| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Diabetes Glucose Meter | 
|---|---|
| Brand Name: | sinocare | 
| Model Number: | safe AQ smart | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 3000 | 
| Delivery Time: | 30 working days | 
| Price: | USD | 
| Testing: | FAD-GDH System | 
| Blood sample: | Fresh capillary whole blood, Venous whole blood | 
| Calibration sample: | Venous plasma | 
| Test range: | 20-600mg/dL(1.1-33.3mmol/L) | 
| Fast Test time: | 5s | 
| Tiny Blood volume: | 0.6ul sample size | 
| HCT: | 30-60% | 
| Expiry date: | 10 test results | 
| Battery life: | Up to 1000 tests | 
| Company Info. | 
| Changsha Sinocare Inc | 
| View Contact Details | 
| Product List | 
ISO 15197 proved Diabetes Glucose
Meter with test range 1.11-33.3
FAD-GDH System
Specification
| Blood sample: | fresh capillary whole blood, venous whole blood | 
| Calibration sample: | venous plasma | 
| Test range: | 20-600mg/dL(1.1-33.3mmol/L) | 
| Test time: | 5s | 
| Blood volume: | 0.6ul | 
| HCT: | 30-60% | 
| Expiry date: | 24 months | 
| Memory: | 10 test results | 
| Battery lifetime: | above 1000 times | 
Safe AQ blood glucose monitoring system is easy to operate, convenient and speedy. This meter use 3A batteries, it can be used about 1000 times. It can be applied to medical organizations and patients with diabetes mellitus.
First step: prepare the components you will use
Safe AQ Smart blood glucose monitoring system is easy to operate,
convenient and speedy. This meter use 3A batteries, it can be used
about 1000 times. It can be applied to medical organizations and
patients with diabetes mellitus.
Remove a new test strip within the valid expiration from vial.
After taking the strip, immediately cover the vial. To avoid losing
efficiency. Insert test strip into the strip slot, the test strip
is suggested to use up within 3 minutes.
Write the discard date (6 months after first opening the vial) on
the vial label when you first open it. Discard the remaining test
strips after the discard date.
Test Strips are for single use only. Never reuse a test strip that
has had blood applied to it.





The business of Sinocare focuses on monitoring and testing of diabetes related indicators. Through the construction of bio sensing technology platform, accelerate the POCT products R & D and industrialization based on biosensor, combining the rapid development of information technology and networking technology with POCT products, continue to provide tools of detection for patients, also provide the data analysis and expert services, to realize the evaluation of disease status, and put forward the intervention measures according to the evaluation results, the formation a “detection- evaluation – intervention“ disease management system.
|   | 
 Accuracy Result Diabetes Glucose Meter Venous Plasma Calibration Sample CE Certificated
                                                                                    
                        
                        
                        
                                                            Accuracy Result Diabetes Glucose Meter Venous Plasma Calibration Sample CE Certificated
                                                    
                        
                     Tiny Blood Simple Blood Sugar Checker , Blood Glucose Monitoring Machine Wild Htc Range
                                                                                    
                        
                        
                        
                                                            Tiny Blood Simple Blood Sugar Checker , Blood Glucose Monitoring Machine Wild Htc Range
                                                    
                        
                     ISO 15197 Proved Diabetes Glucose Meter Check Blood Sugar In Accuracy Result
                                                                                    
                        
                        
                        
                                                            ISO 15197 Proved Diabetes Glucose Meter Check Blood Sugar In Accuracy Result
                                                    
                        
                     ISO 15197 proved Diabetes Glucose Meter with test range 1.11-33.3
                                                                                    
                        
                        
                        
                                                            ISO 15197 proved Diabetes Glucose Meter with test range 1.11-33.3
                                                    
                        
                     CE Blood Sugar Checking Machine , Diabetes Monitoring Devices Support Alternate Site Testing
                                                                                    
                        
                        
                        
                                                            CE Blood Sugar Checking Machine , Diabetes Monitoring Devices Support Alternate Site Testing
                                                    
                        
                     SAFE-ACCU2 Blood Glucose Monitor , Diabetes Check Machine Concave Nib 2 OEM For Pharmacy
                                                                                    
                        
                        
                        
                                                            SAFE-ACCU2 Blood Glucose Monitor , Diabetes Check Machine Concave Nib 2 OEM For Pharmacy
                                                    
                        
                     FAD-GDH Enzyme Diabetes Glucose Meter 5s Test Time With Tiny Blood Simple
                                                                                    
                        
                        
                        
                                                            FAD-GDH Enzyme Diabetes Glucose Meter 5s Test Time With Tiny Blood Simple
                                                    
                        
                     FAD-GDH Blood Glucose Meter with Wild Htc Range ,Blood Sugar Monitoring Device with Capacity for 200 results Momery
                                                                                    
                        
                        
                        
                                                            FAD-GDH Blood Glucose Meter with Wild Htc Range ,Blood Sugar Monitoring Device with Capacity for 200 results Momery
                                                    
                        
                     Life Time Warranty Diabetes Glucose Meter With 7/14/28/60/90 Testing Result Average
                                                                                    
                        
                        
                        
                                                            Life Time Warranty Diabetes Glucose Meter With 7/14/28/60/90 Testing Result Average
                                                    
                        
                     No Coding Diabetes Blood Sugar Test Machine In Accuracy Result MOQ 3000
                                                                                    
                        
                        
                        
                                                            No Coding Diabetes Blood Sugar Test Machine In Accuracy Result MOQ 3000