| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Adjustable Load Bank | 
|---|---|
| Brand Name: | Kaixiang | 
| Model Number: | AC400V-1250kvA | 
| Certification: | ISO9001 | 
| Place of Origin: | China | 
| MOQ: | 1 set | 
| Price: | negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 80 Sets / Month | 
| Delivery Time: | Within 42 working days | 
| Packaging Details: | Packaged in wooden cases | 
| Model: | AC400V-1250KVA | 
| Rated power: | 1250 KVA | 
| Casing Color: | Grey(RAL7035)or as required | 
| Display Precision: | 0.5 class | 
| Relative Humidity: | ≤95% | 
| Max Protection Grade: | IP21 | 
AC400V-1250kvA Adjustable Load Bank With Frequency 60 HZ In High Performance
Introduction
Adjustable Load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
AC400V-1250kvA Adjustable Load Bank can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application.
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket base, castors. Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.
Application
1. factory testing of engine generator sets
2. To reducewet stacking problems
3. Periodic excercising of stand-by engine generator sets
4. Ups system testing
5. Battery system testing
6.Load optimization in prime power applications
7. Factory testing of turbines
Technical specification
| System Parameter | |
| Rating voltage/frequency | 400V, 3 phase 4 wire 60Hz | 
| Max Load Power | Apparent Power: 1250KVA Resistive Load: 1000kW Inductive Load: 750KVAR | 
| Load Resolution | Resistive Load: 13 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW Inductive Load: 13 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 50KVAR, 100KVAR,100KVAR,200KVAR,200KVAR | 
| Power Factor | 0.8(lag) | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance (overall) | ±3% | 
| Fan &Control Voltage | External AC 3 phase 4 line, 400V/50Hz | 
| Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar | 
| Communication Interface | RS485,RS232 | 
| Insulation | F | 
| Max Protection Grade | IP54 | 
| Duty Cycle | Continuous | 
| Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling | 
| Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door | 
| Internal Lighting | Adequate internal lighting will be provided | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Color | Grey RAL7035 or as required | 
| Dimensions | 4000mm×2350mm×2591mm(L×W×H) | 
| Operating Environment Parameter | |
| Workplace | Outdoor | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Atmospheric Pressure | 86~106kPa | 
| Brands of Main Components | |
| Contactor | Schneider | 
| Fuse | Miro | 
| PLC | Siemens | 
| Alloy Resistor | Kaixiang | 
| Data Processing Software | Kaixiang | 
2. Users can set adjustable discharge power according to capability parameter and test request.
3. Voltage and current value can be displayed with multi-functional digital meter.
4. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
5. Two or more Intelligent AC Load Bank can operate in parallel.

|   | 
 510 KW Multi Voltage Inductive Load Bank 60 HZ Frequency With Remote Control
                                                                                    
                        
                        
                        
                                                            510 KW Multi Voltage Inductive Load Bank 60 HZ Frequency With Remote Control
                                                    
                        
                     1010 KW Power Portable AC Load Bank 3 Phase 4 Wire With Force Air Cooling
                                                                                    
                        
                        
                        
                                                            1010 KW Power Portable AC Load Bank 3 Phase 4 Wire With Force Air Cooling
                                                    
                        
                     1000 KVA Adjustable Load Bank , Grey Resistive Load Bank With Hanging Ring
                                                                                    
                        
                        
                        
                                                            1000 KVA Adjustable Load Bank , Grey Resistive Load Bank With Hanging Ring
                                                    
                        
                     400 V 1200 KW Adjustable Load Bank Continuous Working For Generator Test
                                                                                    
                        
                        
                        
                                                            400 V 1200 KW Adjustable Load Bank Continuous Working For Generator Test
                                                    
                        
                     Programmable Ac Load Bank 1000 KVA Variable Resistive With 3 Phase
                                                                                    
                        
                        
                        
                                                            Programmable Ac Load Bank 1000 KVA Variable Resistive With 3 Phase
                                                    
                        
                     High Efficiency Ac Electronic Load , Resistive Load Bank Testing For Generator 600 KW
                                                                                    
                        
                        
                        
                                                            High Efficiency Ac Electronic Load , Resistive Load Bank Testing For Generator 600 KW
                                                    
                        
                     300 KW Electrical Load Testing Equipment , Programmable Ac Load Bank
                                                                                    
                        
                        
                        
                                                            300 KW Electrical Load Testing Equipment , Programmable Ac Load Bank
                                                    
                        
                     50 HZ Adjustable Load Bank , Resistive Load Box For Thailand Generator UPS
                                                                                    
                        
                        
                        
                                                            50 HZ Adjustable Load Bank , Resistive Load Box For Thailand Generator UPS
                                                    
                        
                     Electrical Adjustable Load Bank 3 Phase 4 Wire Ups Load Bank Testing
                                                                                    
                        
                        
                        
                                                            Electrical Adjustable Load Bank 3 Phase 4 Wire Ups Load Bank Testing
                                                    
                        
                     Durable Adjustable Load Bank 1200kw For Generator Ups Transformer Testing
                                                                                    
                        
                        
                        
                                                            Durable Adjustable Load Bank 1200kw For Generator Ups Transformer Testing