Product Name: Slow Blow Glass Tube Fuse 1A 2A 3.15A 250V
Blow Type: Slow blow
Size: 3.6x10mm
Ampere range: 250mA ~ 24A
Voltage: 125V/250V
Breaking capacity: 35A or 10xIn whichever is greater
Fuse alloy: Alloy
Tube: Glass
Cap: Nickel-plated copper
HS Code: 8536101090
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Alloy 250V Surface Mount Fuses


3.6x10mm Axial Leaded Slow Blow Glass Tube Fuse 1A 2A 3.15A 250V 5x20mm 6x30mm


Description Of The 3.6x10mm Axial Leaded Slow Blow Glass Tube Fuse


3.6x10mm glass fuse is one of most popular fuse to provide overcurrent protection in typical application such as power supply and LED lighting since it is cheap but it is should formed to vertical mounting & add heat shrinkable tube in power adaptor because it is spacing limiting. It can be 125V or 250V and current can be 160mA to 24A , slow blow type can withstand surge current maybe cause when start up.


Application Of The 3.6x10mm Axial Leaded Slow Blow Glass Tube Fuse


- Digital Consumer Electronics

- Power supplies

- LED Lighting


Operating Characteristics


Load capacity:When the fuse loads through 100% of rated current, should blow within 4 hours.

Breaking Capacity: 50A at 125V/250V AC.


% of Ampere Rating(In)

Blowing Time

100% * In4 hours Min
200% * In60 sec Max

Dimension Of The 3.6x10mm Axial Leaded Slow Blow Glass Tube Fuse


NO.

Part Name

Material

1

Cap

Nickel Plated Brass

2

Body

Glass Tube

3

Fuse element

Alloy

4

Lead wire

Tin Plated Copper


Specifications Of The 3.6x10mm Axial Leaded Slow Blow Glass Tube Fuse


Part

No.

Ampere

Rating

Voltage

Rating

Breaking

Capacity

I2TMelting

Integral(A2.S)

Agency Approvals

ULCUL

PSE

STP0160A/B160mA250V/125V50A@125V/250VAC0.0042
STP0200A/B200mA250V/125V50A@125V/250VAC0.0065
STP0250A/B250mA250V/125V50A@125V/250VAC0.010
STP0300A/B300mA250V/125V50A@125V/250VAC0.018
STP0315A/B315mA250V/125V50A@125V/250VAC0.020
STP0350A/B350mA250V/125V50A@125V/250VAC0.025
STP0400A/B400mA250V/125V50A@125V/250VAC0.035
STP0500A/B500mA250V/125V50A@125V/250VAC0.060
STP0630A/B630mA250V/125V50A@125V/250VAC0.150
STP0750A/B750mA250V/125V50A@125V/250VAC0.350
STP0800A/B800mA250V/125V50A@125V/250VAC0.5
STP1100A/B1A250V/125V50A@125V/250VAC0.6
STP1125A/B1.25A250V/125V50A@125V/250VAC1.2
STP1150A/B1.5A250V/125V50A@125V/250VAC1.6
STP1160A/B1.6A250V/125V50A@125V/250VAC1.8
STP1200A/B2A250V/125V50A@125V/250VAC2.4
STP1250A/B2.5A250V/125V50A@125V/250VAC3.2
STP1300A/B3A250V/125V50A@125V/250VAC6.0
STP1315A/B3.15A250V/125V50A@125V/250VAC7.0
STP1350A/B3.5A250V/125V50A@125V/250VAC7.5
STP1400A/B4A250V/125V50A@125V/250VAC8.0
STP1500A/B5A250V/125V50A@125V/250VAC15
STP1600A/B6A250V/125V50A@125V/250VAC24
STP1630A/B6.3A250V/125V50A@125V/250VAC28
STP1700A/B7A250V/125V50A@125V/250VAC36
STP1800A/B8A250V/125V50A@125V/250VAC-
STP2100A/B10A250V/125V50A@125V/250VAC-
STP2120A/B12A250V/125V50A@125V/250VAC-
STP2150A/B15A250V/125V50A@125V/250VAC-
STP2160A/B16A250V/125V50A@125V/250VAC-

Tubular Fuse Family


Glass Tube Fuse
SeriesSizeVoltageCurrent rangeBlow TypeCertificates
STP3.6x10mm125V/250V250mA ~ 24ASlow BlowUL/CUL
SFP3.6x10mm125V/250V250mA ~ 24AFast BlowUL/CUL
TBP3.6x10mm125V/250V250mA ~ 24ASlow BlowUL/CUL/CCC/VDE
FBP3.6x10mm125V/250V250mA ~ 24AFast BlowUL/CUL/CCC/VDE
STC5x20mm125V/250V250mA ~ 24ASlow BlowUL/CUL
SFC5x20mm125V/250V250mA ~ 24AFast ActingUL/CUL
TBC5x20mm125V/250V250mA ~ 24ASlow BlowUL/CUL/CCC/VDE/PSE/KTL
FBC5x20mm125V/250V250mA ~ 24AFast ActingUL/CUL/CCC/VDE/PSE/KTL
MTC6x30mm125V/250V100mA ~ 50ASlow BlowUL/CUL
MFC6x30mm125V/250V100mA ~ 50AFast ActingUL/CUL
Ceramic Tube Fuse
PTU3.6x10mm125V/250V160mA ~ 6ASlow BlowUL/CUL
PFU3.6x10mm125V/250V160mA ~ 6AFast BlowUL/CUL
HTP3.6x10mm125V/250V6.3A ~ 15ASlow BlowUL/CUL
HFP3.6x10mm125V/250V6.3A ~ 15ASlow BlowUL/CUL
TBP3.6x10mm125V/250V250mA ~ 24ASlow BlowUL/CUL/CCC/VDE
FBP3.6x10mm125V/250V250mA ~ 24AFast BlowUL/CUL/CCC/VDE
BTC5x20mm125V/250V200mA ~ 10ASlow BlowUL/CUL
BFC5x20mm125V/250V200mA ~ 10AFast ActingUL/CUL
BMT6x30mm250V100mA ~ 50ATime LagUL/CUL
BMF6x30mm250V100mA ~ 50AFast ActingUL/CUL
5.250.T5x20mm250V0.1A ~ 30ATime LagUL/CUL
5.250.F5x20mm250V0.1A ~ 30AFast ActingUL/CUL
6.250.T6x30mm250V100mA ~ 50ATime LagUL/CUL
6.250.F6x30mm250V100mA ~ 50AFast ActingUL/CUL


Average Time Current Curves



Anatomy of Fuses


Electrical appliances and equipment are protected by the tiny fuses that are installed in their wiring or housing. They break the electrical circuit should something nefarious happen to the current, such as being overloaded due to a power surge during a severe storm, or if a circuit decides to short. The tiny fuse prevents the problem at the source from traveling to an expensive appliance or beloved décor item and destroying its fine electrical systems. It also keeps the item from making a bigger problem, such as fire or water damage if a machine full of wet items fails before the spin cycle. Fuses come in all shapes and sizes. They are also made of many different types of material to ensure they can function properly under various conditions fuses might confront during its relatively short duration in the appliance or fixture. The two main materials that are used to manufacture well-built fuses are glass and ceramic. The types of fuses include long-time-lag or super-time-lag (TT), fast-acting fuses (FF), quick-blow fuses (F) and slow-blow or time-lag fuses (T).


Fuses at Work


A current can become corrupted or overloaded due to accidental damage from pets or being moved, general deterioration, excessive overloading of the electrical system or exposure to the elements. If you have a fixture outdoors, the fuse may need replacing more often due to the harsh environment the tiny workhorse endures on a daily basis. Generally, a current overload happens from a temporary surge from a motor starting up or too many items on the same line. The fuse holds back the overcurrent from reaching the appliance. The body – or barrel – has a plated copper or brass tip – or terminal – at each end of the fuse. The element connects the terminals. The element is made of zinc, copper, aluminum or silver.


China Alloy 250V Surface Mount Fuses factory
Send your message to this supplier
 
*From:
*To: Dongguan Ampfort Electronics Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0