| MOQ: | 1set | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 36,000,00pcs per year | 
| Delivery Time: | Within 7 days | 
| Packaging Details: | Carton packing for one sets, one set including three piece with Components | 
| Type: | Clamp-on Current Transformer | 
| Feature: | Simple and quick installation in small space | 
| Ampere: | 500A | 
| Application: | General measurement | 
| Characteristic: | Excellent linearity | 
| Company Info. | 
| Shenzhen Chuangyin Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
100-3000A 50/60Hz Clamp-on Current Transformer Current Transformer / Open type CY-QCT01
1.Product Introduction:
QCT04-12'clamp-on current transformer is easily installed in small
spaces (measurement environment) and no need to remove the main
busbar or cable. It complys with the CE standard and meets the 300V
CAT III safety grade.
Feature:
1. Flexible and light weight, pretty appearance
2. Simple and quick installation in small space
3. Excellent linearity
4. Maximum measured current is 130A
General Data:
Operating temperature & humidity: 0 - 500C (32 - 122 0 F), _<
80% RH (no condensate)
Storage Temperature & Humidity: -10 - + 600C (14 -140 0 F), <_
80% RH (no condensate)
Operating environment: indoor, up to 2000 meters above sea level.
Safety level standards: IEC 61010-1: 2001. 300 V CAT III
Application:
General measurement and protection for strong mobility or
space-constrained or uninterrupted power
systems.
Power instrumentation, electronic multi-function energy meter and
field calibrator, instrumentation measurement and protection.
Dimension And Schematic:


Usage Instruction:

Attention:
1. Please note that prolonged over current use may damage the
product.
2. Do not store or use this product in the environment of directly
exposed to sunlight, high temperature or high
humidity or condensation. The product may be damaged, the
insulation will be deteriorated in these
condition.
3. Do not drop the product or avoid other mechanical shocks, which
may damage the surface of the core
and affect the measurement accuracy.
4. Keep the jaws & the core slit without other outer matter, which
may affect the clamping action.
5. Holding Clamp Closed When storage, in order to avoid dust or
dirt buildup on the core engagement surface,
other outer maters may affect the measurement performance.
6. When disconnecting the BNC connector, be sure to rotate the lock
before releasing the connector. Pulling the
connector or pulling the cable (under lock unreleased) will damage
the connector.
7. To prevent damage to the connected instrument, do not connect or
disconnect the sensor in the event of
charging (working statue) .
8. Note: Only one wire can be clamped in the center of the chuck.
If you clamp the single-phase (2-wire) or
three-phase (3-wire) cable at the same time, the device will not
generate any readings.
9. The above parameters are only for reference as typical data,
customer-made is subject to customer's request.
|   | 
 Wireless - Single - Phase AC Split Core Current Transformer ON Energy Consumption Sensor
                                                                                    
                        
                        
                        
                                                            Wireless - Single - Phase AC Split Core Current Transformer ON Energy Consumption Sensor
                                                    
                        
                     Split Core Zero Sequence Current Transformer Ring Type For Flexible Steel Strips
                                                                                    
                        
                        
                        
                                                            Split Core Zero Sequence Current Transformer Ring Type For Flexible Steel Strips
                                                    
                        
                     500A 50/60Hz Open type Split Core Current Transformer Smart Logger
                                                                                    
                        
                        
                        
                                                            500A 50/60Hz Open type Split Core Current Transformer Smart Logger
                                                    
                        
                     Open Smart Grid Split Core Current Transformer Small Size 75-600A
                                                                                    
                        
                        
                        
                                                            Open Smart Grid Split Core Current Transformer Small Size 75-600A
                                                    
                        
                     Open Current Transformer Low Consumption With Magnetic 50-300A
                                                                                    
                        
                        
                        
                                                            Open Current Transformer Low Consumption With Magnetic 50-300A
                                                    
                        
                     400A Split Core Current Transformer Open Separated Coil Low Consumption
                                                                                    
                        
                        
                        
                                                            400A Split Core Current Transformer Open Separated Coil Low Consumption
                                                    
                        
                     High Permeability Core Current Transformer Split Clamp On / Open Light Delicate Exquisite
                                                                                    
                        
                        
                        
                                                            High Permeability Core Current Transformer Split Clamp On / Open Light Delicate Exquisite
                                                    
                        
                     Clamp On Split Core Current Transformer Open Distributed Measurement Systems
                                                                                    
                        
                        
                        
                                                            Clamp On Split Core Current Transformer Open Distributed Measurement Systems
                                                    
                        
                     100-600A 50Hz Split Core Ac Current Sensor Transformer / Open Type Foot Or Busbar Mounted
                                                                                    
                        
                        
                        
                                                            100-600A 50Hz Split Core Ac Current Sensor Transformer / Open Type Foot Or Busbar Mounted
                                                    
                        
                     100A/40mA Split Core Current Transformer Open type CT CY-KCT01
                                                                                    
                        
                        
                        
                                                            100A/40mA Split Core Current Transformer Open type CT CY-KCT01