| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Single Phase Energy Meter Test Bench | 
|---|---|
| Brand Name: | SHENGDI TECHNOLOGY | 
| Model Number: | HS6103 | 
| Certification: | GS,CNAS | 
| Place of Origin: | ZHEJIANG,CHINA | 
| MOQ: | 1 SET | 
| Price: | USD$1~100000/SET | 
| Payment Terms: | TT,LC | 
| Supply Ability: | 50 SETS/35 DAYS | 
| Delivery Time: | 35~45days | 
| Packaging Details: | WOODEN CASE | 
| Accuracy: | 0.05% Class | 
| Positions: | 3~60Positions | 
| Current: | Max.120A | 
| phases: | 1 phase | 
| Company Info. | 
| Zhejiang Shengdi Technology Inc. | 
| View Contact Details | 
| Product List | 
HS-6103 Single-phase energy meter test bench.
This Bench Comprises of PWM power source,standard digital energy
meter,error processor,and PC processing software.Can test 3-60 Variors Energy Meter.
Technical Parameters:
1.Accuracy Class:0.05/0.1/0.2 %
2.Standard Energy meter: HS-5100 Single-Phase Wide-measurement-range Energy Meter,Accuracy
class:0.05/0.1/0.2 ; Multi-path Voltage transformer: Accuracy
class:0.01. Rated load per path: 10 VA
3.Voltage Range(V): 220V(240V Option) Output Range:
0~125%,Resolution:0.01% full range
4.Current Range(A):0.1 ~100A(200A option) Output
Range:0~120%,Resolution:0.0001A(Min)
5. Phase Angle:0~360.Resolution of phase angle setting:0.01
6. Frequency: 45Hz ~65Hz,Resolution:0.01Hz
7.Output waveform distortion:Both Voltage and Current 0.5%
8.Output Voltage,current and power stability: 0.05% /3min
9.Output Capacity:
Current: 1000VA(120A)
Voltage: 400 VA(24 meter testing stations)
If the number of energy meter to be tested is increased whenever
necessary,its maximum load may be extended to current:1800VA, and Voltage:1000VA
10.Load Characteristics: Resistive,inductive and Capacitive(less
than 4uF)
11.Starting current output:5mA(Min);Accuracy:5%;Starting
power:Accuracy 5%
12.Test Stations: 24/48 (Standard), also 3-60 option.
13.Testing function: Accuracy testing,Creep testing,Starting up
testing,Harmonic testing,repeatability testing,influencing
testing,dial testing etc.
14.Input power supply:220V AC 10%,50Hz;Max power
consumption:1500VA(24 energy meter testing stations)
15. RS485/Rs-232
16. GPS timing system, HS-1012 standard clock(Option)
| No. | Description | Parameters | 
| 1 | Phases | 1 phase/single-phase | 
| 2 | Accuracy | 0.05%,0.1% | 
| 3 | Current output | Max.120A. | 
| 4 | Position | 3~60 meters | 

QUICK CONNECTOR(SINGLE LOOP)

REFERENCE METER (HS-5100)



|   | 
 Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                                                    
                        
                        
                        
                                                            Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                    
                        
                     12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                    
                        
                     12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                    
                        
                     12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                                                    
                        
                        
                        
                                                            12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                    
                        
                     48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                                                    
                        
                        
                        
                                                            48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                    
                        
                     Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                                                    
                        
                        
                        
                                                            Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                    
                        
                     Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                                                    
                        
                        
                        
                                                            Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                    
                        
                     HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                                                    
                        
                        
                        
                                                            HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                    
                        
                     Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                    
                        
                     HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range