| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Digital Flow Meter | 
|---|---|
| Place of Origin: | Anhui, China | 
| Brand Name: | WNK | 
| Model Number: | WLD | 
| Packaging Details: | One set in per carton, standard packing | 
| Supply Ability: | 1000 Piece/Pieces per Month | 
| Price: | $480.00/Pieces >=1 Pieces | 
| Type: | Variable Area Water Flowmeters | 
| Maximum flow rate: | 15m/s | 
| Fluid conductivity: | ≥5μs/cm | 
| Ambient temperature: | -25~60℃,-10~60℃ | 
| Liner material: | PTFE/PVF/F46/Neoprene/PUR | 
| Fluid maximum temperature: | 100℃,150℃ | 
| Signal electrode form: | DN15-DN2600,DN300-DN1600 | 
| Electrode material: | SS316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum Iridium | 
| Connecting flange material: | Carbon Steel | 
| Grounding flange material: | SST 1Cr18Ni9Ti | 
| Protection: | IP65/68 | 
| Port: | Shanghai | 
| Company Info. | 
| Hefei WNK Smart Technology Co.,Ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
| WLD electromagnetic flowmeter is manufactured with the latest
technology with the following defects: | ||||||||
| - Measurements are not affected by changes in fluid density,
viscosity, temperature, pressure and conductivity; | ||||||||
| - Unobstructed flow components in the measuring tube, no pressure
loss, low requirements for straight pipe sections; | ||||||||
| - Series nominal diameter DN3-DN3000. There are many options for
sensor liner and electrode materials; | ||||||||
| - The converter adopts novel excitation mode, low power
consumption, stable zero point and high precision. The flow range
can be1500:1 | ||||||||
| - The converter can be integrated or separated from the sensor; | ||||||||
| - The converter adopts 16-bit high-performance microprocessor,
2X16LCD display, convenient parameter setting and reliable
programming; | ||||||||
| - Explosion-proof instruments can be used in corresponding
explosion-proof places; | ||||||||
| - The converter uses surface mount technology (SMT) with self-test
and self-diagnosis functions; | ||||||||
| Maximum Flow Rate | 15m/s | ||||||
| Nominal Pressure | DN15~DN150 | 4.0Mpa | |||||
| DN15~DN600 | 1.6Mpa | ||||||
| DN200~DN1000 | 1.0Mpa | ||||||
| DN700~DN3000 | 0.6Mpa | ||||||
| Ambient Temperature | Sensor | -25~60℃ | |||||
| Coverter | -10~60℃ | ||||||
| Liner material and fluid maximum temperature | Liner material | Separate type | Integrated type | ||||
| PTFE | 100℃;150℃ | 70℃ | |||||
| PVF | 100℃;150℃ | 70℃ | |||||
| FEP | 100℃;150℃ | 70℃ | |||||
| Neoprene | 80℃;120℃ | 70℃ | |||||
| PUR | 80℃ | 70℃ | |||||
| Signal electrode form | Fixed (DN15~DN2600) Scraper(DN300-DN1600) | ||||||
| Electrode material | SS316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum Iridium | ||||||
| Connecting flange Material | Carbon Steel | ||||||
| Grounding flange material | SST 1Cr18Ni9Ti | ||||||
| Imported prodective flange material | DN15~DN600 | SST 1Cr18Ni9Ti | |||||
| DN700-DN3000 | Carbon Steel | ||||||
| Protection | DN15-DN150 Separate rubber and polyurethane liner sensors | IP65.68(Special customize) | |||||
| DN200-DN2600 Separate rubber and polyurethane liner sensors | IP68 under water 10 meters | ||||||
| Other sensor converter | IP65 | ||||||
| Spacing(separate type ) | The Spacing Less than or equal to 100 meters or need Special
customize | ||||||














|   | 
 WNK 1.6Mpa Digital Flow Meter , Insert Steam Flow Sensor
                                                                                    
                        
                        
                        
                                                            WNK 1.6Mpa Digital Flow Meter , Insert Steam Flow Sensor
                                                    
                        
                     IP65 IP68 Turbine Type Flow Meter SST 1Cr18Ni9Ti Grounding flange material
                                                                                    
                        
                        
                        
                                                            IP65 IP68 Turbine Type Flow Meter SST 1Cr18Ni9Ti Grounding flange material
                                                    
                        
                     10m/s Digital Flow Meter , WNK HART Hydraulic Oil Flow Meter
                                                                                    
                        
                        
                        
                                                            10m/s Digital Flow Meter , WNK HART Hydraulic Oil Flow Meter
                                                    
                        
                     Electromagnetic Digital Flow Meter , Variable Area 50mm Water Flow Meter
                                                                                    
                        
                        
                        
                                                            Electromagnetic Digital Flow Meter , Variable Area 50mm Water Flow Meter
                                                    
                        
                     OEM Electromagnetic Flow Transmitter , RS485 Gas Flow Meter
                                                                                    
                        
                        
                        
                                                            OEM Electromagnetic Flow Transmitter , RS485 Gas Flow Meter
                                                    
                        
                     OEM ODM 15m/s Digital Flow Meter For Sewage Water SST 1Cr18Ni9Ti flange
                                                                                    
                        
                        
                        
                                                            OEM ODM 15m/s Digital Flow Meter For Sewage Water SST 1Cr18Ni9Ti flange
                                                    
                        
                     WLC Insertion Electromagnetic Flow Meter Stainless steel Sensor material
                                                                                    
                        
                        
                        
                                                            WLC Insertion Electromagnetic Flow Meter Stainless steel Sensor material
                                                    
                        
                     HART Protocol Sewage Water Flow Meter With Digital Display SS316L Electrode
                                                                                    
                        
                        
                        
                                                            HART Protocol Sewage Water Flow Meter With Digital Display SS316L Electrode
                                                    
                        
                     insert type Digital Flow Meter , RS485 Compressed Air Meter
                                                                                    
                        
                        
                        
                                                            insert type Digital Flow Meter , RS485 Compressed Air Meter
                                                    
                        
                     ODM Hydrogen Gas Flow Meter SST Grounding flange  with 2X16 LCD display
                                                                                    
                        
                        
                        
                                                            ODM Hydrogen Gas Flow Meter SST Grounding flange  with 2X16 LCD display