| Brand Name: | Shenglin | 
| Model Number: | SHSL-D3 Series | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | 805~40010 USD/Unit | 
| Payment Terms: | T/T, Western Union, L/C | 
| Supply Ability: | 100 units per month | 
| Delivery Time: | 30~35days | 
| Packaging Details: | For sample and less than container order: plywood case, dry cooler For container order: pallet and wrapping film | 
| Tube material: | Usually is Copper | 
| Fin material: | Usually is aluminum | 
| Frame material: | Galvanized steel plate | 
| Power supply: | 380~400V/3P/50Hz or 380~400V/3P/60Hz | 
| Options A: | Sprinkler System is available | 
| Options B: | Wet curtain system is available | 
| Fan brand: | Chinese brand | 
| Application: | Bitcoin Cooling System | 
Wet-Dry Coolers With Direct Water Spray System For Bitcoin Two-phase Liquid Cooling System
Two-phase liquid cooling:
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

Features
1. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
2. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
3. Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany.
4. Fan: only choose low specific energy consumption fans.
5. Fan nozzle designs for maximum air flow and air throw.
6. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
7. Motor: protection class IP 54 and insulation class F.
8. Air separator for each fan.
9. We facilitate you to have a long lasting and low maintainance operation.
10. Durable material and rigid enclosure with hard gloss powder coated finish.
11. Protective enclosure for both manifolds and U-bends.
12. Unit design for outdoor installation. 100% leakage tested at 31bar.
Options
A. Coil design refrigerant: water, oil, glycol.
B. Multiple circuits.
C. Sub-cooling circuits.
D. Stainless steel or aluminum casing.
E. Coated aluminum or copper fins.
F. Explosion proof motor.
G. Customized fin spacing.
Technical parameter
Dry cooler D3 series parameter (fin space 2.1mm)
| Type D3- | 042-1X800 | 046-1X800 | 051-1X800 | 087-2X800 | 094-2X800 | 103-2X800 | 125-3X800 | 146-3X800 | D53-3X800 | 175-4X800 | 188-4X800 | ||||
| Capacity (KW) | Water | 35℃ outdoor temp. | Inlet | 45℃ | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | 
| outlet | 40℃ | ||||||||||||||
| 20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||
| outlet | 40℃ | ||||||||||||||
| Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||
| Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||
| Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||
| Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||
| A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||
| Fan | No X φ | 1x1 x800 | 1x1 x800 | 1x1 x800 | 1x2 x800 | 1x2 x800 | 1x2 x800 | 1x3 x800 | 1x3 x800 | 1x3 x800 | 2x2 x800 | 2x2 x800 | |||
| Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||
| 10m | |||||||||||||||
| Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||
| W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||
| H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||
| A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||
| B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||
| B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||
| B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||
| B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||
| X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||
| Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 | |||
We can OEM design dry coolers.
Tell us the datas as following:
A. Required BC888·s inlet temperature?
B. Required BC888·s outlet temperature?
C. BC888 flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Packing:
|  |  | 
|  |  | 
|   | 
 Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers
                                                                                        
                                                        
                        
                        
                        
                                                            Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers
                                                    
                        
                     Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System
                                                                                        
                                                        
                        
                        
                        
                                                            Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System
                                                    
                        
                     Ziehl-Abegg Fan Dry Fluid Cooler Table Type Structure For Immersion Cooling System
                                                                                        
                                                        
                        
                        
                        
                                                            Ziehl-Abegg Fan Dry Fluid Cooler Table Type Structure For Immersion Cooling System
                                                    
                        
                     Immersion Liquid Cooling Dry Cooler
                                                                                        
                                                        
                        
                        
                        
                                                            Immersion Liquid Cooling Dry Cooler
                                                    
                        
                     Crypto Cooling Single Phase Immersion Cooling System Dry Coolers
                                                                                        
                                                        
                        
                        
                        
                                                            Crypto Cooling Single Phase Immersion Cooling System Dry Coolers
                                                    
                        
                     Bitcoin Or Litecoin Mining Cooling System Radiators
                                                                                        
                                                        
                        
                        
                        
                                                            Bitcoin Or Litecoin Mining Cooling System Radiators
                                                    
                        
                     Submerging Bitcoin Miners Liquid Immersion Cooling Dry Coolers
                                                                                        
                                                        
                        
                        
                        
                                                            Submerging Bitcoin Miners Liquid Immersion Cooling Dry Coolers
                                                    
                        
                     IT Devices Liquid Immersion Submerging Bitcoin Cooling System
                                                                                        
                                                        
                        
                        
                        
                                                            IT Devices Liquid Immersion Submerging Bitcoin Cooling System
                                                    
                        
                     Pre Cooling Adiabatic Dry Cooler Immersion Cryptocurrency Miner Cooling System
                                                                                        
                                                        
                        
                        
                        
                                                            Pre Cooling Adiabatic Dry Cooler Immersion Cryptocurrency Miner Cooling System
                                                    
                        
                     TurnKey Solution Hydrophilic Fin Copper Tubes Air Dry Crypto Mining Cooler
                                                                                        
                                                        
                        
                        
                        
                                                            TurnKey Solution Hydrophilic Fin Copper Tubes Air Dry Crypto Mining Cooler