| Sign In | Join Free | My chinacomputerparts.com |
|
| Categories | Aluminum Single Point Load Cell |
|---|---|
| Brand Name: | inntronic |
| Model Number: | ISP4MC3 |
| Place of Origin: | China |
| MOQ: | 1pc |
| Payment Terms: | L/C |
| Delivery Time: | 15-30 days |
| Price: | Negotiable |
| Type: | Single Point Load Cell |
| Capacity: | 0.3kg 0.5kg 2kg 3kg |
| Output: | 2mv/v |
| Material: | Aluminum |
| Application: | electronic balance |
| Interchangeable brand: | HBM |
| IP Protection standard: | IP67 |
| Accuracy grade: | C3 |
| Hysteresis error (dhy)3): | ±0.0150 |
| Non-linearity (dlin)3): | ±0.0150 |
| Company Info. |
| Innovation Electronic Co.,Ltd |
| View Contact Details |
| Product List |
Small Size Low Capacity Load Cell Shielded Connection Cable For Electronic Balance
Good quality and long life
− For determining small masses − Small size − Accuracy class C3 with OIML- R60 test report − Off center load compensated − Degree of protection IP65 according to IEC 529 − Shielded connection cable |
| Type | IPW4MC3 | |||||||
| Order-No. | 1-PW4C3/300G-1 | 1-PW4C3/500G-1 | 1-PW4C3/2KG-1 | 1-PW4C3/3KG-1 | ||||
| Accuracy class1) | C3 | |||||||
| Number of load cell intervals (nLC) | 3000 | |||||||
| Maximum capacity (Emax)2)) | g/kg | 300 | 500 | 2 | 3 | |||
| Minimum LC verification interval (vmin) | g | 0.05 | 0.1 | 0.2 | 0.5 | |||
Temperature effect on zero balance (TK0) | % v. Cn / 10 K | 0.0233 | 0.0280 | 0.0140 | 0.0233 | |||
| Max. platform size | mm | 800 x 800 | ||||||
| Sensitivity (Cn) | mV/V | 1.0±0.1 | 2.0±0.2 | |||||
| Zero balance | 0±0.1 | |||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K % of Cn | ±0.0175 ±0.0117 | ||||||
| Hysteresis error (dhy)3) | ±0.0150 | |||||||
| Non-linearity (dlin)3) | ±0.0150 | |||||||
| Minimum dead load output return (DR) | Ω | ±0.0245 | ||||||
| Off center load error4) | ±0.0233 | |||||||
| Input resistance (RLC) | 380±38 | |||||||
| Output resistance (R0) | 380±38 | |||||||
| Reference excitation voltage (Uref) | V | 5 | ||||||
| Nominal range of excitation voltage (BU) | 15 | |||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | ||||||
| Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | ||||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | |||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | |||||||
load limit (EL ) at max. 100mm eccentricity | % of Emax % of Emax | 150 100 | ||||||
| Lateral load limit (Elq), static | 200 | |||||||
| Breaking load (Ed) | >300 | |||||||
| Deflection at Emax (snom), approx. | mm kg | < 0.4 | ||||||
| Weight (G), approx. | 0.07 | |||||||
Protection class according to EN 60 529 (IEC 529) | IP67 | |||||||
Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC | |||||||





|