| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Residual Current Circuit Breaker | 
|---|---|
| Brand Name: | NBSE/OEM | 
| Model Number: | NBSL1-100 | 
| Certification: | CE,CB,CCC,RoHS,WEEE | 
| Place of Origin: | CHINA | 
| MOQ: | 100PCS | 
| Price: | Negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 30,000pcs per month | 
| Delivery Time: | 10-20days | 
| Packaging Details: | Export Carton | 
| Poles number: | 2P | 
| Rated Frequency: | 50/60Hz | 
| Rated Voltage: | 240V/415V | 
| Rated Current: | 100A | 
| Leakage Action Current: | 30mA,100mA,300mA | 
| Standard: | IEC61008-1 | 
| Warranty: | 2 YEARS | 
| Breaking Capability: | 6KA/10KA | 
| Type: | Residual Current,Mini,A,Electro-manetic type | 
| Product name: | residual current circuit breaker,RCCB circuit breaker | 
| Application: | Short-circuit Protection,Electrical Power,earth leakage protection | 
| Printing: | Standard or customized | 
NBSe NBSL1-100 Series Residual Current Circuit Breaker,rcd residual current device
1. APPLICATION
NBSL1-100 series residual current circuit breakers are applied to the lines with AC 50/60Hz,rated voltage of230V(1P+N) or 400V(3P+N),and rated current of 100A.In case of electric shock or electric leakage current exceeds the specified value, the residual current circuit breaker can switch off the fault circuit in a very short time, protecting the safety of person and electric equipment.
Can be used in the industrial, commercial, high-rise buildings, civil residences and other places.
2. TECHNICAL PARAMETER
| Technical Parameter | |||
| Spec Parameter | |||
| Rated Operating voltage(Ue) | 230V(1P+N)/400V(3P+N) | ||
| Rated Current(In) | 16,25,32,40,50,63,80,100 | ||
| Tripping Type | Electronic,Electromagnetic | ||
| Characteristic | A type, AC type, S type | ||
| Poles | 1P+N,3P+N | ||
| Rated Frequency | 50/60Hz | ||
| Rated Insulation voltage(Ui) | 500V | ||
| Rated residual current (IΔn) | 10,30,100,300mA | ||
| Rated residual switching on and | 800A | ||
| breaking capacity(IΔm) | |||
| Rated residual short-circuit current | 6000A | ||
| limit(IΔc) | |||
| Rated short-circuit current limit(Inc) | 6000A | ||
| Rated switching on and breaking capaity(Im) | 800A | ||
| Maximun breaking time(IΔm) | 0.3s | ||
| Rated impulse withstand voltage(Uimp) | 6kV | ||
| Mechanical life(times) | >10,000 times | ||
| Standard Certificate | |||
| Comply with Standard | IEC 61008 | ||
| GB 16916 | |||
| Certificate | CE, CB, RoHS,WEEE | ||
| Working Envirnment | ||
| Humidity | 40℃ humidity notexceed 50% 20℃ humidity not exceed 90% | |
| (Condensation on the product due to | ||
| Working Temperature | -5℃~+40℃ and its average over aperiod of 24h does not exceed | |
| Magnetic field | No more than 5 times the geomagnetic field | |
| Pollution level | 2 | |
| Altitude(m) | 2000 | |
| Mounting and Wiring | ||
| Shock and vibration | Should be installed in the case of no obvious impact vibration | |
| Installation category | Ⅲ | |
| Terminal connection types | type cable,type U bus, TH 35mm Din-rail | |
| Wiring terminal connection conductor | 1.5~25 mm² | |
| Wiring terminal copper size | 25 mm² | |
| Tightening torque | 3.5N*m | |
| Installation mode | UsingTH35-7.5 profile installation, the title of | |
| Wiring incoming mode | upper and lower incoming is possible for ELM type, | |
3. OPERATION PRINCIPLE FIG.

4. DIMENSION DIAGRAM

5. WORKING PRINCIPLE

Company and Service
located in Wenzhou,Zhejiang is an important economic center in
South Gulf Coast, Registered trade mark is “NBSe”.
As one of the top supplier of electrical appliances, We focus on
the field of low voltage appliances power distribution,electrical
equipment and Industrial automation equipment.
Main products: circuit breaker, moulded case circuit breaker, Isolator switch,contactor,Thermal relay, electrical meter, distribution box, etc.
Quality &Standards:Products are producted per ISO9001:2008, IEC60947, IEC60898,CB, SAA, TUV,CE,NOM,ROHS,PCT, CCC etc.
Business strategies &Characristic: Quality,Honesty and technological innovation are the corner
stones of our company's business strategy.
We are trying to develop NBSe into a world-class Electrical
manufacturer.
FAQ:
Q1: What's your product Range?
A.
- Shell Unti-fire. nylon pa66 or not unti-fire.
- Parts, Copper or iron
- Point Sliver point or Copper point
Q2: Are you a manufacturer?
A. Yes, we are only produce the circuit breaker over 20 years from 1999.
Q3: Do you have stock products to sell?
A. No,we work on OEM orders, The means, material, quantity,packing
solution,etc will depend on your requests.obviously, your logo can
be printed on the products.
Q4. what's the payment term?
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q5. how's the delivery time ?
A. usually it will take about 30 days for 30000pcs
Q6. tell me the standard of package?
A. Normally are cartons, color box or white box
Q7. what kind of material of circuit breaker?
A. we have two types, one copper coil with silver point and the
other is brass coil with copper point. It depends on your
requirement. In fact, those two have no difference if normal work
well. Only except the electrical life. Copper and silver is better
and also higer price.
Q8. We want to know month capacity.
A. 400,000pcs/month
Q9. Where is your market?
A. Our products are popular in Western Europe, Middle-East, Afirca, South Asia ,South Ameirca
countries and area. Some of them are our regular customers and some of them are
developing. We hope you can join us and make mutural benifit from
our cooperation.
Q10. what kind of certificate you have ?
A. CE, CB,CCC,ISO9000.
Q11. Do you inspect the finished products
A. Yes.Each step of products will be inpected by QC department
before shipping.
Q12. How are you ship the finished products?
- By Sea
- By plane
- By counties,TNT, DHL,FEDEX,UPS.etc.
|   | 
 NBSe DZ47LE Differential Circuit Breaker, overcurrent circuit breaker
                                                                                    
                        
                        
                        
                                                            NBSe DZ47LE Differential Circuit Breaker, overcurrent circuit breaker
                                                    
                        
                     100mA / 300mA Residual Current Circuit Breaker RCCB IEC61008-1 Standard
                                                                                    
                        
                        
                        
                                                            100mA / 300mA Residual Current Circuit Breaker RCCB IEC61008-1 Standard
                                                    
                        
                     Bf62 Series Residual Current Breaker With Overload Protection RCD Switch
                                                                                    
                        
                        
                        
                                                            Bf62 Series Residual Current Breaker With Overload Protection RCD Switch
                                                    
                        
                     NBSe Residual Current Circuit Breaker 100A Type A RCD NBSL1-100 Series
                                                                                    
                        
                        
                        
                                                            NBSe Residual Current Circuit Breaker 100A Type A RCD NBSL1-100 Series
                                                    
                        
                     NBSe ID Series Residual Circuit Breaker With Overload Earth Leakage Protection
                                                                                    
                        
                        
                        
                                                            NBSe ID Series Residual Circuit Breaker With Overload Earth Leakage Protection
                                                    
                        
                     RCCB 4P Residual Current Circuit Breaker BFL64 Series DIN Rail Mounting Type
                                                                                    
                        
                        
                        
                                                            RCCB 4P Residual Current Circuit Breaker BFL64 Series DIN Rail Mounting Type
                                                    
                        
                     BF60 Series Residual Current Protective Device High Short Circuit Capacity
                                                                                    
                        
                        
                        
                                                            BF60 Series Residual Current Protective Device High Short Circuit Capacity
                                                    
                        
                     NBSe BF62 Series Residual Current Circuit Breaker Short Circuit Protection
                                                                                    
                        
                        
                        
                                                            NBSe BF62 Series Residual Current Circuit Breaker Short Circuit Protection
                                                    
                        
                     BFL62 Series Double Pole Circuit Breaker , MCB RCD Circuit Breaker Lightweight
                                                                                    
                        
                        
                        
                                                            BFL62 Series Double Pole Circuit Breaker , MCB RCD Circuit Breaker Lightweight
                                                    
                        
                     NBSL1-100 Series Residual Current Circuit Breaker With Overcurrent Protection
                                                                                    
                        
                        
                        
                                                            NBSL1-100 Series Residual Current Circuit Breaker With Overcurrent Protection