| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Laboratory Test Equipment |
|---|---|
| Brand Name: | AI |
| Model Number: | 4530F |
| Certification: | ISO9001 |
| Place of Origin: | China |
| MOQ: | 1 set Atomic Absorption Spectrophotometer |
| Price: | Negotiable |
| Payment Terms: | Western Union, T/T, L/C |
| Supply Ability: | 100 sets each month |
| Delivery Time: | 30 days |
| Packaging Details: | Atomic Absorption Spectrophotometer packed in veneer case. |
| Function: | metal element analysis |
| Lamp turrents: | 8 |
| Control method: | Computer control |
| Wavelength range: | 190 – 900nm |
| Spectral bandwidth: | 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
| Grating: | 1800 lines/mm |
| Inflamer: | All-metal titanium burner |
| Atomizer: | Effective glass atomizer |
| Size: | 700mm×550mm×450mm |
| Weight: | 75kg |
| Company Info. |
| Advanced Instruments Co.,Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
Flame Atomic Absorption Spectrophotometer
Features:
Specifications of 4530F Atomic Absorption Spectrophotometer :
| Wavelength range | 190 – 900nm |
| Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
| Accuracy of the wavelength | ±0.15nm |
| Receptivity of the wavelength | ≤0.04nm |
| Base line stability | ≤0.002A/30min (Cu) |
| Characteristic viscosity | 0.02μg/ml/1% (Cu) |
| Checking limit | 0.004μg/ml (Cu) |
| Preciseness | 0.5% |
| Grating | 1800 lines/mm |
| Inflamer | All-metal titanium burner |
| Atomizer | Effective glass atomizer |
| Lamp stand | Eight lamps |
| D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
| Size and weight | 700mm×550mm×450mm 75Kg |
| Power source | 220V±22V AC |
Flame System:
| Acetylene air burner | 100mm |
| Nitrous oxide acetylene flame head | 50mm |
| Ignition dynamic baseline drift | ≤0.006A/30min |
| (Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
| Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
| Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
Optional Graphite Furnace:
| The highest temperature | 3000℃ |
| The largest temperature rising speed | ≥2000℃/S |
| Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
| Accuracy | Cu≤3% Cd≤3% |
| Size and weight | 550mm×450mm×300mm 65Kg |
| Safety system | Over current protection |
| Protection | Low air pressure alarm, low cooling water flow alarm |
| Power source and power | 220V±22V AC 7000W |

|