| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Din Rail Energy Meter |
|---|---|
| Brand Name: | RISESUN |
| Model Number: | RS217DR4-1 |
| Place of Origin: | China. Zhejiang |
| MOQ: | 500 pcs |
| Price: | negotiation |
| Payment Terms: | L/C, T/T,negotiation |
| Supply Ability: | 100,000 pcs per month |
| Delivery Time: | 30 work days |
| Packaging Details: | Carton |
| Name: | One Phase Din Rail Energy Meter Din Rail Mounted Power Meter DIN EN 62053 31 |
| Keyword: | power monitoring meter |
| Meter Type: | RS217DR4-1 |
| Rated voltage,extended range: | 230V,50Hz,-20%/+15% |
| Reference current Iref(Limiting current Imax): | 10(65)A/5(32)A |
| Internal consumption active power: | 0.4W |
| Ambient temperature limits: | -25℃/+55℃ |
| Interface: | potential free by opto-coupler, max.30V DC/20mA and min.5V DC. SO: pulse outputdescribed in DIN EN 62053-31, impedance 100 Ohm, pulse length 30ms,2000imp./kWh |
| Protection degree: | IP50 for mounting in distribution cabines with protection class IP51 |
| Maximum conductor cross section: | L terminals 16mm²,N and SO terminals 6mm² |
| Type examination certificate: | TCM 221/14-5207 |
| Mechanical environmental conditions: | Height:82mm,Width:18mm,Depth:58mm |
Din Rail Single Phase Meter
Features
1. Measuring function: It can measure the positive active energy, and also can measure various parameters in real time, such as voltage, current, active power.
2. Display: LCD display with 5 integrals and two decimals,i.e.99999.99kWh.
3. Installation: It is the 35mm standard of DIN-50022.
4. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Press the button.
Technical specifications
| Items | Contents |
|---|---|
| Rated voltage,extended range | 230V,50Hz,-20%/+15% |
| Reference current Iref(Limiting current Imax) | 10(65)A/5(32)A |
| Internal consumption active power | 0.4W |
| Type | RS217DR4-1 |
Inrush current according to accuracy class B | 40mA |
| Ambient temperature limits | -25℃/+55℃ |
Interface | potential free by opto-coupler, max.30V DC/20mA and min.5V DC. SO: pulse output described in DIN EN 62053-31, impedance 100 Ohm, pulse length 30ms,2000imp./kWh |
| Protection degree | IP50 for mounting in distribution cabines with protection class IP51 |
| Maximum conductor cross section | L terminals 16mm², N and SO terminals 6mm² |
| Type examination certificate | TCM 221/14-5207 |
| Mechanical environmental conditions | class M1 |
| Electromagnetic environmental conditions class | class E2 |
| Accuracy class ±1% | B |
| External Dimensions | Height:82mm, Width:18mm, Depth:58mm |
|