Product Name: Vortex Flow Meter
Pipe Size: DN150
Accuracy: ±1.0% for Liquid, ±1.5% for Gas
Ambient Temperature: -35℃~60℃(without LCD);-5℃~60℃(with LCD)
Working Pressure: 1.6MPa(standard), 2.5~4.0MPa(according to customer's requirements)
Velocity Range: 0.7~7m/s for Liquid, 7~40m/s for Gas
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

DN150 Flange Type Vortex Flow Transmitter Stainless Steel Material Simple Structure

China DN150 Flange Type Vortex Flow Meter with Stainless Steel Material

1. Introduction
LUGBML is based on Von Karman’s Vortex Principle, which adopts piezoelectric crystal as testing components. It is a new kind of stress detecting vortex flow meter. It has the advantage of wide range ratio, high accuracy, low pressure loss, good medium generality, pulse output proportional to flow, convenient to connect with computer and etc. As the detector probe of sensor and the vortex generating body are installed separately, and the high temperature resistant piezoelectric crystal doesn’t contact with medium, so the instrument is of simple structure, good generality and high stability.
LUGBML series Vortex Flow Meter sensor can be used to detect and measure the flow of all kinds of gas, liquid and steam.
LUGBML series Vortex Flow Meter can be used to match with our company’s ML6000 series Velocity Flowmeter. It can also match with a computer and sensors of temperature, pressure, or density to compose high accuracy mass flow or heat flow detecting and measuring system.

2. Features

  • The structure of Vortex Flow Meter is simple and solid, no movable parts and it is very stable.
  • Simple installation and easy maintenance.
  • Wide measuring range, the ratio is up to 10:1.
  • The volume of fluid is compensated according to requirements, and the instrument coefficient does not need to be re-calibrated after the replacement of the accessories.


3. Specifications

Measuring MediumSteam, Gas, Liquid(avoid multiple direction fluid)
Accuracy±1.0% for Liquid, ±1.5% for Gas
Repeatability0.33% for Liquid, 0.5% for Gas
Velocity Range0.7~7m/s for Liquid, 7~40m/s for Gas
Working Pressure1.6MPa(standard), 2.5~4.0MPa(according to customer's requirements)
Fluid Temperature-40~250℃(standard temperature); 100~350℃(high temperature)
Body Material304 SS for standard, 316 SS for option
OutputPulse(three-wired, low voltage≤1V and high voltage≥4V),4-20mA, RS485
Power Supply24VDC/12VDC,3.6V Lithium Battery
Ambient Temperature-35℃~60℃(without LCD);-5℃~60℃(with LCD)
Relative Humidity5~95%
Protection ClassIP65
Electrical connectionM20*1.5



4. Configuration

LUGBML Series Vortex Flow Meter Configuration
ModelLUGBML
Sensor InstallationDClamp Type Sensor
FFlange Type Sensor
CInsertion Type Sensor
MediumLLiquid
GGas
SSteam
Pipe Material2525mm
......
300300mm
Power SupplyADuplicate Supply(24VDC/12VDC+3.6V Lithium Battery)
B3.6V Lithium Battery
C24VDC/12VDC
DisplayDWith Digital Display
PWithout Digital Display
OutputNNone
PPulse
A4-20mA
RRS485
HHart
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers
Sensor MaterialA304 SS (Standard)
B316 SS
OOthers
Medium TemperatureE40~250℃
H100~350℃
Rated Pressure161.6MPa
252.5MPa
404.0MPa
OOthers
Protection Class0IP65
Explosion Proof0None
EXExplosive Proof


5. Design & Installation
It is important to install meter,if not installed well, then would affect precision, use-life and damage.
1. To avoid strong current, high frequency and powerful switch set, power supply of meter shall be avoided to near by these equipments.
2. To avoid high-Temp & radiation source. if have to install it, need heat insulation & ventilated measure.
3. To avoid high-Temp & enchant gas, if have to install it, need ventilated measure.
4. Vortex flow meter shall be avoided to install on shaking part of pipeline. If have to install on it,shall add clamp device and vibration pad which located on 2D to enhance shake proof . meter has better to installed indoors, pay attention to waterproof when installing meter outdoors,special notice the joint, make cable conductor to U shape to avoid water get into the amplifier body Around installing place shall save enough space,so that install connection line and maintenance routine.