| Sign In | Join Free | My chinacomputerparts.com | 
 | 
| Categories | Wastewater Flow Meter | 
|---|---|
| Brand Name: | Iflow | 
| Model Number: | YF-E1000-5 | 
| Certification: | ISO9001, CE | 
| Place of Origin: | China | 
| MOQ: | negotiable | 
| Price: | negotiable | 
| Payment Terms: | T/T, L/C | 
| Supply Ability: | 2200000 units per year | 
| Delivery Time: | 4-6 weeks | 
| Packaging Details: | wooden case pluse pallet | 
| Type: | Electromagnetic flowmeter | 
| Connect port: | Flange | 
| Pressure rating: | PN16, PN25, PN40 Mpa | 
| Electrode: | 316L / Hasteeloy-C / Ti / Ta / Pt100 | 
| Measure: | flow and heat | 
| Protection: | IP68 | 
| Accuracy: | 0.25% , 0.5% | 
| Power supply: | 85 - 265V AC / 8-36V DC | 
sewage flow meter by open channel ultrasonic flow meter Parshall 9000 cbm/hour
Technical Advantages
The magnetic flowmeter does not obstruct flow, so it can be applied to clean, sanitary, dirty, corrosive and abrasive liquids. Magnetic flowmeters can be applied to the flow of liquids that are conductive, so hydrocarbons and gases cannot be measured with this technology due to their non-conductive nature and gaseous state, respectively.
Electromagnetic flowmeters do not require much upstream and downstream straight run so they can be installed in relatively short meter runs. Magnetic flowmeters typically require 3-5 diameters of upstream straight run and 0-3 diameters of downstream straight run measured from the plane of the magnetic flowmeter electrodes.
Product Description
This remote electromagnetic flow meters are designed for measurement of conductive liquids. The magmeters have no moving parts and a PTFE lining, they can handle applications involving wastewater, pulp, food, and slurries. Standard outputs include analog, frequency, and RS485 communications. Optional sanitary tri-clamp mounting allows use of our flow meters in applications not previously open to magmeters. Local- and remote-display models are available.
Accuracy
| Pipe Dia (mm) | Velocity (m/s) | Accuracy | 
| 3-20 | <0.3 | + 0.25% FS | 
| 0.3-1 | + 1.0% Readout | |
| 1-15 | + 0.25% Readout | |
| 25-600 | 0.1-0.3 | + 0.25% FS | 
| 0.3-1 | + 0.5% Readout | |
| 1-15 | + 0.3% Readout | |
| 700-3000 | <0.3 | + 0.25% FS | 
| 0.3-1 | + 1.0% Readout | |
| 1-15 | + 0.25% Readout | 
Grounding
From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.
Technical data
| Product name | Electromagnetic flowmeter | ||
| Product type | Local|compact display | Remote display | Signal converter | 
| Model | IYF-E | IYF-F | IRT | 
| Pipe Diameter (mm) | DN10-DN2000 | ||
| Power supply | 100-240 VAC / 18-36 VDC | ||
| Accuracy | + 0.5% | + 0.5% | + 0.5% | 
| Power consumption | <6w | <6w | <6w | 
| Enclosure rating | IP65 | IP68 | IP65 | 
| Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ | 
| Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ | 
| Relative humidity | 10-90% | 10-90% | 10-90% | 
| Meter ratio | 1:100 | 1:100 | 1:100 | 
| Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow | 
| Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet | 
| Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 
Features
Model selection
Applicable metering liquid:
Non-applicable metering medial
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted
in different locations, it’s suggested to select
remote type in the following conditions:
| I | Model | ||||||||
| YF | Electromagnetic flowmeter | ||||||||
| TF | Turbine | ||||||||
| VF | Votex | ||||||||
| LX | Vane wheel | ||||||||
| T | Ultrasonic | ||||||||
| E/F display mode | E: compact/local display, F: remote display | ||||||||
| Pipe Dia | Type (mm) | ||||||||
| xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
| Code | Accuracy | ||||||||
| 1 | + 0.5% FS | ||||||||
| 2 | + 1.0% FS | ||||||||
| 3 | + 0.2% FS | ||||||||
| Code | Type | ||||||||
| N | Converter: 12 / 24 VDC, pulse output | ||||||||
| A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
| B | Intelligent, Lion battery, no local display | ||||||||
| G | Smart, local display, 4-20mA output | ||||||||
| C1 | Smart, local display, RS485 | ||||||||
| C2 | Smart, local display, HART | ||||||||
| Code | Type | ||||||||
| S | Carbon steel housing | ||||||||
| L | Stainless steel housing | ||||||||
| G | High pressure housing | ||||||||
| HL | 316L electrode | ||||||||
| HTi | Titanium electrode | ||||||||
| HTa | Tantlum electrode | ||||||||
| HC | Hastelloy-C electrode | ||||||||
| L1 | Liquid media | ||||||||
| L2 | Gas media | ||||||||
| P | Pressure compensation | ||||||||
| T | Temperature compensation | ||||||||
| PT | Pressure&Temp. Compensation | ||||||||
| F | PTFE liner | ||||||||
| X | Rubber liner | ||||||||
| Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner | |||||||||
Pipe Diameter, flow volume and product dimension
| Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
| (mm) | Normal | Min | Max | L | D | H | H1 | 
| 15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 | 
| 20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
| 25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
| 32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
| 40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
| 50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 | 
| 65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
| 80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
| 100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 | 
| 125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
| 150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 | 
| 200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 | 
| 250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 | 
| 300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 | 
| 350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
| 400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 | 
| 450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 | 
| 500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 | 
| 600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
| 700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 | 
| 800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 | 
Industrial applications
| Chemical | Food & beverage | Paper mill | 
| Metallurgy | Environment protection | Hydraulic | 
| Mining | Stainless | Petroleum | 
| Pharmacy | Air conditioner | Effluent treatment plant | 
| Seawater desalination | Pharmacy | Water treatment | 
Competitive advantage
Process control

Calibration equipment

|   | 
 Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter
                                                                                    
                        
                        
                        
                                                            Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter
                                                    
                        
                     Pn16mpa Wastewater Flow Meter Hard Rubber Liner For Sewage Flow Metering
                                                                                    
                        
                        
                        
                                                            Pn16mpa Wastewater Flow Meter Hard Rubber Liner For Sewage Flow Metering
                                                    
                        
                     Sewage Flow Metering Magnetic Water Meter Hard Rubber Liner With Electrode 316l
                                                                                    
                        
                        
                        
                                                            Sewage Flow Metering Magnetic Water Meter Hard Rubber Liner With Electrode 316l
                                                    
                        
                     Electromagnetic Wastewater Flow Meter Ip68 Protection For Flow And Heat Measurement
                                                                                    
                        
                        
                        
                                                            Electromagnetic Wastewater Flow Meter Ip68 Protection For Flow And Heat Measurement
                                                    
                        
                     Sewage Turbine Type Flow Meter Rs485 Standard In Low Viscosity Fluid Metering
                                                                                    
                        
                        
                        
                                                            Sewage Turbine Type Flow Meter Rs485 Standard In Low Viscosity Fluid Metering
                                                    
                        
                     Sewage / Wastewater Flow Meter Magnetic Dn50-1200 Mm With Hard Rubber Liner
                                                                                    
                        
                        
                        
                                                            Sewage / Wastewater Flow Meter Magnetic Dn50-1200 Mm With Hard Rubber Liner
                                                    
                        
                     Payable Sewer Flow Meter Pressure Pn16 , Remote Display Electromagnetic Flow Meter
                                                                                    
                        
                        
                        
                                                            Payable Sewer Flow Meter Pressure Pn16 , Remote Display Electromagnetic Flow Meter
                                                    
                        
                     Turbine Wastewater Flow Meter Flange Port Connection For Effluent Discharge Monitor
                                                                                    
                        
                        
                        
                                                            Turbine Wastewater Flow Meter Flange Port Connection For Effluent Discharge Monitor
                                                    
                        
                     Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700
                                                                                    
                        
                        
                        
                                                            Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700
                                                    
                        
                     High Accuracy Vortex Wastewater Flow Meter With Flanges Port Connection
                                                                                    
                        
                        
                        
                                                            High Accuracy Vortex Wastewater Flow Meter With Flanges Port Connection