditioner

Redundancy: N+1


VMDC-20-RRS
cabenit: 1*Integrated cabinet+ 4*ITcabenit

UPS: 20+20(kVA)rack-mounted

cooling: 17.6+17.6kW InRow air-conditioner

Redundancy: N+1


VMDC-30-RRS
cabenit: 1*Integrated cabinet+ 6*ITcabenit

UPS: 30+30(kVA)rack-mounted

cooling: 25.1+25.1kW InRow air-conditione

Redundancy: N+1


VMDC-40-RRS
cabenit: 1*Integrated cabinet+ 9*ITcabenit

UPS: 40+10(kVA)modular
cooling: 21.2*(2+1)kW
Redundancy: N+1



Technical

monitoring system

modelVMDC-06-RRSVMDC-10-RRSVMDC-20-RRSVMDC-30-RRSVMDC-40-RRSODM
cabenit quanity235710LESS THAN 20
ITcabenit quanity23469LESS THAN 20
POWER DENITISY -kW/CAbinet22444less than15kW/CABINET
Redundancy styleNN+1N+1N+1N+1N/N+1/2N
depth -mm14001400140014001400customization
length -mm15002400360057006900customization
height -mm20002000200020002000less than 2500
POWER SYSTEM
UPSCAPACITY -kVA610+1020+2030+3040+10MAX90kVA
UPSrack-mountedrack-mountedrack-mountedrack-mountedmodularrack-mountedmodular
)battery configuration(1 h)12V/40Ah 16Pcs12V/65Ah 16Pcs12V/65Ah 40Pcs12V/100Ah 40Pcs12V/150Ah 40Pcscustomization
PDU32A basic 16 port32A basic 16 port32A basic 16 port32A basic 16 port32A basic 16 portcustomization
Total input power specification

63A/1P/220V

/50Hz/60Hz

63A/3P/380V

/50Hz/60Hz

80A/3P/380V

/50Hz/60Hz

125A/3P/380V

/50Hz/60Hz

160A/3P/380V

/50Hz/60Hz

customization
cooling system
cooling styleAir coolingAir coolingAir coolingAir coolingAir coolingAir cooling, water cooling and chilled water
air-conditioner configuration-kW5.67.6+7.617.6+17.625.1+25.121.2*(2+1)Per Situation
air-conditioner sytleInRowInRowInRowInRowInRowRow / rack / top mounted
Emergency ventilationAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door opening
monitoring sysem
monitoringTouch screenTouch screenTouch screenTouch screenTouch screenOptional video, access control, audible and visual / SMS alarm, centralized monitoring, etc
Temperature and humidityTemperature and humidityTemperature and humidityTemperature and humidityTemperature and humidity
UPS managementUPS managementUPS managementUPS managementUPS management
air-conditioner managementair-conditioner managementair-conditioner managementair-conditioner managementair-conditioner management
smoke detectionsmoke detectionsmoke detectionsmoke detectionsmoke detection
water leakagewater leakagewater leakagewater leakagewater leakage漏水
Door opening statusDoor opening statusDoor opening statusDoor opening statusDoor opening status

The single row scheme of micro module data center fully considers the standardized design, energy saving and capacity expansion compatibility, and adopts standardized power supply, refrigeration and cabinet units to help it experts seamlessly plan, expand and manage these key infrastructure of data center for the future.


China Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility factory
Send your message to this supplier
 
*From:
*To: Shenzhen Liruisi Electronics Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Find Similar Products By Category:
Inquiry Cart 0