| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | CT PT Test Equipment | 
|---|---|
| Brand Name: | HNMC | 
| Model Number: | HES-10 | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Negotiable | 
| Payment Terms: | T/T, L/C | 
| Supply Ability: | 10 set per month | 
| Delivery Time: | 30-45 days | 
| Packaging Details: | Wooden Package | 
| Class: | 0.05 | 
| Current Range: | up to 3150A, or more (optional) | 
| Voltage Range: | up to 35KV | 
| Operation mode: | Automatically by PC software | 
| Operating Range: | 1%-120% | 
| Rated Frequency: | 50/60 HZ | 
| Test bench rated capacity: | 10KVA | 
| Standard CT accuracy: | 0.05% or better | 
0.05% Standard Bench Type CT PT Test Equipment Test Bench HES-10
System Configuration:
1) HES-10 CT&PT Test Bench
2) HES-1C Digital Transformer Tester
3) FY49 Current Transformer Burden (5A/1A optional)
4) HLS-30G2 Standard Current Transformer ( with Current Source)
5) FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirements are available)
6) HJS-35G2 Standard Voltage Transformer ( with Voltage Source)
7) Current Transformer Primary Testing Cable
8) CT & PT Secondary Testing Cable
9) PC Test software
Main Function
Ratio error and phase angle error test of CT & PT
Technical Parameter & Features
HES-10 CT&PT Test Bench
| Input Voltage | AC 220+/-10% 50HZ, Single Phase | 
| Output voltage | AC 0-250V | 
| Rated Capacity | 10KVA | 
| Adjustment method | Manual, coarse & fine adjustment | 
| “Open-circuit demagnetization”, “Closed-circuit demagnetization”, “Error measurement” | |
| Over current protection | |
| Equipment Can be installation and placed: FY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc | |
HES-1C Digital Transformer Tester
| Rated current &voltage | 5A, 1A, 110V, 110/√3V, 100/√3V, 100/3V etc | 
| Measuring Range | |
| Ratio error | ±0.0001% ~ ±19.99%(three positions: 0.1999%, 1.999%, 19.99%). Minimum resolution:0.0001%. | 
| Phase error | ±0.01' ~ ±900'(three positions: 9.00',90.0',900'). Minimum resolution: 0.01' | 
| Impedance | 0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω | 
| Admittance | 0.001 ms ~ 19.99ms. Minimum resolution:0.001 ms | 
| Power consumption | < 20VA | 
| Rated frequency | 50 or 60HZ | 
HLS-30G2 Standard Current Transformer with current generator
| Rated Primary Current (A) | 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 160, 200, 250,300, 315, 400, 500, 600, 630, 750, 800, 1000, 1200, 1250, 1500, 1600, 2000, 2500, 3000, 3150....or More (optional) | 
| Rated Secondary Current | 5A, 1A | 
| Accuracy class | 0.05% or higher | 
| Rated secondary load | 0.2 ohm | 
| Frequency | 50HZ | 
| Operating Range | 1% - 120% | 
| Current source Capacity | 10kVA or more | 
FY49 current transformer burden
| Rated Current | 5A or 1A (optional) | 
| Operating Range | 1%--120% | 
| Rated load (VA) | CosФ = 0.8: 2.5, 3.75, 5, 6.25, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60 VA or more options CosФ = 1.0: 2.5, 3.75, 5, 6.25, 7.5, 10 VA or more options | 
| Rate Frequency | 50Hz | 
| Accuracy Class | ±3% | 
FY95 Voltage transformer burden
| Rated voltage | 100V, 100/√3V or more options | 
| Operation Range | 20%--120% | 
| Rated load | 1.25VA, 2.5VA, 5VA, 10VA,20VA, 40VA, 80VA (Total load:158.75 VA) or more option | 
| Fundamental error | ±3% | 
| Power factor | COSФ=0.8 | 
| Rated Frequency | 50Hz | 
HJS-35G3 Standard Voltage Transformer with Voltage Generator
| Rated primary voltage | 6kV,10kV,15kV,22kV,35kV or more option | 
| Rated secondary voltage | 100V,100/√3V,110V,110/√3V, or more option | 
| Accuracy class | 0.05% or higher accuracy class | 
| Secondary capacity | 0.5VA or more option | 
| Power factor | cosΦ=1.0 | 
| Power frequency | 50HZ | 
| Range of operating voltage | 20%--120% | 
| Current transformer primary test cable | 2000A x 3m x 1set,1000A x 5m x 1set 500A x 1.5m x 2set,250A x 1.5m x 2set,100A x 1.5m x 2set | 
| CT PT secondary test cable | Provided | 
|   | 
 CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System
                                                                                    
                        
                        
                        
                                                            CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System
                                                    
                        
                     0.01S Class Standard 5000A 38.5KV CT PT Test Equipment System
                                                                                    
                        
                        
                        
                                                            0.01S Class Standard 5000A 38.5KV CT PT Test Equipment System
                                                    
                        
                     0.02S Class CT PT Testing Equipment , 3200A Current Transformer Testing Equipment
                                                                                    
                        
                        
                        
                                                            0.02S Class CT PT Testing Equipment , 3200A Current Transformer Testing Equipment
                                                    
                        
                     0.005 Class CT PT Test Equipment Integrated With Source
                                                                                    
                        
                        
                        
                                                            0.005 Class CT PT Test Equipment Integrated With Source
                                                    
                        
                     CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                                                    
                        
                        
                        
                                                            CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                    
                        
                     Cabinet Type CT PT Test Equipment System Error Measurement
                                                                                    
                        
                        
                        
                                                            Cabinet Type CT PT Test Equipment System Error Measurement
                                                    
                        
                     0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                                                    
                        
                        
                        
                                                            0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                    
                        
                     0.02 Class  CT PT Test Equipment , Low Current CT Test Kit
                                                                                    
                        
                        
                        
                                                            0.02 Class  CT PT Test Equipment , Low Current CT Test Kit
                                                    
                        
                     4000A Current Transformer Tester In Magnetic Environment
                                                                                    
                        
                        
                        
                                                            4000A Current Transformer Tester In Magnetic Environment
                                                    
                        
                     0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                                                    
                        
                        
                        
                                                            0.05% CT PT Test Equipment Phase Angle Error Measurement