Brand Name: J-ENERGIZE
Model Number: JET-ACO 380/20
Place of Origin: XIAN, CHINA
MOQ: 1 Unit
Payment Terms: L/C, T/T, Negotiable
Delivery Time: Negotiable
Packaging Details: Wooden Case
Load voltage: Three-phase AC380V, Single-phase AC220V
Load Power (3-Phase): 200KW
Display: 8-inch TFT
Voltage measurement range: AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%
Current measurement range: AC 0~400A, Resolution 0.1A, Precision 0.5%
Power measurement range: 0~200 KVA, Display Resolution: 0.1KVA, Precision: 1%
Type: Resistive load bank
Application: Generator,UPS,Battery,Power Plant,Generator Load Test
Qty of Parallel Operation: 1~99 sets
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

3 Phase Variable AC Resistive Load Bank 200KW For Generator 8 Inch TFT Display

200KW AC Variable Resistive Load Bank 3 Phase Load Bank for Generator

JET-ACO 380/20 AC Resistive Load Bank


Why a load testing?

A load testing is part of the maintenance for a generator.

There are multiple reasons generator should undergo a load bank test on an annual basis, including but not limited to the following:

  • Verifies the generator capabilities opposed to just routinely starting it up.
  • Problems discovered early can be significantly less expensive and prevents future major issues.
  • Helps to avoid wet-stacking and cleans out carbon deposits.
  • Verifies the engine cooling systems will perform while under load.
  • Provides assurance that the generator should work properly when you need it most.

What it will be tested?

  • Three-phase voltage
  • Current
  • Active power& reactive power
  • Apparent power
  • Power factor
  • Frequency
  • Running time
  • Energies of generators and UPS

Functions & Features

◆ Test three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.

◆ It has harmonic analysis of 2-50 orders of harmonic content and the total harmonic content for voltage or current.

◆ Set/adjust discharging power according to performance parameters and detection requirements

◆ Set discharging time, timing to automatic shut-off load, discharge off and alarm operator

◆ Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.

◆ Large LCD screen, friendly interface. English menu and easy operation.

◆ Parallel operation function to carry out multi sets load operation by RS 485 communication

◆ Built-in storage save 30 groups of test data, which can be viewed, deleted and export into SD card.

◆ Start/stop discharging control by Serial port, and detect data real time operation etc.; The storage data can be uploaded to PC by serial port or SD card, and the upper computer’s software can analyze data and pattern and print report etc.

◆ Overheating and over current protection function, it can turn off load, terminate discharging and alarm automatically when over temperature and over current.

◆ Set at most 5 groups power, load process automatically according to the setting power and operation time after being turned on.


Specifications


ModeJET-ACO 380/20
Load voltageThree-phase AC380V, Single-phase AC220V
Operating power

Stand-alone: Max 200KW (Three-phase 380V)

Max 66KW (Singly-phase 220V)

Cooling modeFCT (Fan control Temperature)
Communication ModeRS232, RS485 and SD card
Display mode8-inch TFT
Voltage measurement rangeAC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%
Current measurement rangeAC 0~400A, Display Resolution: 0.1A, Precision: ±0.5%
Frequency measurement range40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2%
Power measurement range0~200 KVA, Display Resolution: 0.1KVA, Precision: ±1%
Power factor measurement range0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%
Discharging Time(0~19 hours and 59 minutes) adjustable continuously
Quantity of Parallel operation1~99 sets
Recording Period6~999 Seconds
Temperature measurement range-20~100℃,Display resolution: 1℃, precision:±1℃
Insulating strength

Input≥AC1500V

Output≥AC500V

Working environment

Working Temperature: (-20~55)℃,

Storage Temperature: (-45~75)℃

Relative humidity: 90%(40±2℃)

Atmospheric pressure: (70~106) KPa

Working power supplySingle-phase AC220V±10, 50Hz
MTTF≥50000h
Dimensions(mm)1300×600×900mm
Weight150kg

Service

1. Pre-service

-- 7/24 online service for your consult.

-- Help choose right model, and a series of service, person, advise.

2. Middle service

-- Give you best offer.

-- Provide discount for qty order.

-- Do customer's request.

-- Choose payment term as you convenient.

-- Delivery promptly, and inform you in time.

-- Provide invoice value as you like to decrease your tax.

3. After sale service

-- 1-year warranty service and all life maintenance.

-- Technical engineer are available for oversea training.

-- Free change for some parts.

-- Remote control technical service.

-- Free installation DVD

-- Maintenance plan.

China 3 Phase Variable AC Resistive Load Bank 200KW For Generator 8 Inch TFT Display factory
Send your message to this supplier
 
*From:
*To: Xian Junbiao Electronics Technology Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0