Categories | Xenon Test Equipment |
---|---|
Brand Name: | ZONSKY |
Model Number: | ZY6074-ZN1 |
Certification: | ISO9001:2008, CE, SGS, IAF |
Place of Origin: | DONGGUAN, CHINA |
MOQ: | 1 Set |
Price: | Negotiable |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 5 Set / Month |
Delivery Time: | 10 Working Days |
Packaging Details: | Plywood Box |
Standards: | ASTM D 2565 |
External Dimension: | 1050 x 1050 x 1750 MM |
Material: | Baking Finish |
Warranty: | 12 Months |
Humidity Deviation: | ± 2.5% R.H |
Humidity Range: | 30 ~ 98% R.H |
Company Info. |
ZONSKY INSTRUMENT CO.,LTD |
View Contact Details |
Product List |
Xenon Weathering Test Chamber / Xenon Weathering Tester
I. Application
Xenon lamp test chamber uses xenon arc lamp which can simulate all
sunlight spectrum to reproduce destructive light wave in different
environment. It can provide corresponding environment simulation
and accelerated test for scientific research, product development
and quality control. Xenon lamp test box can be used to select new
materials, improve existing materials or evaluate the durability of
materials after composition changes in the test, it can be a good
simulation of different environmental conditions, materials exposed
to sunlight changes. Meet the criteria: GB/T16585-1996, GB14522-93,
GB/T16422.3-97, ASTM D2565.
2. Product Features
All spectrum xenon lamp.
A variety of filtering systems are available.
Water spray function.
Relative humidity control.
The air temperature control system of the test chamber.
Irregular shape sample holder.
The original xenon arc lamp imported from the United States.
Installation is easy to use and basically does not require daily maintenance features.
The lifespan of the xenon arc lamp depends on the level of radiation illumination. Generally, the lifespan of the lamp is 1600 hours. Lamp replacement is convenient and quick, and long acting filters provide protection for maintaining the required spectrum.
3. Standards
GB/T16585-1996, GB14522-93, GB/T16422.3-97, ASTM D2565
Comply with GB/T16585-1996, GB14522-93, GB/T16422.3-97 and ASTM
D2565 standards.
4. Temperature and Humidity Operation Control System
Controller: imports programmable full touch 7 inches
Accuracy range: setting accuracy: temperature (±0.1℃), humidity
(±2% R.H), indicating accuracy: temperature (±0.1℃), humidity (±1%
R.H)
Temperature and humidity sensor: platinum resistance.PT 100 Omega /
MV
Blackboard temperature: bimetallic blackboard thermometer
The water supply system: humidified by automatic control, and xenon
lamp is used for cooling and circulating water.
Circulatory system: heat resistant and low noise air conditioner
motor. Multi leaf centrifugal wind wheel.
The control system: mainly composed of operation panel, central
controller, various key switches, status indicator lights,
executive electrical appliances and so on.
5. The Working Part of The Test Box
Compressor condensing part:
Refrigeration System: The core of the refrigeration system is the
compressor. In this scheme, we use a French Taikang fully enclosed
compressor to ensure the cooling requirements of the studio.
The design and application of refrigeration system energy
regulation technology, an effective way to ensure the normal
operation of refrigeration units, but also to adjust the energy
consumption and refrigeration capacity of the refrigeration system,
so that the operating costs and failure rate of the refrigeration
system to a more economical state.
Refrigeration evaporator: The evaporator is located in the
interlayer of the air duct at one end of the test box, forced
ventilation by the blast motor, rapid heat transfer.
Cooling mode of cooling system: forced air cooling;
Refrigerant: R404a; (environmental protection refrigerant)
Heating part:
Heating side: direct heating in test box;
Military grade stainless steel finned heating tube is adopted, the
heating rate is steady, and the temperature in the box body can be
kept stable. It has the advantages of corrosion resistance, high
and low temperature resistance, no leakage and easy installation.
First, SSR (solid-state relay) output control, with no noise,
reliable work, long life, strong anti-interference ability, fast
switching speed, small external interference, easy to use and other
advantages;
Rain system:
The rain system is mainly composed of nozzles, solenoid valves,
water supply sources and connecting hoses.
Lighting system:
The lighting system is mainly composed of xenon lamp tube,
lampshade, xenon lamp trigger and various control devices. Xenon
lamp energy compensation is achieved by adjusting the sample frame
distance and adjusting the voltage and current.
Duct system:
The air duct system is located in the interlayer at the back of the
test box, and the inner distributors are heater, blade, evaporator,
PT100 temperature sampling sensor, etc. When the fan rotates at
high speed, the air in the studio is sucked into the air duct from
the upper part, and the heat generated by the heater and the
cooling produced by the evaporator are fully mixed and blown out
from the lower part of the air duct. The air after heat exchange
with the sample in the studio is sucked into the air duct for
mixing and recycling, so as to reach the target temperature. At the
same time, we need to ensure that the temperature and humidity
index of the test chamber is higher.
Refrigeration / dehumidification system:
Select the world famous French "Taikang" full closed industrial
refrigeration compressor. It is mainly used for cooling xenon lamp
tube and constant chamber temperature and reducing indoor humidity.
Humidification part:
Steam generator: steam needed to vaporize water to produce
equipment.
Water level control: solenoid valve control water intake, level
switch control water level, humidifier control and alarm to provide
a signal.
Gas circulation part:
Built-in circulating ducts and fans, use efficient refrigerators
and energy regulation system, through efficient ventilators for
effective heat exchange, to achieve the purpose of temperature
change, by improving the air blast, improve air flow and heating
humidification and air surface cooler heat exchange capacity. The
adjustment of the air adjusting bolt greatly improves the
temperature and humidity uniformity of the test box.