| Categories | Power Distribution Terminal | 
|---|---|
| Brand Name: | Tianyihongda | 
| Model Number: | TYHD-DTU-6 | 
| Certification: | type test report | 
| Place of Origin: | Beijing,China | 
| MOQ: | 1set(3pcs) | 
| Price: | Negotiation | 
| Payment Terms: | Western Union, L/C, T/T | 
| Supply Ability: | 3000sets per week | 
| Delivery Time: | 3000 sets within 1 week | 
| Packaging Details: | 56*40*34cm,48 pcs /box ,standarad export box | 
| Protection function: | detect line fault and overload status | 
| Self-test: | high reliability circuit design and perfect diagnosis and self-recovery function. | 
| man-machine interaction: | optional function | 
| remote measurement: | With channel monitor function | 
DTU power distribution network feeder automation device with with characters of high stability and reliability
DTU power distribution network feeder automation device is used for terminal monitoring for RMU, small switching station,can connect with master station and realize the electrical signal gathering and control from multi-lines, fault detection, fault area location, isolation and non-fault area power restore to improve power supply reliability.
DTU power distribution network feeder automation device is with a hardware platform of 32 bits of microprocessor of high-performance, is with embedded real-time operation as a software development platform, also with characters of high stability and reliability , high performance,high intensity and low cost and easily installation.
The mechanical structure is double-case type,outer case is in a whole with function of anti-rain and anti-dust, inner layer adopts module mechanical case,easily installed,with clear structure,outer case is 1400mm×600mm×400mm,1000mm×600mm×350mm,750mm×600mm×300mm etc.(can be customized), the inner case adopts standard 6U mechanical case(some switching station can be directly installed inner case).the appearance design can be flexible as client’s requirement.

1.whole device power consumption
1)whole device power consumption not above 30W.
2.serial interface
1)Asynchronization RS232 interface:there are 4 pieces of general interface. One of them can be configured as RS485 interface.
3.Ethernet interface
1)10M Ethernet RJ45 interface 2 pieces(industrial grade switch interface,can constitute Ethernet bus.
4.USB interface(reserved)
1)Through USB save more data
5.Communication Protocals
1)Serial interface:CDT,IEC60870-5-101 protocals etc.
2)Ethernet interface:based TCP/IP of IEC60870-5-104 protocal etc.
Technical Parameters:
| rated data: | electrical insulation performance | 
| 
 | 
 | 
| Function: | EMC performance: | 
| 
 | 
 | 
| measurement accuracy: | ambient temperature: | 
| 
 active power, reactive power frequency:grade 1.0. | 
 | 
There is type test report for it, test items as following:
| Type Test Items | 1. appearance and structure 2.function 3. electrical device performance 4.low temperature performance 5.high temperature performance 6.alternating temperature humidity7.vibrationendurance 8.incline drop test 9. electrical device life 10. static electricity and elecro-discharge immunity test 11.radio frequency electromagnetic field radiated immunity test 12.surge impact immunity test 13. power frequency magnetic field immunity test. 14. Adjacent interference test 15.short-circuit withstand impact test 16. fire hazard test 17. power consumption test 18. protection grade test 19. gripping strength test of grip structure. | 
|   | 
 DTU Network Feeder Power Distribution Terminal Automation Device High Performance
                                                                                    
                        
                        
                        
                                                            DTU Network Feeder Power Distribution Terminal Automation Device High Performance
                                                    
                        
                     DTU Power Remote Transmission Unit , High Stability Network Termination Unit
                                                                                    
                        
                        
                        
                                                            DTU Power Remote Transmission Unit , High Stability Network Termination Unit 
                                                    
                        
                     High Frequency Power Distribution Terminal 18 Lines Remote Control Self Check
                                                                                    
                        
                        
                        
                                                            High Frequency Power Distribution Terminal 18 Lines Remote Control Self Check
                                                    
                        
                     High Speed Digital Signal Processing System For Connecting Circuit Breaker On Pole
                                                                                    
                        
                        
                        
                                                            High Speed Digital Signal Processing System For Connecting Circuit Breaker On Pole
                                                    
                        
                     Wireless Transmission Power Distribution Terminal Feeder Unit For Circuit Breaker
                                                                                    
                        
                        
                        
                                                            Wireless Transmission Power Distribution Terminal Feeder Unit For Circuit Breaker
                                                    
                        
                     Software Platform Dsp Digital Signal Processor Self Test With Channel Monitor
                                                                                    
                        
                        
                        
                                                            Software Platform Dsp Digital Signal Processor Self Test With Channel Monitor
                                                    
                        
                     High Performance Master Terminal Unit TYHD - DTU Model Communication Solutions
                                                                                    
                        
                        
                        
                                                            High Performance Master Terminal Unit TYHD - DTU Model Communication Solutions
                                                    
                        
                     DTU Real Time Power Distribution Terminal For Data Storage / Recording
                                                                                    
                        
                        
                        
                                                            DTU Real Time Power Distribution Terminal For Data Storage / Recording
                                                    
                        
                     Fast / Stable Rtu Scada Power Systems For Power Circuit Low Power Consumption
                                                                                    
                        
                        
                        
                                                            Fast / Stable Rtu Scada Power Systems For Power Circuit Low Power Consumption
                                                    
                        
                     DTU Power Distribution Feeder For RMU , High Intensity Remote Interface Unit
                                                                                    
                        
                        
                        
                                                            DTU Power Distribution Feeder For RMU , High Intensity Remote Interface Unit