| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Closed Cooling Tower | 
|---|---|
| Brand Name: | YCT/YAT/CLA/CLB/YKH | 
| Model Number: | YANYE /JIANGFAN/BAOFENG | 
| Certification: | ISO9001:2008/CTI ON SITE | 
| Place of Origin: | SHANGHAI/WUXI | 
| MOQ: | I UNIT | 
| Price: | negotiation | 
| Supply Ability: | 340 unit /month | 
| Delivery Time: | 58 days | 
| Packaging Details: | WITHOUT PACKAGE FOR CONTAINER OCEAN TRANSPORT | 
| Cooling Coils: | High-quality seamless 316L SS Coils | 
| Shell: | 304 SS steel plate | 
| Control Panel: | Schneider Brand | 
| Power Supply: | 380v/3p/50hz | 
| Fan: | Motor grade: IP55; Insulation: F; Alum-alloy blades; Axial Flow | 
| Temperature controller: | Standard | 
| Spray Nozzles: | ABS basket nozzles of umbrella style | 
| spare parts: | as per condition | 
| Warranty period: | 32 month | 
| Electrical Brandname: | Simens | 
Standard Closed Loop Cooling Tower 1635kw Heat Reject For Industrial Architecture
Description
1.closed cooling towers are Using the counter flow cooling way; few
cooling blind area, high thermal efficiency:
2. Efficiency of cooling tower is to adopt the professional and
efficient water collector to control the running floating rate
,that is less or equal to 0.001%;
3.Closed cooling tower in high air duct design to make sure the
equipment to meet the demand of cooling air flow rate during
operation;
4. Reduce the occupied area compare to other types of cooling tower
to meet the users' space demanding;
5.The tank of cooling tower adopts closed loop, eliminate clutters
go into the tower body to produce spraying blocked;
6.The important part of counterflow cooling tower is the cooler
that uses the antifreeze energy-saving design, to ensure the
circulating water drain up and avoid freezing in the northern
region with low temperature;
7.Design two-circuit cycle according to the demands of custom's
devices, even if one circulation failure, anther cycle can be still
normally operating;
8.The cooling tower design of units are elegant appearance,
automatic digital display, easy to maintain.
Item
| FBN-300T Specifications | |
| Heat Reject | 1635kw | 
| Nominal Flow Rate | 300 m3/h | 
| Work Flow Rate | 235 m3/h | 
| Fan Power | 2×11kw | 
| Wind Flow Rate | 2×120000m3/h | 
| Spray Pump Power | 7.5kw | 
| Spray Water Flow Rate | 172m3/h | 
| Spray Pump Raise | 9.6m | 
| Inlet/Outlet Diameter | DN 200mm | 
| Makeup Connection | DN40 (Please specify adopted screw standards) | 
| Bleed Line Diameter | DN50 (Please specify adopted screw standards) | 
| Net Weight | 5150kg | 
| Operate Weight | 9500kg | 
| Dimensions | 5100×2300×4950mm | 
The biggest difference between closed cooling tower and open cooling tower: The closed cooling tower will be cooled by the cooling medium through the coil and the cooling water and air outside the tube,formed a closed loop system, to avoid the cooling medium due to contact with air and lead to pollution, resulting in a waste of the cooling medium, equipment congestion and other failures affect the normal use. This equipment is suitable for use in harsh environments such as drought, water shortage and dust storms. It can be used in central air conditioning, instrumentation, metallurgical intermediate frequency electric furnace, converter, power plant generating units, steam turbine nuclear power plant, substation, chemical, pharmaceutical, welding, rolling aluminum, copper foil cooling oil, large hydraulic machinery hydraulic Oil and other industrial manufacturing use.
|   | 
 Eco Friendly Closed Cooling Tower System For Glass Manufacturing Industry
                                                                                    
                        
                        
                        
                                                            Eco Friendly Closed Cooling Tower System For Glass Manufacturing Industry
                                                    
                        
                     Anti Corrosion Industrial Water Cooling Towers , Forced Cooling Tower Easy Installation
                                                                                    
                        
                        
                        
                                                            Anti Corrosion Industrial Water Cooling Towers , Forced Cooling Tower Easy Installation
                                                    
                        
                     Large Capacity Closed Cooling Tower , Induced Draft Counterflow Cooling Tower
                                                                                    
                        
                        
                        
                                                            Large Capacity Closed Cooling Tower , Induced Draft Counterflow Cooling Tower
                                                    
                        
                     Durable Commercial Cooling Tower , Closed Loop Water Cooling System ISO 9001 Approved
                                                                                    
                        
                        
                        
                                                            Durable Commercial Cooling Tower , Closed Loop Water Cooling System ISO 9001 Approved
                                                    
                        
                     Easy Operation Closed Cooling Tower System 380v 3p 50hz For Refrigeration
                                                                                    
                        
                        
                        
                                                            Easy Operation Closed Cooling Tower System 380v 3p 50hz For Refrigeration
                                                    
                        
                     Small Space Occupancy Closed Cooling Tower With 235 M3/H Work Flow Rate
                                                                                    
                        
                        
                        
                                                            Small Space Occupancy Closed Cooling Tower With 235 M3/H Work Flow Rate
                                                    
                        
                     Portable Industrial Cooling Tower , Closed Cycle Cooling Water System ISO 9001 Approved
                                                                                    
                        
                        
                        
                                                            Portable Industrial Cooling Tower , Closed Cycle Cooling Water System ISO 9001 Approved
                                                    
                        
                     Industrial BAC Closed Cooling Tower 172m3/h Spray Water Flow Rate 32 Month Warranty
                                                                                    
                        
                        
                        
                                                            Industrial BAC Closed Cooling Tower 172m3/h Spray Water Flow Rate 32 Month Warranty
                                                    
                        
                     Energy Saving Closed Cooling Tower With Seamless 316L SS Cooling Coils
                                                                                    
                        
                        
                        
                                                            Energy Saving Closed Cooling Tower With Seamless 316L SS Cooling Coils
                                                    
                        
                     copper cooler, copper tube,closed fluid cooler
                                                                                    
                        
                        
                        
                                                            copper cooler, copper tube,closed fluid cooler