| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Energy Efficiency Lab | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SN335 | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Tailored | 
| Payment Terms: | T/T | 
| Supply Ability: | 1 Set Per Month | 
| Delivery Time: | 2 Months | 
| Packaging Details: | Plywood | 
| UUT: | Ceiling fans | 
| Control: | Computer | 
| Lab Inner Dimensions: | L 4.5m * W 4.5m * H 3m | 
| Lab Outer Dimensions: | L 6m * W 5m * H 5m | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
IEC 60879 Energy Efficiency Computer Controlled Test Lab for Electric Circulating Fans
Overview:
This testing system is made according to the laboratory requirements stipulated in IEC 60879 1986 Corr 1992 Performance and Construction of Electric Circulating Fans and Regulators, and will meet the testing requirements of ceiling fan.
The energy efficiency testing system is controlled by computers, the system can display the air volume value of each testing point and the average air volume and point air volume of each circle, and can automatically generate and print testing results and the process curve. The minimum computer configuration shall include 250G hard disk, 17-inch LCD and 2G memory.
The system will conduct operations strictly in accordance with IEC standards, that is to say it will collect the accumulative pulse number of air volume within two minutes for achieving average air volume.
Standards:
Can be designed according to the following standards:
► IEC 60879 1986 Corr 1992 or latest version
► Other standards
Types of UUT :
Ceiling Fans
Technical Conditions:
1. This system meets requirements of air volume measurement stipulated in IEC 60879. It has many characteristics, such as reasonable in design, high in automation level, convenient in operation and wear resistant, and has bearing and anti-vibration ability.
2. Testing range: ceiling fan.
3. Controlled by computers, the system can display the air volume value of each testing point (including position, delay time 1min and testing time 2min) every three minutes generally and the average air volume and point air volume of each circle, and can automatically generate and print testing results and the process curve. The minimum computer configuration shall include 250G hard disk, 17-inch LCD and 2G memory.
4. The air speed shall be measured on the four half diagonal sections of the test panel and measured from 40mm from the center of the diagonal (on the vertical line passing through the center of the blade) and then gradually move to each side by increment of 80mm. The measurement will stop until the calculated average speed drops below 9 m/min. The average speed of any ring shall be the average of the readings on the four half diagonal sections at the average radius of the ring.
5. Fixed frame of fan and anemometer base are equipped with universal adjustable console, and the installation height will be adjusted conveniently within required range.
6. Testo435-2 type anemometer for vane, diameter of vane 100mm.
7. The system is equipped with multiple-functional electric measuring instrument that can measure voltage, current (true effective value) and power.
8. Dimension of test panel and construction (dimension of external wall and internal wall of laboratory)
Dimension of external wall of laboratory (external dimensions): L 6m * W 5m * H 5m
Dimension of Internal wall of laboratory (Internal dimensions): L 4.5m * W 4.5m * H3m
System Structure:

|   | 
 IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                                                    
                        
                        
                        
                                                            IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                    
                        
                     Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                                                    
                        
                        
                        
                                                            Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                    
                        
                     Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                    
                        
                     Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                                                    
                        
                        
                        
                                                            Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                    
                        
                     Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                    
                        
                     Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                                                        
                                                        
                        
                        
                        
                                                            Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                    
                        
                     IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                                                    
                        
                        
                        
                                                            IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                    
                        
                     Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                                                    
                        
                        
                        
                                                            Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                    
                        
                     Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                                                    
                        
                        
                        
                                                            Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                    
                        
                     10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans
                                                                                    
                        
                        
                        
                                                            10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans